Marti Boss

Marti Boss

Auto-generated profile, based on publicly available information

Marti Boss

Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2019 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
MBMarti Boss
Marti Boss
MBMijke Buitinga
Mijke Buitinga
TJTom J.P. Jansen
Tom J.P. Jansen
MBMaarten Brom
Maarten Brom
EVEric P. Visser
Eric P. Visser
MGMartin Gotthardt
Martin Gotthardt
68Ga-NODAGA-exendin-4 is a promising tracer for β-cell imaging using PET/CT. Possible applications include preoperative visualization of insulinomas and discrimination between focal and diffuse forms of congenital hyperinsulinism. There is also a significant role for this tracer in extending our knowledge on the role of β-cell mass in the pathophysiology of type 1 and type 2 diabetes by enabling noninvasive quantification of tracer uptake as a measure for β-cell mass. Calculating radiation doses from this tracer is important to assess its safety for use in patients (including young children) with benign diseases and healthy individuals. Methods: Six patients with hyperinsulinemic hypoglycemia were included. After intravenous injection of 100 MBq of the tracer, 4 successive PET/CT scans were obtained at 30, 60, 120, and 240 min after injection. Tracer activity in the pancreas, kidneys, duodenum, and remainder of the body were determined, and time-integrated activity coefficients for the measured organs were calculated. OLINDA/EXM software, version 1.1, was applied to calculate radiation doses using the reference adult male and female models and to estimate radiation doses to children. Results: The mean total effective dose for adults was very low (0.71 ± 0.07 mSv for a standard injected dose of 100 MBq). The organ with the highest absorbed dose was the kidney (47.3 ± 10.2 mGy/100 MBq). The estimated effective dose was 2.32 ± 0.32 mSv for an injected dose of 20 MBq in newborns. This dose decreased to 0.77 ± 0.11 mSv/20 MBq for 1-y-old children and 0.59 ± 0.05 mSv for an injected dose of 30 MBq in 5-y-old children. Conclusion: Our human PET/CT-based dosimetric calculations show that the effective radiation doses from the novel tracer 68Ga-NODAGA-exendin-4 are very low for adults and children. The doses are lower than reported for other polypeptide tracers such as somatostatin analogs (2.1–2.6 mSv/100 MBq) and are beneficial for application as a research tool, especially when repeated examinations are needed.

2 July 2021 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
MBMarti Boss
Marti Boss
CRChristof Rottenburger
Christof Rottenburger
WBWinfried Brenner
Winfried Brenner
OBOliver Blankenstein
Oliver Blankenstein
VPVikas Prasad
Vikas Prasad
MGMartin Gotthardt
Martin Gotthardt
Surgery with curative intent can be offered to congenital hyperinsulinism (CHI) patients, provided that the lesion is focal. Radiolabeled exendin-4 specifically binds the glucagonlike peptide 1 receptor on pancreatic β-cells. In this study, we compared the performance of 18F-DOPA PET/CT, the current standard imaging method for CHI, and PET/CT with the new tracer 68Ga-NODAGA-exendin-4 in the preoperative detection of focal CHI. Methods: Nineteen CHI patients underwent both 18F-DOPA PET/CT and 68Ga-NODAGA-exendin-4 PET/CT before surgery. The images were evaluated in 3 settings: a standard clinical reading, a masked expert reading, and a joint reading. The target (lesion)-to-nontarget (normal pancreas) ratio was determined using SUVmax. Image quality was rated by pediatric surgeons in a questionnaire. Results: Fourteen of 19 patients having focal lesions underwent surgery. On the basis of clinical readings, the sensitivity of 68Ga-NODAGA-exendin-4 PET/CT (100%; 95% CI, 77%–100%) was higher than that of 18F-DOPA PET/CT (71%; 95% CI, 42%–92%). Interobserver agreement between readings was higher for 68Ga-NODAGA-exendin-4 than for 18F-DOPA PET/CT (Fleiss κ = 0.91 vs. 0.56). 68Ga-NODAGA-exendin-4 PET/CT provided significantly (P = 0.021) higher target-to-nontarget ratios (2.02 ± 0.65) than did 18F-DOPA PET/CT (1.40 ± 0.40). On a 5-point scale, pediatric surgeons rated 68Ga-NODAGA-exendin-4 PET/CT as superior to 18F-DOPA PET/CT. Conclusion: For the detection of focal CHI, 68Ga-NODAGA-exendin-4 PET/CT has higher clinical sensitivity and better interobserver correlation than 18F-DOPA PET/CT. Better contrast and image quality make 68Ga-NODAGA-exendin-4 PET/CT superior to 18F-DOPA PET/CT in surgeons’ intraoperative quest for lesion localization. Visual Abstract

