M.G. Matt Syal

M.G. Matt Syal

Auto-generated profile, based on publicly available information

M.G. Matt Syal

School of Planning, Design, and Construction, Michigan State University,East Lansing, Michigan, USA

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2013 in Journal of Management in Engineering
Verified
Journal Article
Closed access
JJJae G. Jeong
Jae G. Jeong
Makarand HastakMakarand Hastak
Makarand Hastak
MSMatt Syal
Matt Syal
Taehoon HongTaehoon Hong
Taehoon Hong

29 March 2022 in Open House International
Verified
Journal Article
Closed access
JSJuntae Jake Son
Juntae Jake Son
SKSuk-Kyung Kim
Suk-Kyung Kim
MSM.G. Matt Syal
M.G. Matt Syal
Purpose: The purpose of this study is to examine the energy savings in the indoor environment, using strategies that adopt the characteristics of nature, called biomimetic solutions. This research designed a biomimetic window system to bring daylight into interior spaces in educational buildings where daylight cannot be reached. Specifically, this study assessed how the daylight that was achieved via a biomimetic window system would affect energy savings using an energy simulation method.Design/methodology/approach: This study explored how biomimetic methods would affect the building environment and which biomimetic method would involve the building's energy saving with daylight. The research intended to develop a novel biomimetic window system that can bring daylight to the basement floor of an existing building on a university campus to find out how much the biomimetic window system would affect the energy savings of the building. Referring to the existing building's layout and structure, energy simulation models were developed, and the energy consumptions were estimated.Findings: Simulation models proved that the biomimetic window system has sufficient performance to bring more daylight to the basement floor of the building. Furthermore, it was confirmed that the use of the biomimetic window system for the building could reduce energy usage compared to the actual energy usage of the current building without biomimetic windows.Research limitations/implications: First, this study was adopted as a computer-designed simulation method instead of using a real-world system. Although this study designed the biomimetic window system based on previous studies, it should be considered the possibility of other problems when the system is actually built in. Second, it is necessary to predict how much an initial budget is required when the system is built. It means that this study did not calculate the lifecycle cost of the biomimetic window system. It will also be necessary to compare energy consumption to the required initial budget. Lastly, this study was simulated based on weather data in cold regions, and it did not compare/analyze different climate regions. Different results may be predicted if the biomimetic window system is built in different climatic regions.Originality/value: This research showed new practical ways to capture and transmit solar heat and light using a biomimetic solution. Furthermore, using the proposed novel biomimetic window system, the amount of energy reduction can be calculated, and this method could be applied in the interior non-window spaces of academic and related types of buildings.