Elisa Roccia

Elisa Roccia

Auto-generated profile, based on publicly available information

Elisa Roccia

School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
ERElisa Roccia
Elisa Roccia
AMArthur Mikhno
Arthur Mikhno
ROR. Todd Ogden
R. Todd Ogden
JMJ. John Mann
J. John Mann
ALAndrew F. Laine
Andrew F. Laine
Francesca ZanderigoFrancesca Zanderigo
Francesca Zanderigo
Full quantification of regional cerebral metabolic rate of glucose (rCMRglu) with [ 18 F]fluorodeoxyglucose ([ 18 F]FDG) positron emission tomography (PET) imaging requires measurement of an arterial input function (AIF) curve, which is obtained with an invasive arterial blood sampling procedure during the scan. We previously proposed a non-invasive simultaneous estimation (nSIME) method that quantifies binding of a PET radioligand by combining individual electronic health records information and a pharmacokinetic AIF (PK-AIF) model. Initially applied only to [ 11 C]DASB data, in this study we validate nSIME for a different radioligand, [ 18 F]FDG, adapting the algorithm to the specific distribution and metabolism of this radioligand. We evaluate the impact of the PK-AIF model, the number of [ 18 F]FDG-specific soft constraints, and the type of predictive strategy. The accuracy of nSIME is then compared to a population-based approach. All analyses are conducted on 67 [ 18 F]FDG PET scans with arterial blood data available for comparison. nSIME performance is optimal for [ 18 F]FDG when using the PK-AIF model, two soft constraints, and an aggregate model to predict the soft constraint values. Higher correlation and lower Bland-Altman spread against gold standard rCMRglu values based on arterial blood measurements are observed for nSIME (r = 0.83, spread = 1.55) compared to the population-based approach (r = 0.77, spread = 2.12). nSIME provides a data-driven estimation of both amplitude and shape of the AIF curve at the individual level and potentially enables non-invasive quantification of PET data across radioligands, avoiding the need for arterial blood sampling.

28 October 2018 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
ERElisa Roccia
Elisa Roccia
RSRohini Vidya Shankar
Rohini Vidya Shankar
RNRadhouene Neji
Radhouene Neji
GCGastão Cruz
Gastão Cruz
CMCamila Munoz
Camila Munoz
IDIsabel Dregely
Isabel Dregely

21 April 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
RSRohini Vidya Shankar
Rohini Vidya Shankar
ERElisa Roccia
Elisa Roccia
GCGastao Cruz
Gastao Cruz
RNRadhouene Neji
Radhouene Neji
RBRene Botnar
Rene Botnar
IDIsabel Dregely
Isabel Dregely
Purpose: To achieve 3D T2w imaging of the prostate with 1‐mm isotropic resolution in less than 3 min.Methods: We devised and implemented a 3D T2‐prepared multishot balanced steady state free precession (T2prep‐bSSFP) acquisition sequence with a variable density undersampled trajectory combined with a total variation regularized iterative SENSE (TV‐SENSE) reconstruction. Prospectively undersampled images of the prostate (acceleration factor R = 3) were acquired in 11 healthy subjects in an institutional review board‐approved study. Image quality metrics (subjective signal‐to‐noise ratio, contrast, sharpness, and overall prostate image quality) were evaluated by 2 radiologists. Scores of the proposed accelerated sequence were compared using the Wilcoxon signed‐rank and Kruskal‐Wallis non‐parametric tests to prostate images acquired using a fully sampled 3D T2prep‐bSSFP acquisition, and with clinical standard 2D and 3D turbo spin echo (TSE) T2w acquisitions. A P‐value < 0.05 was considered significant.Results: The 3× accelerated 3D T2prep‐bSSFP images required a scan time (min:s) of 2:45, while the fully sampled 3D T2prep‐bSSFP and clinical standard 3D TSE images were acquired in 8:23 and 7:29, respectively. Image quality scores (contrast, sharpness, and overall prostate image quality) of the accelerated 3D T2prep‐bSSFP, fully sampled T2prep‐bSSFP, and clinical standard 3D TSE acquisitions along all 3 spatial dimensions were not significantly different (P > 0.05).Conclusion: 3D T2w images of the prostate with 1‐mm isotropic resolution can be acquired in less than 3 min, with image quality that is comparable to a clinical standard 3D TSE sequence but only takes a third of the acquisition time.

28 September 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
ERElisa Roccia
Elisa Roccia
RNRadhouene Neji
Radhouene Neji
TBThomas Benkert
Thomas Benkert
BKBerthold Kiefer
Berthold Kiefer
VGVicky Goh
Vicky Goh
IDIsabel Dregely
Isabel Dregely
Purpose: To achieve three‐dimensional (3D) distortion‐free apparent diffusion coefficient (ADC) maps for prostate imaging using a multishot diffusion prepared‐gradient echo (msDP‐GRE) sequence and ADC dictionary matching.Methods: The msDP‐GRE sequence is combined with a 3D Cartesian, centric k‐space trajectory with center oversampling. Oversampled k‐space center averaging and phase cycling are used to address motion‐ and eddy current–induced magnitude corruption. Extended‐phase‐graph (EPG) simulations and ADC dictionary matching are used to compensate for T1 effects. To shorten the acquisition time, each volume is undersampled by a factor of two and reconstructed using iterative sensitivity encoding. The proposed approach is characterized using simulations and validated in a kiwifruit phantom, comparing the msDP‐GRE ADC maps obtained using both standard monoexponential fitting and dictionary matching with the clinical standard single‐shot diffusion weighted‐echo planar imaging (ssDW‐EPI) ADC. Initial in vivo feasibility is tested in three healthy subjects, and geometric distortion is compared with anatomical T2‐weighted‐turbo spin echo.Results: In the kiwifruit phantom experiment, the signal magnitude could be recovered using k‐space center averaging and phase cycling. No statistically significant difference was observed in the ADC values estimated using msDP‐GRE with dictionary matching and clinical standard DW‐EPI (P < .05). The in vivo prostate msDP‐GRE scans were free of geometric distortion caused by off‐resonance susceptibility, and the ADC values in the prostate were in agreement with values found in the published literature.Conclusion: Nondistorted 3D ADC maps of the prostate can be achieved using a msDP sequence and dictionary matching.