Fumi Nakano

Fumi Nakano

Auto-generated profile, based on publicly available information

Fumi Nakano

Kanagawa Prefectural Institute of Public Health

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2023 in Journal of Chromatography A
Verified
Journal Article
Closed access
INIwaki Nishi
Iwaki Nishi
TYTaichi Yoshitomi
Taichi Yoshitomi
FNFumi Nakano
Fumi Nakano
HUHitoshi Uemura
Hitoshi Uemura
MTMaiko Tahara
Maiko Tahara
TKTsuyoshi Kawakami
Tsuyoshi Kawakami

23 February 2025 in Chemosphere
Verified
Journal Article
Closed access
INIwaki Nishi
Iwaki Nishi
TYTaichi Yoshitomi
Taichi Yoshitomi
FNFumi Nakano
Fumi Nakano
HUHitoshi Uemura
Hitoshi Uemura
TKTsuyoshi Kawakami
Tsuyoshi Kawakami

1 January 2023 in Journal of Environmental Chemistry
Verified
Journal Article
Open access
PDF file
NKNorihiro Kobayashi
Norihiro Kobayashi
YTYuko Tsuchiya
Yuko Tsuchiya
STSokichi Takagi
Sokichi Takagi
JYJin Yoshida
Jin Yoshida
KOKaori Ookubo
Kaori Ookubo
YIYoshiaki Ikarashi
Yoshiaki Ikarashi
In order to adopt "screening analysis" in drinking water quality testing, which performs qualitative and quantitative analysis based on information registered in a database without measuring standard materials at the time of each testing, a validation test was conducted to evaluate the difference on the chromatogram data analysis by analysts. In the validation test, chromatograms of 6 water samples were analyzed using the same database and software by 16 analysts in 13 laboratories. Peak identification was performed based on Retention time (RT), (qualifier and target ion) QT ratio, and degree of matching of mass spectra, and if necessary, peak shapes in water samples were compared with those in calibration curve samples. Large differences were observed in the detection of pesticides among the analysts. There were two main reasons for the disagreement. The first is that the judgement of peak detection at low concentrations near the quantification limit of each pesticide, particularly below the concentration at three times of quantification limit, differed depending on the analyst. The other reason was that some analysts made clear misidentifications and identified wrong peaks close to the predicted retention time, despite the QT ratio and mass spectrum didn't match that in the database. In addition, there were some cases where the quantified values were reported by misidentifying the peaks of degradation products and metabolites, even when the peak detection was correctly judged. In order to use screening analysis practically by drinking water quality testing laboratories, it is important to conduct a validation test like this study in advance to use screening analysis and to coordinate criteria for peak identification and quantification among data analysts.

1 January 2022 in Journal of Japan Society on Water Environment
Verified
Journal Article
Open access
PDF file
NKNorihiro Kobayashi
Norihiro Kobayashi
STSokichi Takagi
Sokichi Takagi
TKTeruaki Kinoshita
Teruaki Kinoshita
FNFumi Nakano
Fumi Nakano
KFKoji Furukawa
Koji Furukawa
YIYoshiaki Ikarashi
Yoshiaki Ikarashi
水道水質基準や目標値が設定されている6種類の陰イオンを一斉分析可能なLC/MSあるいはLC/MS/MS分析条件を検討した。さらに, 本研究で確立した分析条件が, 様々な種類の水道水や機種に適用できるかどうか検証するために, 15機関で分析法のバリデーション試験を実施した。水道水を用いた添加回収試験の結果, 臭素酸, 塩素酸, 亜塩素酸, 過塩素酸の4物質は, それぞれ12機関以上が良好な分析精度が得られたことから, 本分析法は水道水に含まれるこれら4種類の陰イオンを高精度に一斉分析可能と考えられる。ただし, チオ硫酸ナトリウムによる亜塩素酸の分解が見られたことから, 亜塩素酸を分析する場合にはEDAで脱塩素処理を行う必要がある。また, 物質によって検量線の直線性が確保できる範囲が大きく異なったことから, これらの陰イオンの分析においては検量線の妥当性が確保できる範囲を確認した上で適切な検量線を作成する必要がある。