1 July 2004 in Breast Cancer Research and Treatment
10 December 2010 in International Journal of Cancer
To overcome the limits of conventional microwave ablation, a new frequency spectrum above 6 GHz has been explored for low‐power and low collateral damage ablation procedure. A planar coaxial probe‐based applicator, suitable for easy insertion into the human body, was developed for our study to cover a wideband frequency up to 30 GHz. Thermal ablations with small input power (1–3 W) at various microwave frequencies were performed on nude mice xenografted with human breast cancer. Comparative study of ablation efficiencies revealed that 18‐GHz microwave results in the largest difference in the temperature rise between cancer and normal tissues as well as the highest ablation efficiency, reaching 20 times that of 2 GHz. Thermal profile study on the composite region of cancer and fat also showed significantly reduced collateral damage using 18 GHz. Application of low‐power (1 W) 18‐GHz microwave on the nude mice xenografted with human breast cancer cells resulted in recurrence‐free treatment. The proposed microwave ablation method can be a very effective process to treat small‐sized tumor with minimized invasiveness and collateral damages.
1 December 2016 in Electronics Letters
A 6–18 GHz gallium nitride (GaN) non‐uniform distributed amplifier (NDA) monolithic microwave integrated circuit with high power density is implemented with compact four‐way combined power. The drain lines and gate lines are shared among the combined NDAs. Sharing drain (or gate) lines reduces the drain (or gate) line length by half, while keeping the same characteristic impedances and eliminates bulky and lossy power combiners, such as Wilkinson combiners. The proposed four‐way NDA was fabricated using a commercial 0.25 μm GaN high electron mobility transistor (HEMT) process. It shows average continuous wave output power of 20.8 W and average associated gain of 10.7 dB from 6 to 18 GHz under 33 V drain bias. When pulsed input power and pulsed DC bias are simultaneously supplied to the NDA, the output power increases to 26 W, on average. To the best of the authors’ knowledge, the highest RF power and power density among the reported GaN power amplifiers with an octave bandwidth higher than the Ku‐band is represented in this work.
8 May 2006 in International Journal of Cancer
A developing method of cancer detection is to use electromagnetic waves to compare the dielectric properties of normal and cancerous tissue. Because most of the previous studies consisted of dielectric measurements taken ex‐vivo, this study investigated the advantages of in‐vivo measurements, obtained using the newly developed insertion‐type planar probe, through the measurements of cancer (MDA MB 231), which was cultivated and implanted into the mammary fat pad of nude mice. Reflection coefficients were obtained in the broadband frequency range from 0.5 to 30 GHz, from which broadband complex permittivity data was extracted. Complex permittivity, in addition to other parameters such as conductivity and characteristic frequency, were used to make comparisons between cancerous tissue, normal muscle tissue and fat tissue, as well as comparisons between in‐vivo and ex‐vivo measurements. This study investigated the suitability of in‐vivo cancer detection using microwaves with the newly developed insertion‐type planar probe. Results showed that both sensitivity and specificity of the current method was 97%. In addition, predictive values were 99% for the positive and 94% for the negative, thus greatly enhancing the practicality of this method. In conclusion, it was demonstrated that in‐vivo measurements are highly beneficial in studying the potential of microwaves as a diagnostic tool of breast cancer, especially in combination with the newly developed insertion‐type planar probe.
15 November 2018 in IEEE Transactions on Microwave Theory and Techniques
In this paper, a switchless dual-band, dual-mode power amplifier (PA) has been developed for multioctave operation. For the switchless dual-band operation, we proposed a new coupled-line-based diplexer structure. The proposed diplexer operates as a balun at high-band frequencies and the coupled line at low-band frequencies. To better understand the proposed diplexer structure, a detailed analysis is performed based on a coupled-line theory. The interstage and output-stage matching networks of the PA are designed by using the proposed diplexer. To maximize the power-added efficiency (PAE) of the designed PA, turn off the unused band PAs and decide the optimum off-state bias condition of transistors. The designed dual-band, dual-mode PA is fabricated with commercial 0.25-μm GaN HEMT process. The fabricated PA shows over 15-dB small-signal gain at 5-11 GHz in the low-band mode and 9-18 GHz in the high-band mode. The measured average output power and PAE are 35 dBm, 23% in the low-band mode and 37 dBm, 26% in the high-band mode.
1 April 2016 in Electronics Letters
A 6–18 GHz, 8.1 W gallium nitride (GaN) distributed amplifier (DA) monolithic microwave integrated circuit (MMIC) is presented with compact size. To accomplish high‐output power density with compact size, the last two sections of the DA consist of small‐sized FETs. This approach improves the output return loss and allows the drain line lengths to be reduced thereby increasing the drain cut‐off frequency and reducing circuit size, which results in increased gain and output power characteristics up to higher frequencies. Source via holes of GaN high electron mobility transistors (HEMTs) are also shared to reduce chip size. The proposed DA is implemented as a two‐stage DA using a commercial 0.25 µm GaN MMIC process. It shows 8.1 W average continuous wave output power and 6.8 dB average associated gain from 6 to 18 GHz under 36 V drain bias with 6.7 mm 2 chip area. The proposed DA obtains 1.21 W/mm 2 output power density and 1.02 dB/mm 2 gain density.