Kenneth J. Holton

Kenneth J. Holton

Auto-generated profile, based on publicly available information

Kenneth J. Holton

Department of Orthopedic Surgery, University of Minnesota, Minneapolis, Minnesota

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2022 in JBJS Essential Surgical Techniques
Verified
Journal Article
Closed access
DPDavid W. Polly
David W. Polly
KHKenneth J. Holton
Kenneth J. Holton
PSPaul O. Soriano
Paul O. Soriano
JSJonathan N. Sembrano
Jonathan N. Sembrano
CMChristopher T. Martin
Christopher T. Martin
KJKristen E. Jones
Kristen E. Jones
Background: Sacropelvic fixation is a continually evolving technique in the treatment of adult spinal deformity. The 2 most widely utilized techniques are iliac screw fixation and S2-alar-iliac (S2AI) screw fixation 1–3 . The use of these techniques at the base of long fusion constructs, with the goal of providing a solid base to maintain surgical correction, has improved fusion rates and decreased rates of revision 4 . Description: The procedure is performed with the patient under general anesthesia in the prone position and with use of 3D computer navigation based on intraoperative cone-beam computed tomography (CT) imaging. A standard open posterior approach with a midline incision and subperiosteal exposure of the proximal spine and sacrum is performed. Standard S2AI screw placement is performed. The S2AI starting point is on the dorsal sacrum 2 to 3 mm above the S2 foramen, aiming as caudal as possible in the teardrop. A navigated awl is utilized to establish the screw trajectory, passing through the sacrum, across the sacroiliac (SI) joint, and into the ilium. The track is serially tapped with use of navigated taps, 6.5 mm followed by 9.5 mm, under power. The screw is then placed under power with use of a navigated screwdriver. Proper placement of the caudal implant is vital as it allows for ample room for subsequent instrumentation. The additional point of pelvic fixation can be an S2AI screw or a triangular titanium rod (TTR). This additional implant is placed cephalad to the trajectory of the S2AI screw. A starting point 2 to 3 mm proximal to the S2AI screw tulip head on the sacral ala provides enough clearance and also helps to keep the implant low enough in the teardrop that it is likely to stay within bone. More proximal starting points should be avoided as they will result in a cephalad breach. For procedures with an additional point of pelvic fixation, the cephalad S2AI screw can be placed using the previously described method. For placement of the TTR, the starting point is marked with a burr. A navigated drill guide is utilized to first pass a drill bit to create a pilot hole, followed by a guide pin proximal to the S2AI screw in the teardrop. Drilling the tip of the guide pin into the distal, lateral iliac cortex prevents pin backout during the subsequent steps. A cannulated drill is then passed over the guide pin, traveling from the sacral ala and breaching the SI joint into the pelvis. A navigated broach is then utilized to create a track for the implant. The flat side of the triangular broach is turned toward the S2AI screw in order to help the implant sit as close as possible to the screw and to allow the implant to be as low as possible in the teardrop. The navigation system is utilized to choose the maximum possible implant length. The TTR is then passed over the guide pin and impacted to the appropriate depth. Multiplanar post-placement fluoroscopic images and an additional intraoperative CT scan of the pelvis are obtained to verify instrumentation position. Alternatives: The use of spinopelvic fixation in long constructs is widely accepted, and various techniques have been described in the past 1 . Alternatives to stacked S2AI screws or S2AI with TTR for SI joint fusion include traditional iliac screw fixation with offset connectors, modified iliac fixation, sacral fixation alone, and single S2AI screw fixation. Rationale: The lumbosacral junction is the foundation of long spinal constructs and is known to be a point of high mechanical strain 5–7 . Although pelvic instrumentation has been utilized to increase construct stiffness and fusion rates, pelvic fixation failure is frequently reported 8,9 . At our institution, we identified a 5% acute pelvic fixation failure rate over an 18-month period 10 . In a subsequent multicenter retrospective series, a similar 5% acute pelvic fixation failure rate was also reported 11 . In response to these findings, our institution changed its pelvic fixation strategies to incorporate multiple points of pelvic fixation. From our experience, utilization of multiple pelvic fixation points has decreased acute failure. In addition to preventing instrumentation failure, S2AI screws are lower-profile, which decreases the complication of implant prominence associated with traditional iliac screws. S2AI screw heads are also more in line with the pedicle screw heads, which decreases the need for excessive rod bending and connectors. The use of the techniques has been described in case reports and imaging studies 12–14 , but until now has not been visually represented. Here, we provide technical and visual presentation of the placement of stacked S2AI screws or open SI joint fusion with a TTR above an S2AI screw. Expected Outcomes: Pelvic fixation provides increased construct stiffness compared with sacral fixation alone 15–17 and has shown better rates of fusion 4 . However, failure rates of up to 35% 8,9 have been reported, and our own institution identified a 5% acute pelvic fixation failure rate 10 . In response to this, the multiple pelvic fixation strategy (stacked S2AI screws or S2AI and TTR for SI joint fusion) has been more widely utilized. In our experience utilizing multiple points of pelvic fixation, we have noticed a decreased rate of pelvic fixation failure and are in the process of reporting these findings 18,19 . Important Tips: The initial trajectory of the caudal S2AI screw needs to be as low as possible within the teardrop, just proximal to the sciatic notch. The starting point for the cephalad implant should be 2 to 3 mm proximal to the S2AI screw tulip head. This placement provides enough clearance and helps to contain the implant in bone. More proximal starting points may result in cephalad breach of the TTR. The use of a reverse-threaded Kirschner wire helps to prevent pin backout while drilling and broaching for TTR placement. If malpositioning of the TTR is found on imaging, removal and redirection is technically feasible. Acronyms and Abbreviations: S2AI = S2-alar-iliac TTR = triangular titanium rod CT = computed tomography AP = anteroposterior OR = operating room SI = sacroiliac DRMAS = dual rod multi-axial screw K-wire = Kirschner wire DVT = deep vein thrombosis PE = pulmonary embolism

