Fábio Henrique de Paulo Costa Santos

Fábio Henrique de Paulo Costa Santos

Auto-generated profile, based on publicly available information

Fábio Henrique de Paulo Costa Santos

Federal University of Uberlândia, Brazil

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2024 in Brazilian Oral Research
Verified
Journal Article
Open access
PDF file
TRThaís Cristina Mendes Rodrigues
Thaís Cristina Mendes Rodrigues
CRCaio Cesar Dias Resende
Caio Cesar Dias Resende
GMGuilherme Faria Moura
Guilherme Faria Moura
FSFábio Henrique de Paulo Costa Santos
Fábio Henrique de Paulo Costa Santos
GMGustavo Mendonça
Gustavo Mendonça
FNFlávio Domingues das Neves
Flávio Domingues das Neves
Computer-aided manufacturing (CAM) technology allows the use of different manufacturing techniques. This in vitro study aimed to evaluate the marginal fit of temporary restorations manufactured using conventional chairside methods, milling, and three-dimensional printing. Fifteen 3-element temporary restorations specimens were produced and categorized into three groups: non-digital, obtained using the conventional chairside method (GC); milled (GM); and three-dimensionally printed (GP). Marginal fit was assessed using scanning electron microscopy (SEM) performed under two conditions: one with only the central screw tightened, and the other with all three screws tightened. Horizontal misfit values were categorized as over-, equal-, and under-extended and qualitatively analyzed. Statistical analysis was performed using the Tukey–Kramer test (α=0.05). In the vertical assessment, three-dimensionally printed restorations demonstrated greater misfit than restorations obtained by milling and the conventional chairside method (P<0.05). In the horizontal assessment, the misfit in the GP group was significantly higher than that in the GM and GC groups. Restorations obtained using the conventional chairside method and milled provisional restorations showed more favorable results than three-dimensionally printed restorations.

19 October 2026
Verified
Thesis
Open access
FSFábio Henrique de Paulo Costa Santos
Fábio Henrique de Paulo Costa Santos
O estudo dos fatores capazes de influenciar a veracidade dos escaneamentos intraorais é essencial para aumentar a previsibilidade dos fluxos digitais em Implantodontia. O objetivo geral desta tese foi avaliar fatores que influenciam a veracidade do escaneamento intraoral em reabilitações implantossuportadas de arco total. Três objetivos específicos integraram este estudo. Objetivo específico 1: avaliar o efeito de ciclos repetidos de esterilização em autoclave sobre a estabilidade dimensional, os desvios superficiais e a adaptação marginal de scanbodies confeccionados em diferentes materiais. Objetivo específico 2: descrever e aplicar clinicamente um fluxo digital utilizando marcadores de posicionamento impressos em 3D para reabilitação implantossuportada bimaxilar de arco total. Objetivo específico 3: avaliar clinicamente o efeito de marcadores de posicionamento mucossuportados na veracidade do escaneamento intraoral de mandíbulas edêntulas reabilitadas com próteses implantossuportadas de arco total, bem como sua influência sobre o tempo clínico e a satisfação dos pacientes. A partir dos resultados obtidos, observou-se que ciclos repetidos de esterilização promoveram maiores desvios superficiais em scanbodies confeccionados em poliéter-éter-cetona (PEEK) quando comparados aos confeccionados em titânio, embora todos os componentes avaliados tenham permanecido dentro de limites clinicamente aceitáveis. A aplicação clínica de marcadores de posicionamento impressos em 3D mostrou-se viável e facilitou o alinhamento de conjuntos de dados digitais durante reabilitações implantossuportadas de arco total. Além disso, a utilização de marcadores de posicionamento mucossuportados promoveu aumento significativo da veracidade dos escaneamentos intraorais quando comparada às moldagens convencionais e aos escaneamentos realizados sem marcadores. Os fluxos digitais demandaram menor tempo clínico e proporcionaram maior satisfação aos pacientes quando comparados às técnicas convencionais. A utilização dos marcadores não aumentou o tempo de execução dos procedimentos e não influenciou negativamente a aceitação dos pacientes. Conclui-se que a veracidade do escaneamento intraoral para reabilitações implantossuportadas de arco total é influenciada tanto por fatores relacionados aos scanbodies quanto por estratégias empregadas durante a aquisição digital.

28 January 2026 in Brazilian Journal of Oral Sciences
Verified
Journal Article
Open access
APAna Vitoria Carvalho Pinto
Ana Vitoria Carvalho Pinto
CRCaio Cesar Dias Resende
Caio Cesar Dias Resende
FSFábio Henrique Paulo Costa Santos
Fábio Henrique Paulo Costa Santos
FRFabio Rizzante
Fabio Rizzante
GMGustavo Mendonça
Gustavo Mendonça
KZKarla Zancopé
Karla Zancopé
The purpose of this in vitro study was to evaluate the three-dimensional positioning of dental implants in casts obtained using conventional and digital impressions. A printed typodont with three digital mini-abutment analogues (Neodent, Curitiba, Brazil) and a scan body for mini-abutments (EFF – Dental Components, São Paulo, Brazil) was scanned five times (n=5) with two different scanners (Omnicam, CEREC, Dentsply Sirona and TRIOS 3, 3Shape) Five stone casts were fabricated from conventional impressions of the primary cast and then scanned using a laboratory scanner. Dental implant angulation and displacement were calculated. One cobalt-chrome metal framework was fabricated over the primary cast and seated over each obtained cast, and the misfit was assessed using scanning electron microscopy (SEM) For precision and trueness, data distribution and variance equality were analyzed using the Shapiro-Wilk and Levene’s tests, respectively. Precision was assessed using one-way ANOVA; trueness was assessed using two-way ANOVA. Both analyses were followed by Tukey’s test (α=0.05).The buccal-lingual angle showed no statistically significant differences, and the mesio-distal angle also showed no significant differences between cast types, although worse results were found for the distal implant. Implant displacement showed better results (lower values) for stone casts in all directions (P=.001). The prosthetic interface region showed better outcomes compared to the bevel feature of the scan body in all directions (P=.001). SEM evaluation showed no statistically significant differences in vertical misfit when all implant prosthetic screws were tightened in all groups. Printed casts present greater variability in 3D positioning and misfit of dental implants compared to conventional casts.

