Convergence of Smart Sensors Institute, Dong-Eui University, Busan, Republic of Korea; Department of Radiological Science, Dong-Eui University, Busan, Republic of Korea
Auto-generated profile, based on publicly available information
Yun-Sik Yu
Convergence of Smart Sensors Institute, Dong-Eui University, Busan, Republic of Korea; Department of Radiological Science, Dong-Eui University, Busan, Republic of Korea
Zinc oxide (ZnO) thin films were prepared onto glass substrates at moderately low growth temperature by two-stage spray pyrolysis technique. The effects of growth temperature on structural, optical and acetone detection properties were investigated with X-ray diffractometry, a UV–visible spectrophotometer, photoluminescence (PL) spectroscopy and a homemade gas sensor testing unit, respectively. All the films are polycrystalline with a hexagonal wurtzite phase and exhibit a preferential orientation along [002] direction. The film crystallinity is gradually enhanced with an increase in growth temperature. The optical measurements show that all the films are physically highly transparent with a transmittance greater than 82% in the visible range. The band gap of the film is observed to exhibit a slight red shift with an increasing growth temperature. The PL studies on the films show UV/violet PL band at ∼ 395 nm. Among all the films investigated, the film deposited at 250 °C demonstrates a maximum sensitivity of 13% towards 20 ppm of acetone vapors at 300 °C operating temperature.
30 April 2016 in Journal of the Korean Society of Radiology
A Survey on the Radiation Exposure Doses Reduction Plan through Dose Index Analysis in the Pediatric Brain Computed Tomography Picture archiving communication system;Electronic medical record;Computed tomography dose index;Standard diagnostic reference level; In this study, the proposal to seek ways to reduce the amount of radiation is drawn by comparing and analyzing CT Dose Index(CTDI) on the pediatric head CT which was performed at the busan regional hospitals, to the national diagnostic reference levels. As a result, it was appeared to exceed the amount of the dose recommendation in order of hospital, general hospital and senior general hospital in the hospital-specific classification and from 2 to 5 year, from 1 month to 1 year and from 6 to 10 year in the age-specific classification. In addition, the amount of the dose recommendation was exceed in order of helical, axial and volume in the scan-specific classification. As the results of the scan range reset to match the diagnostic reference level, the dose reduction showed 11.68%, 15.79% and 20.66% in senior general hospital, general hospital and hospital respectively. In the results of analysing patient average scan ranges which does not deviate from the guideline of patient dose recommendation, there was age of 1 month to 1 year, 2 to 5 year and 6 to 10 year of $03.2{\pm}11.8mm$, $110.5{\pm}14.5mm$, and $117.8{\pm}17.2mm$ respectively.
29 February 2016 in The Journal of Korean Institute of Information Technology