1 January 2020 in JBJS Essential Surgical Techniques
Verified
Journal Article
Open access
DPDavid W. Polly
David W. Polly
KHKenneth J. Holton
Kenneth J. Holton
Background: Minimally invasive sacroiliac (SI) joint fusion is indicated for low back pain from the SI joint that is due to degenerative sacroiliitis and/or sacroiliac joint disruption. This technique is safe and effective in relieving pain uncontrolled by nonoperative management 1–4 . There is some controversy, but there continues to be increasing evidence of effectiveness. Description: This procedure is performed, with the patient under general anesthesia and in the prone position, using fluoroscopy or 3-dimensional (3D) navigation such as cone-beam computed tomographic (CT) imaging. After navigation setup, a navigated probe is used to approximate the desired location of each implant and trajectory. These positions are marked on the skin, and the skin is incised. A 3 to 5-cm lateral incision is made. The gluteal fascia is bluntly dissected to the outer table of the ilium. A guide pin is passed across the SI joint and into the center of the sacrum lateral to the neural foramina, which is confirmed with imaging. This is then drilled and broached. Triangular titanium rods are placed. Typically, 3 implants are placed, 2 in S1 and 1 in S2. Multiplanar postplacement imaging of the pelvis is obtained. The wound is irrigated and closed in layers. Alternatives: Nonsurgical alternatives have been reported to include pharmacological therapies, such as nonsteroidal anti-inflammatory drugs, therapeutic SI joint blocks 5 , and physical therapy, such as core stabilization, orthotics (SI belts), and radiofrequency ablation 1,2,6–8 . The surgical alternative is an open anterior or posterior approach with SI joint arthrodesis. The anterior approach differs by the resection of the SI joint cartilage, the use of a plate or screws across the joint for stabilization, and the packing of bone graft to facilitate fusion 9 . These are more morbid and have a much longer recovery. Rationale: Conservative management for SI joint pain is inadequate for all patients. Having 3 of 5 positive physical examination maneuvers 7 , having confirmatory diagnostic block(s) 10 , and ruling out the hip or spine as the pain generator provide a success rate of >80%. These patients have early and sustained clinically important and significantly improved outcomes across varying measures compared with conservative treatment 1–4,11,12 . Expected Outcomes: Patients can expect to experience decreased pain, reduced disability, increased daily function, and improved quality of life soon after the procedure is performed. These patients typically have an improvement of ≥50% in the Oswestry Disability Index score and a clinically significant decrease in visual analog pain scores 13 . The procedure appears durable through at least 5 years 14 . Complete pain relief is rare, but clinically important improvement is typical. Important Tips: Proper setup of the navigation system or fluoroscopy is needed to ensure accurate starting points. For 3D navigation, use a reference pin in the contralateral posterior superior iliac spine. Although navigation is used, radiographic images are made periodically to confirm proper placement of guide pins and implants. Images provide the greatest benefit when establishing navigation, after guide-pin placement when an outlet view allows for evaluation of pin depth, and after implant placement to confirm proper placement. Blood loss is generally low, but care should be taken to avoid vascular injury. Although rare, improper placement has led to injury of the superior gluteal artery 15 and iliac artery 16 . This can be avoided by staying in bone. Proper placement of the implant is imperative in this procedure. There is the potential for nerve injury with improper placement of the implant: an L5 nerve injury if the implant is too ventral or an S1 or S2 nerve injury if the implant is too deep and into the foramen. Revision surgery is commonly due to nerve root impingement and/or malpositioning. Preoperative 3D imaging is indicated when it is necessary to rule out differential diagnoses that mimic SI joint pain. This enables the surgeon to rule out intrapelvic pathology, assess sacral bone density 17 , and identify dysmorphic sacra or transitional vertebrae.

