Magnetic particle imaging (MPI) is a novel tracer-based in vivo imaging modality allowing quantitative measurements of the spatial distributions of superparamagnetic iron oxide (SPIO) nanoparticles in three dimensions (3D) and in real time using electromagnetic fields. However, MPI lacks the detection of morphological information which makes it difficult to unambiguously assign spatial SPIO distributions to actual organ structures. To compensate for this, a preclinical highly integrated hybrid system combining MPI and Magnetic Resonance Imaging (MRI) has been designed and gets characterized in this work. This hybrid MPI-MRI system offers a high grade of integration with respect to its hard- and software and enables sequential measurements of MPI and MRI within one seamless study and without the need for object repositioning. Therefore, time-resolved measurements of SPIO distributions acquired with MPI as well as morphological and functional information acquired with MRI can be combined with high spatial co-registration accuracy. With this initial phantom study, the feasibility of a highly integrated MPI-MRI hybrid systems has been proven successfully. This will enable dual-modal in vivo preclinical investigations of mice and rats with high confidence of success, offering the unique feature of precise MPI FOV planning on the basis of MRI data and vice versa.
17 August 2020 in IEEE Transactions on Medical Imaging
Non-invasive quantification of functional parameters of the cardiovascular system, in particular the heart, remains very challenging with current imaging techniques. This aspect is mainly due to the fact, that the spatiotemporal resolution of current imaging methods, such as Magnetic Resonance Imaging (MRI) or Positron Emission Tomography (PET), does not offer the desired data repetition rates in the context of real-time data acquisition and thus, can cause artifacts and misinterpretations in accelerated data acquisition approaches. We present a fast non-invasive and quantitative dual-modal in situ cardiovascular assessment using a hybrid imaging system which combines the new imaging modality Magnetic Particle Imaging (MPI) and MRI. This pre-clinical hybrid imaging system provides either a 0:5T homogeneous B0 field for MRI or a 2:2T=m gradient field featuring a Field- Free-Point for MPI. A comprehensive coil system allows in both imaging modes for spatial encoding, signal excitation and reception. In this work, 3-dimensional anatomical information acquired with MRI is combined with in situ sequentially acquired time-resolved 3D (i.e. 3D+t) MPI bolus tracking of superparamagnetic iron oxide nanoparticles. MPI data were acquired during a 21μl (40μmol(Fe)=kgBW) bolus tail vein injection under free-breathing with an ungated and non-triggered MPI scan with a repetition rate of 46 volumes per seconds. We successfully determined quantitative hemodynamics as 3D+t velocity vector estimations of a beating rat’s heart by analyzing 3 seconds of 3D+t MPI image data. The used hybrid system allows for MR-based MPI Field-of-View planning and cardiac crosssectional anatomy analysis, precise co-registration of dualmodal datasets, as well as for MPI-based hemodynamic functional analysis using an optical flow technique. We present the first in-vivo results of a new methodology, allowing for fast, non-invasive, quantitative and in situ hybrid cardiovascular assessment, showing its potential for future clinical applications.
Magnetic particle imaging (MPI) is a powerful and rapidly growing tomographic imaging technique that allows for the non‐invasive visualization of superparamagnetic nanoparticles (NPs) in living matter. Despite its potential for a wide range of applications, the intrinsic quantitative nature of MPI has not been fully exploited in biological environments. In this study, a novel NP architecture that overcomes this limitation by maintaining a virtually unchanged effective relaxation (Brownian plus Néel) even when immobilized is presented. This superparamagnetic magnetite architecture made of phenolic resin hollow spheres coated with Eu(III) containing silica nanoparticles (SMART RHESINs) was synthesized and studied. Magnetic particle spectroscopy (MPS) measurements confirm their suitability for potential MPI applications. Photobleaching studies show an unexpected photodynamic due to the fluorescence emission peak of the europium ion in combination with the phenol formaldehyde resin (PFR). Cell metabolic activity and proliferation behavior are not affected. Colocalization experiments reveal the distinct accumulation of SMART RHESINs near the Golgi apparatus. Overall, SMART RHESINs show superparamagnetic behavior and special luminescent properties without acute cytotoxicity, making them suitable for bimodal imaging probes for medical use like cancer diagnosis and treatment. SMART RHESINs have the potential to enable quantitative MPS and MPI measurements both in mobile and immobilized environments.
New possibilities offered by Magnetic Particle Spectroscopy (MPS) and Imaging (MPI) are increasingly being recognized and may accelerate the introduction of MPI into clinical settings. As MPI is a tracer‐based imaging method, the design and development of responsive tracers for functional imaging are particularly appealing. Here, Mn‐ferrite (MnxFe3‐xO4) nanoparticles with finely tuned magnetic properties and enzyme‐like capabilities are reported as potential multifunctional theranostic agents. By adjusting the Mn content in the iron oxide matrix, the magnetic particle imaging signal of different tracers can be tweaked, allowing for the simultaneous quantitative detection of two different tracers in a multi‐color approach. The Mn2FeO4 tracers exhibit potent enzyme‐like catalytic properties, enabling degradation of reactive oxygen species, including H2O2 and OH−. Due to the readily interchangeable oxidation states of Mn and Fe atoms in the crystal structure, a strong dependence of the magnetic properties is observed on H2O2 exposure, which can be exploited for sensing. This enables, for the first time, the sensing of reactive oxygen species based on magnetic particle spectroscopy and imaging, with sensitivity down to 25 µm H2O2 and complete sensor recovery over time. In summary, Mn‐ferrite nanoparticles hold promising potential for imaging, sensing, and degradation of disease‐relevant reactive oxygen species.
12 May 2025 in IEEE Transactions on Instrumentation and Measurement
Magnetic particle imaging (MPI) uses the nonlinear magnetization response of superparamagnetic iron-oxide nanoparticles (SPIONs) for fast, sensitive, and quantitative imaging of SPION distributions in biological systems. However, the SPIONs’ signal is overshadowed by the much larger excitation signal, necessitating the use of gradiometric receive coils, which often suffer from reduced homogeneity and adverse cross-talk with the MPI system. We develop a new high-sensitivity receive coil by extending the radial geometric design for gradiometers, where cancellation coil parts have larger diameter, thus providing stronger coupling to the excitation field. This enables us to both reduce cancellation coil windings and increase the winding density of the smaller-diameter pick-up coil part, achieving greater sensitivity and homogeneity. The developed mouse-sized receiveonly (Rx) coil is optimized for the use in Bruker’s preclinical MPI scanner and its performance is compared to the scanner’s built-in transmit-receive (TxRx) coil. Power transfer measurements and the particle signal-to-noise ratio show a sensitivity improvement of (20 – 21) dB in the range of (102 – 103) kHz compared to the TxRx coil. The sensitivity varies within ±9% across the field-ofview, providing higher homogeneity than standard gradiometers. With reconstructed images of SPION dilutions using perimag® particles, we show an iron limit-of-detection of 8.5 ng for the novel Rx coil, which is a ten-fold improvement compared to the original TxRx coil. The high sensitivity and homogeneity provided by the Rx coil will advance the application of MPI in preclinical research by enabling the visualization and quantification of lower iron concentrations, as well as providing higher spatial and temporal resolution.