K. M. Shihab Uddin

K. M. Shihab Uddin

Auto-generated profile, based on publicly available information

K. M. Shihab Uddin

Washington Univ. in St. Louis (United States)

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2018 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
HVHamed Vavadi
Hamed Vavadi
AMAtahar Mostafa
Atahar Mostafa
FZFeifei Zhou
Feifei Zhou
KUK. M. Shihab Uddin
K. M. Shihab Uddin
MAMurad Althobaiti
Murad Althobaiti
QZQuing Zhu Zhu
Quing Zhu Zhu
Near-infrared diffuse optical tomography (DOT) has demonstrated a great potential as an adjunct modality for differentiation of malignant and benign breast lesions and for monitoring treatment response in patients with locally advanced breast cancers. The path toward commercialization of DOT techniques depends upon the improvement of robustness and user-friendliness of this technique in hardware and software. In this study, we introduce our recently developed ultrasound-guided DOT system, which has been improved in system compactness, robustness, and user-friendliness by custom-designed electronics, automated data preprocessing, and implementation of a new two-step reconstruction algorithm. The system performance has been tested with several sets of solid and blood phantoms and the results show accuracy in reconstructed absorption coefficients as well as blood oxygen saturation. A clinical example of a breast cancer patient, who was undergoing neoadjuvant chemotherapy, is given to demonstrate the system performance.

23 March 2021 in Radiology
Verified
Journal Article
Closed access
XLXiandong Leng
Xiandong Leng
KUK. M. Shihab Uddin
K. M. Shihab Uddin
WCWilliam Chapman
William Chapman
HLHongbo Luo
Hongbo Luo
SKSitai Kou
Sitai Kou
QZQuing Zhu Zhu
Quing Zhu Zhu
Coregistered endorectal photoacoustic microscopy and US imaging quantified by a neural network demonstrated excellent differentiation between rectal tumor beds with residual cancers and those witho... Background Conventional radiologic modalities perform poorly in the radiated rectum and are often unable to differentiate residual cancer from treatment scarring. Purpose To report the development ...

8 November 2017 in Biomedical Optics Express
Verified
Journal Article
Closed access
PDF file
KUK. M. Shihab Uddin
K. M. Shihab Uddin
AMAtahar Mostafa
Atahar Mostafa
MAMark Anastasio
Mark Anastasio
QZQuing Zhu Zhu
Quing Zhu Zhu
Due to the correlated nature of diffused light, the problem of reconstructing optical properties using diffuse optical tomography (DOT) is ill-posed. US-, MRI- or x-ray-guided DOT approaches can reduce the total number of parameters to be estimated and improve optical reconstruction accuracy. However, when the target volume is large, the number of parameters to estimate can exceed the number of measurements, resulting in an underdetermined imaging model. In such cases, accurate image reconstruction is difficult and regularization methods should be employed to obtain a useful solution. In this manuscript, a simple two-step reconstruction method that can produce useful image estimates in DOT is proposed and investigated. In the first step, a truncated Moore-Penrose Pseudoinverse solution is computed to obtain a preliminary estimate of the image that can be reliably determined from the measured data; subsequently, this preliminary estimate is incorporated into the design of a penalized least squares estimator that is employed to compute the final image estimate. By use of phantom data, the proposed method was demonstrated to yield more accurate images than those produced by conventional reconstruction methods. The method was also evaluated with clinical data that included 10 benign and 10 malignant cases. The capability of reconstructing high contrast malignant lesions was demonstrated to be improved by use of the proposed method.

24 April 2020 in Biomedical Optics Express
Verified
Journal Article
Closed access
KUK. M. Shihab Uddin
K. M. Shihab Uddin
MZMenghao Zhang
Menghao Zhang
MAMark Anastasio
Mark Anastasio
QZQuing Zhu Zhu
Quing Zhu Zhu
Ultrasound (US)-guided near-infrared diffuse optical tomography (DOT) has demonstrated great potential as an adjunct breast cancer diagnosis tool to US imaging alone, especially in reducing unnecessary benign biopsies. However, DOT data processing and image reconstruction speeds remain slow compared to the real-time speed of US. Real-time or near real-time diagnosis with DOT is an important step toward the clinical translation of US-guided DOT. Here, to address this important need, we present a two-stage diagnostic strategy that is both computationally efficient and accurate. In the first stage, benign lesions are identified in near real-time by use of a random forest classifier acting on the DOT measurements and the radiologists’ US diagnostic scores. Any lesions that cannot be reliably classified by the random forest classifier will be passed on to the second stage which begins with image reconstruction. Functional information from the reconstructed hemoglobin concentrations is employed by a Support Vector Machine (SVM) classifier for diagnosis at the end of the second stage. This two-step classification approach which combines both perturbation data and functional features, results in improved classification, as denoted by the receiver operating characteristic (ROC) curve. Using this two-step approach, the area under the ROC curve (AUC) is 0.937 ± 0.009, with a sensitivity of 91.4% and specificity of 85.7%. In comparison, using functional features and US score yields an AUC of 0.892 ± 0.027, with a sensitivity of 90.2% and specificity of 74.5%. Most notably, the specificity is increased by more than 10% due to the implementation of the random forest classifier.