1 January 2025 in Brazilian Dental Journal
Verified
Journal Article
Open access
LRLuísa de Lanna Reis Rocha
Luísa de Lanna Reis Rocha
APAna Carolina Candelas Peixoto
Ana Carolina Candelas Peixoto
FSFábio Henrique de Paulo Costa Santos
Fábio Henrique de Paulo Costa Santos
CSCarlos José Osé Soares
Carlos José Osé Soares
GMGustavo Mendonça
Gustavo Mendonça
KZKarla Zancopé
Karla Zancopé
Resumo Este estudo in vitro avaliou o impacto de três distâncias entre implantes (7,14 e21 mm) na veracidade e distorção superficial de modelos gerados por meio de escaneamento intraorais, bem como a desadaptação de estruturas fresadas, analisada por microscopia eletrônica de varredura (MEV). A desadaptação na interface entre as estruturas e os intermediários protéticos também foi mensurada por meio de radiografia digital e MEV. Três modelos com diferentes distâncias entre implantes foram escaneados (n = 10), e um escaneamento de referência para cada modelo foi obtido com scanner de bancada. A veracidade foi avaliada por meio de comparações tridimensionais (3D) das imagens. Cinco estruturas em cobalto-cromo foram fresadas para cada grupo, e as desadaptações nas faces mesial e distal de ambos os implantes foram avaliadas por MEV e radiografia digital. A análise estatística foi realizada com α = 0,05. Não foram encontradas diferenças significativas na veracidade 3D entre as diferentes distâncias entre os implantes (p = 0,373), nem nos valores de desadaptação mesial (p = 0,075) e distal (p = 0,720) do implante anterior. Da mesma forma, não houve diferenças significativas nos valores de desadaptação mesial (p = 0,103) ou distal (p = 0,426) do implante mais posterior. Foi identificada uma forte correlação entre as análises de desadaptação realizadas por radiografia e MEV (r de Pearson = 0,819; p = 0,045). A distância entre os implantes não influenciou significativamente a veracidade ou a adaptação das estruturas fresadas. Todas as estruturas apresentaram boa adaptação aos intermediários protéticos. A forte correlação entre as análises radiográficas e por MEV sugere que a radiografia digital é uma ferramenta confiável para detectar desadaptações entre estruturas fresadas e implantes.

1 January 2026 in Brazilian Dental Journal
Verified
Journal Article
Open access
APAna Carolina Candelas Peixoto
Ana Carolina Candelas Peixoto
LRLuísa de Lanna Reis Rocha
Luísa de Lanna Reis Rocha
FSFábio Henrique de Paulo Costa Santos
Fábio Henrique de Paulo Costa Santos
RMRodrigo Silva Moreira
Rodrigo Silva Moreira
FNFlávio Domingues das Neves
Flávio Domingues das Neves
KZKarla Zancopé
Karla Zancopé
This study investigated the influence of material, number, and bevel alignment of intraoral scan bodies (ISBs) on the trueness of digital impressions. A mandibular typodont missing the left first and second premolars and first molar was used. ISBs for Mini Conical Abutments varied according to material (polyetheretherketone [PEEK] or Titanium), number (2 or 3), and bevel alignment (buccal-aligned, lingual-aligned, or misaligned). Each group was scanned once with a laboratory scanner to obtain the reference model and ten times with an intraoral scanner (N=10). STL files were aligned and compared using 3D overlay software to assess trueness. Statistical analysis was performed at a 5% significance level. Since assumptions of normality and homogeneity of variance were violated, a Generalized Linear Model (GLM) with 1,000 bootstrap resamples was applied. The dependent variable was discrepancy (µm), and the independent variables included material, number, and bevel alignment. Holm's post hoc test was used for pairwise comparisons, with effect sizes calculated using adjusted omega squared (ω²) for main effects and Cohen’s d for interactions. All factors significantly influenced trueness, with the strongest effect observed when variables interacted simultaneously. Titanium demonstrated superior performance compared with PEEK, although the effect size was small. Two ISBs showed lower mean discrepancy and variability than three, indicating a moderate effect. Regarding bevel alignment, buccal and misaligned orientations performed better than lingual alignment, which presented the least favorable outcomes. These findings indicate that the trueness of digital impressions is multifactorial, with material, number, and alignment of ISBs interacting to play a crucial role.