1 January 2020 in JBJS Case Connector
Verified
Journal Article
Closed access
BWBenjamin R. Williams
Benjamin R. Williams
ACAmy Calhoun
Amy Calhoun
KHKenneth J. Holton
Kenneth J. Holton
BKBrandon J. Kelly
Brandon J. Kelly
JSJonathan N. Sembrano
Jonathan N. Sembrano
Case: We present a long-term follow-up on a woman with otospondylomegaepiphyseal dysplasia (OSMED). At the age of 46 years, she is one of the oldest patients with the syndrome in the literature to date. We focus on the musculoskeletal anatomy and orthopaedic interventions over her lifetime. Conclusion: OSMED is a very rare syndrome. Arthritis and joint pains presented in her early adolescence and progressed to the point of requiring joint replacements by her 20s. Early intervention and monitoring improved the quality of life for this patient.

22 February 2024 in Indian Journal of Orthopaedics
Verified
Journal Article
Closed access
PDF file
AOAndrew F. Ormseth
Andrew F. Ormseth
KOKari Odland
Kari Odland
JHJason J Haselhuhn
Jason J Haselhuhn
KHKenneth J. Holton
Kenneth J. Holton
DPDavid W. Polly
David W. Polly

1 August 2023 in JAAOS: Global Research and Reviews
Verified
Journal Article
Open access
SCShea M. Comadoll
Shea M. Comadoll
KHKenneth J. Holton
Kenneth J. Holton
DPDavid W. Polly
David W. Polly
MSMichael W. Schmitz
Michael W. Schmitz
JHJason J Haselhuhn
Jason J Haselhuhn
JSJonathan N. Sembrano
Jonathan N. Sembrano
Introduction: We present a case series of proximal junctional failure due to a Chance-type fracture. Methods: This is a retrospective review of patients who developed proximal junctional kyphosis because of Chance-type proximal junctional failure after spinal fusion for adult spinal deformity. Results: Fifteen patients were identified (4M:11F). The average age was 61.4 years (range, 39 to 77). The mean time to fracture identification was 25.4 days (range, 3 to 65). The average number of levels instrumented was 6.7 (range, 2 to 17). No patients had antecedent trauma before fracture onset. In 67% of cases with a lumbar upper instrumented vertebra (UIV), there was overcorrection of lumbar lordosis (LL) and/or lower LL. The five cases with a lower thoracic UIV had undergone notable correction of preoperative thoracolumbar junction kyphosis. 14 of 15 patients were treated with extension of fusion. Pedicle screws at the fracture level were salvaged by changing to an anatomic trajectory. Conclusion: Continued pain at 6 to 12 weeks with radiographs showing an increased proximal junctional angle and cephalocaudal pedicle widening at the UIV should raise suspicion for this unique fracture pattern. A CT scan is recommended. Low bone density, LL and/or lower LL overcorrection, and selection of lower thoracic UIV in the setting of notable thoracolumbar junction correction may contribute to fracture risk.

23 October 2025 in Surgical Techniques Development
Verified
Journal Article
Open access
PDF file
DPDavid W. Polly
David W. Polly
KHKenneth J. Holton
Kenneth J. Holton
PSPaul Brian Soriano
Paul Brian Soriano
JHJason J Haselhuhn
Jason J Haselhuhn
KOKari Odland
Kari Odland
KJKristen E. E Jones
Kristen E. E Jones
Background/Objectives: A variety of techniques for pedicle screw placement exist. Efficiency claims have varied, but limited data are available to support or refute these claims. Our goal was to study our screw placement efficiency, reporting real-time screw placement using O-arm 3D navigation. Methods: We prospectively enrolled patients from July 2019 to February 2022 who were undergoing primary procedures involving thoracolumbar pedicle and pelvic screw placement with O-arm navigation. Screw time began at the first placement of the navigated probe/awl and ended once the navigated screwdriver was removed from the screw head. Confirmatory 3D scans were performed to assess all screw placements. Results: The real-time average to place pedicle screws was 2 min 9 s (SD ± 1 min 5 s); for pelvic screws, this was 3 min 36 s. Screw placement was slightly faster in pediatric patients (2 min 3 s) vs. adults (2 min 24 s), p < 0.001. Screw placement was faster in the thoracic spine (2 min 2 s) vs. the lumbosacral spine (2 min 22 s), p < 0.001. Screw placement was faster in adolescent idiopathic scoliosis (2 min 0 s) vs. all other diagnoses (2 min 24 s), p < 0.001. Screw placement performed by a single attending surgeon (2 min 24 s) was no different from dual-surgeon placement(2 min 13 s), p = 0.35. Conclusions: Our screw placement time is shorter than previously published estimates, and has a very high accuracy rate. While there are variations in how time is reported compared to the previous literature, our study serves as a benchmark for real-time screw placement for future studies. The use of navigation technology for pedicle and pelvic screw placement can be efficient.