22 May 2019 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
KUK. M. Shihab Uddin
K. M. Shihab Uddin
QZQuing Zhu Zhu
Quing Zhu Zhu
Breast cancer is the second leading cause of death for women in the United States.1 Diffuse optical tomography (DOT) and diffuse optical spectroscopy are functional imaging modalities being explored for breast cancer diagnosis and treatment prediction.2 – 9 DOT provides quantitative estimations of oxygenated and deoxygenated hemoglobin concentrations calculated from reconstructed optical absorption maps of breast lesions. Hemoglobin concentrations are directly related to tumor angiogenesis, a hallmark of cancer. Since diffused light suffers from poor lesion localization and inaccurate target quantification due to intense scattering, image reconstruction is often guided by another high-resolution imaging modality, such as ultrasound (US),6 magnetic resonance imaging,8,9 or x-ray,10 which provide structural information about the tumor. While DOT guided by other modalities can significantly reduce the number of voxels with unknown optical properties for more accurate reconstruction,7 image artifacts caused by outlier measurements due to wavelength-dependent tissue heterogeneity, bad coupling between tissue and sources and detectors, and patient motion or operator hand motion can distort the reconstructed images. Several experimental and modeling approaches have been developed for system calibration of optical source strengths, detection channel gains and phase shifts,11 – 13 source and detector (optodes) position errors, and coupling errors between skin and optodes.12,14 – 17 For correcting motion artifacts, different algorithms have been proposed, including cubic spline interpolation,18 adaptive Kalman filtering,19 and wavelet-based motion artifact removal.20 To improve the imaging quality, projection error-based adaptive regularization techniques have been employed, which outperform standard Tikhonov regularization.21 However, these approaches do not compensate for wavelength-dependent problems. For example, the 740-nm wavelength is prone to measurement errors from tissue heterogeneity caused by dark skin and skin pigment. As another example, the 830-nm wavelength has lower signal to noise ratio at longer source and detector distances due to the reduced sensitivity of photomultiplier tube (PMT) detector beyond 800 nm.

22 April 2019 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
SXShiqi Xu
Shiqi Xu
KUK. M. Shihab Uddin
K. M. Shihab Uddin
QZQuing Zhu Zhu
Quing Zhu Zhu
Ultrasound (US)-guided diffuse optical tomography (DOT) is a promising low-cost imaging technique for diagnosis and assessment of breast cancer. US-guided DOT is best implemented in reflection geometry, which can be co-registered with US pulse-echo imaging and also minimizes the tissue depth for adequate light penetration. However, due to intense light scattering, the DOT reconstruction problem is ill-posed. In this communication, we describe a new non-linear Born iterative reconstruction method with US-guided depth-dependent l1 sparse regularization for improving DOT reconstruction by incorporating a priori lesion depth and shape information from the co-registered US image. Our method iteratively solves the inverse problem by updating the photon-density wave using the finite difference method, computing the weight matrix based on Born approximation, and reconstructing the absorption map using the fast iterative shrinkage-thresholding optimization algorithm (FISTA). We validate our method using both phantom and patient data and compare the results with those using the first order linear Born method. Phantom experiments demonstrate that the non-linear Born method provides more accurate target absorption reconstruction and better resolution than the linear Born method. Clinical studies on 20 patients show that non-linear Born reconstructs more realistic tumor shapes than linear Born, and improves the malignant-to-benign lesion contrast ratio from 2.73 to 3.07, which is a 12.5% improvement. For lesions approximately more than 2.0 cm in diameter, the average malignant-to-benign lesion contrast ratio is increased from 2.68 to 3.31, which is a 23.5% improvement.