15 December 2021 in Brain Sciences
Verified
Journal Article
Open access
PDF file
LDLaura Deden
Laura Deden
JBJan Booij
Jan Booij
JGJoanes Grandjean
Joanes Grandjean
Judith HombergJudith Homberg
Judith Homberg
EHEric Hazebroek
Eric Hazebroek
MBMarti Boss
Marti Boss
Stimulation of glucagon-like peptide-1 (GLP-1) receptors increases the insulin release in the pancreas during high glucose levels, and also stimulates a feeling of satiety. Likewise, synthetic GLP-1 receptor agonists derived from exendin are used successfully in the treatment of type-2 diabetes mellitus and obesity. Interestingly, preclinical and clinical studies further suggest that GLP-1 receptor agonists may decrease motor, behavioral, and cognitive symptoms in (animal models) Parkinson’s disease and Alzheimer’s disease and may slow down neurodegeneration. These observations suggest stimulation of GLP-1 receptors in the brain. The GLP-1 positron emission tomography (PET) tracer 68Ga-NODAGA-exendin-4 has been developed and successfully used for imaging in humans. In an ongoing study on the effects of bariatric surgery on GLP-1 receptor expression, we performed 68Ga-NODAGA-exendin-4 PET in obese subjects. Here we evaluated whether GLP-1 receptor binding could be visualized in the central nervous system in 10 obese subjects (seven woman; body mass index: mean ± SD: 39 ± 4.4 kg/m2) before bariatric surgery. Although we observed clear uptake in the pituitary area (mean SUVmax 4.3 ± 2.3), we found no significant uptake in other parts of the brain. We conclude that 68Ga-NODAGA-exendin-4 PET cannot be used to analyze GLP-1 receptors in the brain of obese subjects.

17 November 2022 in Diabetologia
Verified
Journal Article
Open access
PDF file
TJTheodorus J. P. Jansen
Theodorus J. P. Jansen
MBMaarten Brom
Maarten Brom
MBMarti Boss
Marti Boss
MBMijke Buitinga
Mijke Buitinga
CTCees J. Tack
Cees J. Tack
Martin GotthardtMartin Gotthardt
Martin Gotthardt
Aims/hypothesis: The role of beta cell mass in the balance of glucose control and hypoglycaemic burden in people with type 1 diabetes is unclear. We applied positron emission tomography (PET) imaging with radiolabelled exendin to compare beta cell mass among people with type 1 diabetes and either low glucose variability (LGV) or high glucose variability (HGV). Methods: All participants with either LGV (n=9) or HGV (n=7) underwent a mixed-meal tolerance test to determine beta cell function and wore a blinded continuous glucose monitor for a week. After an i.v. injection with [68Ga]Ga-NODAGA-exendin-4, PET images were acquired for the quantification of pancreatic uptake of radiolabelled exendin. The mean standardised uptake value (SUVmean) of the pancreas was used to determine the amount of beta cell mass. Results: Participants with LGV had lower HbA1c (46.0 mmol/mol [44.5–52.5] [6.4% (6.3–7)] vs 80 mmol/mol [69.0–110] [9.5% (8.5–12.2)], p=0.001) and higher time in range (TIR) (75.6% [73.5–90.3] vs 38.7% [25.1–48.5], p=0.002) than those with HGV. The SUVmean of the pancreas was higher for the LGV than for the HGV group (5.1 [3.6–5.6] vs 2.9 [2.1–3.4], p=0.008). The AUCC-peptide:AUCglucose ratio was numerically, but not statistically, higher in the LGV compared with the HGV group (2.7×10−2 [6.2×10−4–5.3×10−2] vs 9.3×10−4 [4.7×10−4–5.2×10−3], p=0.21). SUVmean correlated with the AUCC-peptide:AUCglucose ratio (Pearson r=0.64, p=0.01), as well as with the TIR (r=0.64, p=0.01) and the SD of interstitial glucose levels (r=−0.66, p=0.007). Conclusion/interpretation: Our data show higher beta cell mass in people with type 1 diabetes and LGV than in those with HGV, independent of beta cell function. Graphical

