Tiantian Zou

Tiantian Zou

Auto-generated profile, based on publicly available information

Tiantian Zou

State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing 400044, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2019 in IEEE Access
Verified
Journal Article
Open access
LYLijun Yang
Lijun Yang
TZTiantian Zou
Tiantian Zou
BDBangfei Deng
Bangfei Deng
HZHaibing Zhang
Haibing Zhang
YMYang Mo
Yang Mo
PPPan Peng
Pan Peng
Moisture content and aging of oil-paper insulation are two important factors that cause deterioration of the insulation performance of power transformers. The water molecules and aging products are polar, which affects the dielectric response characteristics of the insulation system. Therefore, diagnosing the moisture content and aging status of oil-paper insulation using the dielectric response testing technology has become a hot topic of research. Current technology has realized non-destructive evaluation of the moisture content of transformer insulation. However, changes in the dielectric response caused by aging products is easily concealed by the influence of moisture, which makes the diagnostic technology ineffective for use in the evaluation of the aging of the oil-paper system, which will affect the water balance between the oil and the paper. Experimental studies have shown that the water distribution coefficient between oil and paper and the degree of polymerization of the insulating paper shows a significant linear relationship. A new method utilizing frequency domain dielectric spectroscopy (FDS) and the water balance characteristics of oil-paper insulation is proposed in this paper to evaluate the aging state of oil-paper insulation. This method uses FDS curves to evaluate the moisture content of the insulating paper, uses oil samples to measure the moisture content of the oil, and uses the ratio between the moisture contents of the oil and paper as the aging characteristic parameter to evaluate the aging status of oil-paper insulation. The feasibility of the proposed method is preliminarily verified using oil-paper insulation samples at different aging states and with different moisture levels in the laboratory

25 July 2019 in IEEE Access
Verified
Journal Article
Open access
MYMo Yang
Mo Yang
LYLijun Yang
Lijun Yang
TZTiantian Zou
Tiantian Zou
WHWei Hou
Wei Hou
RLRuijin Liao
Ruijin Liao
Kevlar pulp treated with low temperature plasma and Nano cellulose fibrils (NCF) have been introduced as reinforcements in the preparation for composite insulating paper with low relative permittivity, dielectric loss, good mechanical properties, and thermal stability. More polar groups of Kevlar fibers could be exposed after plasma treatment. Results showed that the relative permittivity of the composite paper containing 20% Kevlar pulp, 10% NCF and 70% softwood pulp decreased by 29.6% and the dielectric loss decreased by 43.2% at 50 Hz, 25 °C, compared with the conventional paper formed by pure softwood pulp. The change was due to the introduction of Kevlar pulp with intrinsic low dielectric constant and loss, which decreases the whole polarizability of the paper. The mechanical properties of the composite paper became worse after introducing 20% Kevlar pulp. 10% NCF can work as a mechanical reinforcement to compensate for the tensile and Yang’s modulus loss. Scanning electron microscopy results showed that NCF could fill the void defects and improve the interface bonding of the fibers to enhance the paper mechanical properties. The composite paper also had better insulating and thermal properties than the conventional paper. It has been concluded that Kevlar pulp/NCF/softwood pulp composite paper has the potential to replace pure softwood paper for the application of high voltage AC transformer insulation.