Adam Loveday

Adam Loveday

Auto-generated profile, based on publicly available information

Adam Loveday

School of Sport, Exercise, and Health Sciences, Loughborough University, Loughborough, United Kingdom

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 May 2016 in Journal of Medical Internet Research
Verified
Journal Article
Open access
James  Sanders James Sanders
James Sanders
ALAdam Loveday
Adam Loveday
NPNatalie Pearson
Natalie Pearson
CECharlotte Edwardson
Charlotte Edwardson
TYThomas Yates
Thomas Yates
DEDale Esliger
Dale Esliger
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet

5 August 2015 in Journal of Medical Internet Research
Verified
Journal Article
Open access
ALAdam Loveday
Adam Loveday
Lauren SherarLauren Sherar
Lauren Sherar
James  Sanders James Sanders
James Sanders
PSPaul W Sanderson
Paul W Sanderson
DEDale Esliger
Dale Esliger
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet

21 September 2016 in Physiological Measurement
Verified
Journal Article
Open access
PDF file
ALAdam Loveday
Adam Loveday
Lauren SherarLauren Sherar
Lauren Sherar
James  Sanders James Sanders
James Sanders
PSPaul W Sanderson
Paul W Sanderson
DEDale Esliger
Dale Esliger
When used in large, national surveillance programmes, objective measurement tools provide prevalence estimates of low physical activity guideline compliance and high amounts of sedentary time. There are undoubtedly a plethora of reasons for this but one possible contributing factor is the current lack of behavioural context offered by accelerometers and posture sensors. Context includes information such as where the behaviour occurs, the type of activity being performed and is vital in allowing greater refinement of intervention strategies. Novel technologies are emerging with the potential to provide this information. Example data from three ongoing studies is used to illustrate the utility of these technologies. Study one assesses the concurrent validity of electrical energy monitoring and wearable cameras as measures of television viewing. This study found that on average the television is switched on for 202 min d −1 but is visible in just 90 min of wearable camera images with a further 52 min where the participant is in their living room but the television is not visible in the image. Study two utilises indoor location monitoring to assess where older adult care home residents accumulate their sedentary time. This study found that residents were highly sedentary (sitting for an average of 720 min d −1 ) and spent the majority of their time in their own rooms with more time spent in communal areas in the morning than in the afternoon. Lastly, study three discusses the use of proximity sensors to quantify exposure to a height adjustable desk. These studies are example applications of this technology, with many other technologies available and applications possible. The adoption of these technologies will provide researchers with a more complete understanding of the behaviour than has previously been available.

20 April 2018 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
DMDaniele Magistro
Daniele Magistro
SSSalvatore Sessa
Salvatore Sessa
AKAndrew Kingsnorth
Andrew Kingsnorth
ALAdam Loveday
Adam Loveday
Alessandro SimeoneAlessandro Simeone
Alessandro Simeone
DEDale Esliger
Dale Esliger
Mobile and tablet apps, ubiquitous and pervasive computing, wearable computing and domotics for health.

24 July 2017 in JMIR Preprints
Verified
Preprint
Open access
DMDaniele Magistro
Daniele Magistro
SSSalvatore Sessa
Salvatore Sessa
AKAndrew Kingsnorth
Andrew Kingsnorth
ALAdam Loveday
Adam Loveday
Alessandro SimeoneAlessandro Simeone
Alessandro Simeone
DEDale Esliger
Dale Esliger
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Unfortunately, global efforts to promote “how much” physical activity people should be undertaking have been largely unsuccessful. Given the difficulty of achieving a sustained lifestyle behavior change, many scientists are reexamining their approaches. One such approach is to focus on understanding the context of the lifestyle behavior (ie, where, when, and with whom) with a view to identifying promising intervention targets. Objective: The aim of this study was to develop and implement an innovative algorithm to determine “where” physical activity occurs using proximity sensors coupled with a widely used physical activity monitor. Methods: A total of 19 Bluetooth beacons were placed in fixed locations within a multilevel, mixed-use building. In addition, 4 receiver-mode sensors were fitted to the wrists of a roving technician who moved throughout the building. The experiment was divided into 4 trials with different walking speeds and dwelling times. The data were analyzed using an original and innovative algorithm based on graph generation and Bayesian filters. Results: Linear regression models revealed significant correlations between beacon-derived location and ground-truth tracking time, with intraclass correlations suggesting a high goodness of fit (R2=.9780). The algorithm reliably predicted indoor location, and the robustness of the algorithm improved with a longer dwelling time (>100 s; error <10%, R2=.9775). Increased error was observed for transitions between areas due to the device sampling rate, currently limited to 0.1 Hz by the manufacturer. Conclusions: This study shows that our algorithm can accurately predict the location of an individual within an indoor environment. This novel implementation of “context sensing” will facilitate a wealth of new research questions on promoting healthy behavior change, the optimization of patient care, and efficient health care planning (eg, patient-clinician flow, patient-clinician interaction).