The semiconductor minority carrier lifetime contains information about several important material properties, including Shockley–Read–Hall defect levels/concentrations and radiative/Auger recombination rates, and the complex relationships between these parameters produce a non-trivial temperature-dependence of the measured lifetime. It is tempting to fit temperature-dependent lifetime data to extract the properties of the Shockley–Read–Hall recombination centers; however, without a priori knowledge of the distribution of the Shockley–Read–Hall states across the bandgap, this fit problem is under-constrained in most circumstances. Shockley–Read–Hall lifetime data are not well-suited for the extraction of Shockley–Read–Hall defect levels but can be used effectively to extract minority carrier recombination lifetimes. The minority carrier recombination lifetime is observed at temperatures below 100 K in a Si-doped n-type InGaAs/InAsSb superlattice, and deviation from its expected temperature-dependence indicates that the capture cross section of the defect associated with Si-doping has an activation energy of 1.5 meV or a characteristic temperature of 17 K. This lower temperature regime is also preferrable for the analysis of the physics of defect introduction with displacement-damage-generating particle irradiation.
16 October 2024 in IEEE Journal of Selected Topics in Quantum Electronics
We demonstrate monolithically grown germanium-tin (GeSn) on silicon avalanche photodiodes (APDs) for infrared light detection. A relatively thinner Ge buffer design was adopted to allow effective photo carriers to transport from the GeSn absorber to the Si multiplication layer such that clear punch-through behavior and a saturated primary responsivity of 0.3 A/W at 1550 nm were observed before avalanche breakdown in GeSn/Si APDs for the first time. The spectral response covers 1500 to 1700 nm. The measured punch-through and breakdown voltages are 15 and 17 V, respectively. Undisputed multiplication gain was obtained with the maximum value of 4.5 at 77 K, and 1.4 at 250 K, directly in reference to the saturated primary responsivity from the same device rather than a different GeSn p-i-n photodiode in previous reports. A peak responsivity was measured as 1.12 A/W at 1550 nm and 77 K.
InAsSbBi nBn photodetectors are demonstrated that are lattice-matched to the underlying GaSb substrate with a 4.32 μm wavelength cutoff at 150 K that is 0.3 μm longer than that of lattice-matched InAsSb at this temperature reflecting a 0.5% Bi mole fraction in the InAsSbBi active region. A low growth temperature was utilized to facilitate the incorporation of Bi, resulting in a minority carrier lifetime on the order of 24 ns in the InAsSbBi active region. Nevertheless, the detectors exhibit a quantum efficiency of 17% at 3.3 μm wavelength with a dark current density of 50 μA/cm2 at 150 K and −0.4 V bias and the strong photoresponse turn-on characteristic of a random alloy at 4.32 μm wavelength and 150 K. A shot noise-equivalent irradiance analysis indicates that this detectors' dark-current-limited noise-equivalent irradiance of 1012 cm−2 s−1 is two orders of magnitude greater than the Rule 07 expectation for this cutoff, and dark-current-limited shot noise-equivalent irradiance performance transitions to photon-limited at 1.7 × 1015 photons/cm2 s.
GeSn-based avalanche photodiode operating in shortwave infrared wavelength was demonstrated in this work. A separate absorption and charge multiplication structure was employed to take advantage of long wavelength absorption in GeSn and low impact ionization ratio of Si. Due to lattice mismatch between Si and GeSn that would degrade GeSn material quality if with direct growth, a 240-nm-thick Ge buffer was utilized, which simultaneously allows for the transporting photo generated electrons from the GeSn absorber to Si multiplication layer. Spectral response showed the cutoff wavelength beyond 2.1 μm at room temperature. Dark current and capacitance–voltage measurements indicated a punch-through voltage of −10 V. The measured responsivities were 0.55 and 0.34 A/W under 1.55 and 1.9 μm excitation lasers, respectively. The maximum gain was obtained as 3.44 at 77 K under 1.9 μm laser. Even at 250 K, the calculated gain was greater than unity. Simulation of the electric field distribution revealed that the GeSn is partially depleted at operating voltages, which can be improved by reducing the background doping levels in the GeSn absorber and Ge buffer layers.
A minority carrier lifetime of 2.7 ns is measured at 77 K for a GeSn/SiGeSn single quantum well using time-resolved photoluminescence, and subsequent analyses indicate that the lifetime is Auger-limited. The 77 K lifetime is evaluated as a function of stepwise dose of 63 MeV proton irradiation up to a fluence of 1.5 × 1012 p+/cm2 with no discernable reduction in the observed lifetime, which implies that the lifetime damage factor slope to 63 MeV proton irradiation is not greater than 2 × 10−5 cm2/s. Steady-state photoluminescence is used to evaluate the total luminescence output as a function of excitation, yielding a 2/3 power law slope consistent with Auger-limited recombination. The observed Auger-limited behavior is consistent with reports of high p-type background carrier concentration in these alloys. The temperature dependence of the steady-state photoluminescence spectra also provides the Einstein single oscillator model parameters for the ground state transition energy and Urbach energy of the GeSn quantum well.
The effects of 63 MeV proton and 60Co gamma irradiation on the operation of 4.3 μm cutoff nBn photodetectors are demonstrated separately, and both are shown to yield a total ionizing dose (TID) effect. The effect is shown here in an InAsSbBi nBn detector and has been observed in other bulk alloy nBn detectors, and is unusual as it is notably absent in superlattice nBn detectors. The non-antireflection coated detectors exhibit a pre-radiation quantum efficiency of 17% at 3.3 μm wavelength and a dark current density of 50 μA/cm2, or roughly 300× the Rule 07 expectation, at their ideal operating voltage of −0.4 V bias at 150 K. Step-wise proton irradiation and in situ measurement indicate that the dark current increases to about 400× Rule 07 at the highest proton dose level of 150 krad(Si) (9.10 × 1011 p+/cm2), while the quantum efficiency is degraded at a relatively faster rate than the majority of analogous detectors characterized by our lab. Both the photocurrent and dark current are also shown to exhibit a turn-on voltage magnitude reduction of 100 mV following either gamma or proton irradiation, a trend which is attributable to negative trapped charge at the barrier interface (TID effect). This theory is further supported by an observed capacitance density magnitude reduction with dose and affirmed with Silvaco TCAD simulations. Following both proton exposure and subsequent anneal and gamma exposure and subsequent anneal; dark current, photocurrent, and CV all approach their pre-radiation baseline values.