Rohini Vidya Shankar

Rohini Vidya Shankar

Auto-generated profile, based on publicly available information

Rohini Vidya Shankar

School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2017 in Journal of Controlled Release
Verified
Journal Article
Open access
DMDavid X. Medina
David X. Medina
KHKyle T. Householder
Kyle T. Householder
RCRicki Ceton
Ricki Ceton
TKTina Kovalik
Tina Kovalik
JHJohn M. Heffernan
John M. Heffernan
RSRachael W. Sirianni
Rachael W. Sirianni
Understanding of the mechanisms by which systemically administered nanoparticles achieve delivery across biological barriers remains incomplete, due in part to the challenge of tracking nanoparticle fate in the body. Here, we develop a new approach for "barcoding" nanoparticles composed of poly(lactic-co-glycolic acid) (PLGA) with bright, spectrally defined quantum dots (QDs) to enable direct, fluorescent detection of nanoparticle fate with subcellular resolution. We show that QD labeling does not affect major biophysical properties of nanoparticles or their interaction with cells and tissues. Live cell imaging enabled simultaneous visualization of the interaction of control and targeted nanoparticles with bEnd.3 cells in a flow chamber, providing direct evidence that surface modification of nanoparticles with the cell-penetrating peptide TAT increases their biophysical association with cell surfaces over very short time periods under convective current. We next developed this technique for quantitative biodistribution analysis in vivo. These studies demonstrate that nanoparticle surface modification with the cell penetrating peptide TAT facilitates brain-specific delivery that is restricted to brain vasculature. Although nanoparticle entry into the healthy brain parenchyma is minimal, with no evidence for movement of nanoparticles across the blood-brain barrier (BBB), we observed that nanoparticles are able to enter to the central nervous system (CNS) through regions of altered BBB permeability - for example, into circumventricular organs in the brain or leaky vasculature of late-stage intracranial tumors. In sum, these data demonstrate a new, multispectral approach for barcoding PLGA, which enables simultaneous, quantitative analysis of the fate of multiple nanoparticle formulations in vivo.

14 January 2019 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
RSRohini Vidya Shankar
Rohini Vidya Shankar
JCJohn C. Chang
John C. Chang
HHHouchun Harry Hu
Houchun Harry Hu
VKVikram D. Kodibagkar
Vikram D. Kodibagkar

28 October 2018 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
ERElisa Roccia
Elisa Roccia
RSRohini Vidya Shankar
Rohini Vidya Shankar
RNRadhouene Neji
Radhouene Neji
GCGastão Cruz
Gastão Cruz
CMCamila Munoz
Camila Munoz
IDIsabel Dregely
Isabel Dregely

16 February 2017 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
Munish ChauhanMunish Chauhan
Munish Chauhan
RSRohini Vidya Shankar
Rohini Vidya Shankar
NKNeeta Ashok Kumar
Neeta Ashok Kumar
VKVikram D. Kodibagkar
Vikram D. Kodibagkar
RSRosalind Sadleir
Rosalind Sadleir

23 November 2015 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
CACaroline P. Addington
Caroline P. Addington
ACAlex Cusick
Alex Cusick
RSRohini Vidya Shankar
Rohini Vidya Shankar
SAShubhangi Agarwal
Shubhangi Agarwal
SSSarah E. Stabenfeldt
Sarah E. Stabenfeldt
VKVikram D. Kodibagkar
Vikram D. Kodibagkar

21 April 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
RSRohini Vidya Shankar
Rohini Vidya Shankar
ERElisa Roccia
Elisa Roccia
GCGastao Cruz
Gastao Cruz
RNRadhouene Neji
Radhouene Neji
RBRene Botnar
Rene Botnar
IDIsabel Dregely
Isabel Dregely
Purpose: To achieve 3D T2w imaging of the prostate with 1‐mm isotropic resolution in less than 3 min.Methods: We devised and implemented a 3D T2‐prepared multishot balanced steady state free precession (T2prep‐bSSFP) acquisition sequence with a variable density undersampled trajectory combined with a total variation regularized iterative SENSE (TV‐SENSE) reconstruction. Prospectively undersampled images of the prostate (acceleration factor R = 3) were acquired in 11 healthy subjects in an institutional review board‐approved study. Image quality metrics (subjective signal‐to‐noise ratio, contrast, sharpness, and overall prostate image quality) were evaluated by 2 radiologists. Scores of the proposed accelerated sequence were compared using the Wilcoxon signed‐rank and Kruskal‐Wallis non‐parametric tests to prostate images acquired using a fully sampled 3D T2prep‐bSSFP acquisition, and with clinical standard 2D and 3D turbo spin echo (TSE) T2w acquisitions. A P‐value < 0.05 was considered significant.Results: The 3× accelerated 3D T2prep‐bSSFP images required a scan time (min:s) of 2:45, while the fully sampled 3D T2prep‐bSSFP and clinical standard 3D TSE images were acquired in 8:23 and 7:29, respectively. Image quality scores (contrast, sharpness, and overall prostate image quality) of the accelerated 3D T2prep‐bSSFP, fully sampled T2prep‐bSSFP, and clinical standard 3D TSE acquisitions along all 3 spatial dimensions were not significantly different (P > 0.05).Conclusion: 3D T2w images of the prostate with 1‐mm isotropic resolution can be acquired in less than 3 min, with image quality that is comparable to a clinical standard 3D TSE sequence but only takes a third of the acquisition time.