17 April 2023 in Diabetes
Verified
Journal Article
Closed access
PDF file
TJTheodorus J.P. Jansen
Theodorus J.P. Jansen
MBMijke Buitinga
Mijke Buitinga
MBMarti Boss
Marti Boss
MNMichiel F. Nijhoff
Michiel F. Nijhoff
MBMaarten Brom
Maarten Brom
MGMartin Gotthardt
Martin Gotthardt
Intrahepatic transplantation of islets of Langerhans (ITx) is a treatment option for individuals with complicated type 1 diabetes and profoundly unstable glycemic control, but its therapeutic success is hampered by deterioration of graft function over time. To improve ITx strategies, technologies to noninvasively monitor the fate and survival of transplanted islets over time are of great potential value. We used [68Ga]Ga-NODAGA-exendin-4 (68Ga-exendin) positron emission tomography (PET)/computed tomography (CT) imaging to demonstrate the feasibility of quantifying β-cell mass in intrahepatic islet grafts in 13 individuals with type 1 diabetes, nine after ITx with functional islet grafts and four control patients not treated with ITx. β-Cell function was measured by mixed-meal tolerance test. With dynamic 68Ga-exendin PET/CT images, we determined tracer accumulation in hepatic hotspots, and intrahepatic fat was assessed using MRI and spectroscopy. Quantification of hepatic hotspots showed a significantly higher uptake of 68Ga-exendin in the ITx group compared with the control group (median 0.55 [interquartile range 0.51–0.63] vs. 0.43 [0.42–0.45]). GLP-1 receptor expression was found in transplanted islets by immunohistochemistry. Intrahepatic fat was not detected in a majority of the individuals. Our study provides the first clinical evidence that radiolabeled exendin imaging can be used to monitor viable transplanted islets after intraportal ITx. Article Highlights: This clinical study researched the potential of radiolabeled exendin to follow the fate and survival of intrahepatic islet grafts. Is it feasible to quantitatively detect intrahepatic islet transplants with [68Ga]Ga-NODAGA-exendin-4 (68Ga-exendin) positron emission tomography (PET) imaging? Our study findings indicate that the imaging technique 68Ga-exendin PET can be used to monitor viable islet mass after intrahepatic islet transplantation in humans. Alongside functional measures, 68Ga-exendin PET imaging could significantly aid in the evaluation of strategies designed to improve islet engraftment, survival, and function.

15 January 2022 in Molecules
Verified
Journal Article
Open access
PDF file
SMSilvia Migliari
Silvia Migliari
ASAntonino Sammartano
Antonino Sammartano
MBMarti Boss
Marti Boss
Martin GotthardtMartin Gotthardt
Martin Gotthardt
MSMaura Scarlattei
Maura Scarlattei
Livia RuffiniLivia Ruffini
Livia Ruffini
Background: Glucagon-like peptide 1 receptor (GLP-1R) is preferentially expressed in pancreatic islets, especially in β-cells, and highly expressed in human insulinomas and gastrinomas. In recent years several GLP-1R–avid radioligands have been developed to image insulin-secreting tumors or to provide a tentative quantitative in vivo biomarker of pancreatic β-cell mass. Exendin-4, a 39-amino acid peptide with high binding affinity to GLP-1R, has been labeled with Ga-68 for imaging with positron emission tomography (PET). Preparation conditions may influence the quality and in vivo behavior of tracers. Starting from a published synthesis and quality controls (QCs) procedure, we have developed and validated a new rapid and simple UV-Radio-HPLC method to test the chemical and radiochemical purity of [68Ga]Ga-NODAGA-exendin-4, to be used in the clinical routine. Methods: Ga-68 was obtained from a 68Ge/68Ga Generator (GalliaPharma®) and purified using a cationic-exchange cartridge on an automated synthesis module (Scintomics GRP®). NODAGA-exendin-4 contained in the reactor (10 µg) was reconstituted with HEPES and ascorbic acid. The reaction mixture was incubated at 100 °C. The product was purified through HLB cartridge, diluted, and sterilized. To validate the proposed UV-Radio-HPLC method, a stepwise approach was used, as defined in the guidance document released by the International Conference on Harmonization of Technical Requirements of Pharmaceuticals for Human Use (ICH), adopted by the European Medicines Agency (CMP/ICH/381/95 2014). The assessed parameters are specificity, linearity, precision (repeatability), accuracy, and limit of quantification. Therefore, a range of concentrations of Ga-NODAGA-exendin-4, NODAGA-exendin-4 (5, 4, 3.125, 1.25, 1, and 0.75 μg/mL) and [68Ga]Ga-NODAGA-exendin-4 were analyzed. To validate the entire production process, three consecutive batches of [68Ga]Ga-NODAGA-exendin-4 were tested. Results: Excellent linearity was found between 5–0.75 μg/mL for both the analytes (NODAGA-exendin-4 and 68Ga-NODAGA-exendin-4), with a correlation coefficient (R2) for calibration curves equal to 0.999, average coefficients of variation (CV%) < 2% (0.45% and 0.39%) and average per cent deviation value of bias from 100%, of 0.06% and 0.04%, respectively. The calibration curve for the determination of [68Ga]Ga-NODAGA-exendin-4 was linear with a R2 of 0.993 and CV% < 2% (1.97%), in accordance to acceptance criteria. The intra-day and inter-day precision of our method was statistically confirmed using 10 μg of peptide. The mean radiochemical yield was 45 ± 2.4% in all the three validation batches of [68Ga]Ga-NODAGA-exendin-4. The radiochemical purity of [68Ga]Ga-NODAGA-exendin-4 was >95% (97.05%, 95.75% and 96.15%) in all the three batches. Conclusions: The developed UV-Radio-HPLC method to assess the radiochemical and chemical purity of [68Ga]Ga-NODAGA-exendin-4 is rapid, accurate and reproducible like its fully automated production. It allows the routine use of this PET tracer as a diagnostic tool for PET imaging of GLP-1R expression in vivo, ensuring patient safety.