1 May 2021 in China Communications
With the successful demonstration of terahertz (THz) high-speed wireless data transmission, the THz frequencies are now becoming a worth candidate for post-5G wireless communications. On the other hand, to bring THz communications a step closer to real scenario application, solving high data rate realtime transmission is also an important issue. This paper describes a 220-GHz solid-state dual-carrier wireless link whose maximum transmission real-time data rates are 20.8 Gbps (10.4 Gbps per channel). By aggregating two carrier signals in the THz band, the contradiction between high real-time data rate communication and low sampling rate analog-to-digital (ADC) and digital-to-analog converter (DAC) is alleviated. The transmitting and receiving front-ends consist of 220-GHz diplexers, 220-GHz sub-harmonic mixers based on anti-parallel Schottky barrier diodes, G-band low-noise amplifiers (LNA), WR-4.3 band high-gain Cassegrain antennas, high data rates dual-DAC and —ADC baseband platform and other components. The low-density parity-check (LDPC) encoding is also realized to improve the bit error rate (BER) of the received signal. Modulated signals are centered at 214.4 GHz and 220.6 GHz with −11.9 dBm and −13.4 dBm output power for channel 1 and 2, respectively. This link is demonstrated to achieve 20.8-Gbps real-time data transmission using 16-QAM modulation over a distance of 1030 m. The measured signal to noise ratio (SNR) is 17.3 dB and 16.5 dB, the corresponding BER is 8.6e-7 and 3.8e-7, respectively. Furthermore, 4K video transmission is also carried out which is clear and free of stutter. The successful transmission of aggregated channels in this wireless link shows the great potential of THz communication for future wireless high-rate real-time data transmission applications.
1 January 2020 in Nuclear Technology and Radiation Protection
A condenser control system of a nuclear power plant consists of a pressure control system, a condensate water sub-cooling degree control system and a water level control system. The existing control optimization methods can hardly take into account all the performance indices of the three control systems at the same time. To solve this problem, this paper presents a control optimization method based on a multi-objective optimization algorithm. This method takes control parameters as optimization objects, and takes the performance of step response as optimization objectives. The multi-objective particle swarm optimization algorithm based on Pareto dominance concept is used to solve the optimization problem. This enables obtaining of high-quality control parameters. Simulation results confirm the feasibility and effectiveness of this control optimization method.
9 October 2024 in JMIR Medical Informatics
Background: The increasing demand for personal health record (PHR) systems is driven by individuals’ desire to actively manage their health care. However, the limited functionality of current PHR systems has affected users’ willingness to adopt them, leading to lower-than-expected usage rates. The HL7 (Health Level Seven) PHR System Functional Model (PHR-S FM) was proposed to address this issue, outlining all possible functionalities in PHR systems. Although the PHR-S FM provides a comprehensive theoretical framework, its practical effectiveness and applicability have not been fully explored. Objective: This study aimed to design and develop a tethered PHR prototype in accordance with the guidelines of the PHR-S FM. It sought to explore the feasibility of applying the PHR-S FM in PHR systems by comparing the prototype with the results of previous research. Methods: The PHR-S FM profile was defined to meet broad clinical data management requirements based on previous research. We designed and developed a PHR prototype as a web application using the Fast Healthcare Interoperability Resources R4 (FHIR) and Logical Observation Identifiers Names and Codes (LOINC) coding system for interoperability and data consistency. We validated the prototype using the Synthea dataset, which provided realistic synthetic medical records. In addition, we compared the results produced by the prototype with those of previous studies to evaluate the feasibility and implementation of the PHR-S FM framework. Results: The PHR prototype was developed based on the PHR-S FM profile. We verified its functionality by demonstrating its ability to synchronize data with the FHIR server, effectively managing and displaying various health data types. Validation using the Synthea dataset confirmed the prototype’s accuracy, achieving 100% coverage across 1157 data items. A comparison with the findings of previous studies indicated the feasibility of implementing the PHR-S FM and highlighted areas for future research and improvements. Conclusions: The results of this study offer valuable insights into the potential for practical application and broad adoption of the PHR-S FM in real-world health care settings.