Claudia Ottardi

Claudia Ottardi

Auto-generated profile, based on publicly available information

Claudia Ottardi

Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "G. Natta", Politecnico di Milano, Milan, Italy

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 November 2016 in European Spine Journal
Verified
Journal Article
Closed access
PDF file
ALAndrea Luca
Andrea Luca
COClaudia Ottardi
Claudia Ottardi
MSMaurizio Sasso
Maurizio Sasso
LPLiliana Prosdocimo
Liliana Prosdocimo
LBLuigi La Barbera
Luigi La Barbera
TVTomaso Villa
Tomaso Villa

20 January 2017 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
TBTito Bassani
Tito Bassani
COClaudia Ottardi
Claudia Ottardi
FCFrancesco Costa
Francesco Costa
MBMarco Brayda-Bruno
Marco Brayda-Bruno
HWHans-Joachim Wilke
Hans-Joachim Wilke
FGFabio Galbusera
Fabio Galbusera
The present study proposes a semi-automatic software approach to reconstruct 3D subject-specific musculoskeletal model of thoraco-lumbar spine from radiographic digitized images acquired with EOS system. The approach is applied to evaluate the intervertebral loads in 38 standing adolescents with mild idiopathic scoliosis. For each vertebra a set of landmarks was manually identified on radiographic images. Coordinates were processed calculating vertebral configuration in 3D space: i) location; ii) dimensions; iii) rotations. Spherical joints simulated discs, ligaments and facet joints. Body weight distribution, muscles forces and insertion points were placed according to physiologic-anatomical values. Inverse static analysis, calculating joints reactions in maintaining assigned spine configuration, was performed with AnyBody software. Reaction forces were computed to quantify intervertebral loads and correlation with the patient anatomical parameters was then checked. Preliminary validation was performed comparing the model outcomes with that obtained from other authors in previous modelling works and from in vivo measurements. The comparison with previous modelling works and in vivo studies partially fulfilled the preliminary validation purpose. However, minor incongruities were pointed out that need further investigations. The subjects intervertebral loads were found significantly correlated with the anatomical parameters in the sagittal and axial planes. Despite preliminary encouraging results that support model suitability, future investigations to consolidate the proposed approach are necessary. Nonetheless, the present method appears to be a promising tool that once fully validated could allow the subject-specific non-invasive evaluation of a deformed spine, providing supplementary information to the routine clinical examination and surgical intervention planning.

8 March 2016 in Medical Engineering & Physics
Verified
Journal Article
Closed access
COClaudia Ottardi
Claudia Ottardi
FGFabio Galbusera
Fabio Galbusera
ALAndrea Luca
Andrea Luca
LPLiliana Prosdocimo
Liliana Prosdocimo
MSMaurizio Sasso
Maurizio Sasso
TVTomaso Villa
Tomaso Villa
This study aims to analyze the destabilization produced following a pedicle subtraction osteotomy (PSO), with a calibrated numerical model. A 30° resection was created on L3 and L4. Range of Motion (ROM) and the force acting on the vertebral body were calculated. Osteotomies consistently increased the ROMs. In the intact model, 87% of the compressive load was acting on the vertebral bodies whereas in the destabilized models all the load was on the fractured surface. Osteotomies at both levels induced a marked instability but the PSO at L4 seemed to have a greater influence on the ROM. Despite the significant deformity corrections which could be achieved with PSO, this technique needs further analyses.

29 April 2017 in European Spine Journal
Verified
Journal Article
Closed access
PDF file
ALAndrea Luca
Andrea Luca
COClaudia Ottardi
Claudia Ottardi
ALAlessio Lovi
Alessio Lovi
MBMarco Brayda-Bruno
Marco Brayda-Bruno
TVTomaso Villa
Tomaso Villa
FGFabio Galbusera
Fabio Galbusera


1 April 2016 in Journal of Applied Biomaterials & Functional Materials
Verified
Journal Article
Open access
COClaudia Ottardi
Claudia Ottardi
LBLuigi La Barbera
Luigi La Barbera
LPLuca Pietrogrande
Luca Pietrogrande
TVTomaso Villa
Tomaso Villa
Background: Vertebral compression fractures occur in the thoracolumbar junction, causing the collapse of the vertebral body. For their treatment, vertebroplasty and kyphoplasty are used, but it is still unknown which technique is to be preferred. Methods: Finite element models of the thoracic spine were developed to evaluate the outcomes of vertebroplasty and kyphoplasty. A mild and severe collapse of T10 treated with vertebroplasty or kyphoplasty was studied. Stresses on the endplates and intradiscal pressures were extrapolated to determine the stress distribution in the adjacent structures. Results: The validation ensured a correct stiffness and a proper kinematic of each functional spinal unit. The results demonstrated that a consolidation following vertebroplasty caused slight variations of intradiscal pressures and stresses. If a kyphoplasty was performed after a mild collapse of the vertebral body, a 25% stress reduction on endplates was found. In cases of severe collapse, when a partial height restoration was achieved, a 15% stress reduction was obtained, while with a full recovery of the anterior wall of the collapsed vertebra, there was a further reduction of 40%. Conclusions: To reduce the stresses on the adjacent endplates and the risk of fracture, the results suggest a kyphoplasty is to be preferred, trying to restore the initial vertebral body height.