Christopher T. Martin

Christopher T. Martin

Auto-generated profile, based on publicly available information

Christopher T. Martin

Department of Orthopedic Surgery, University of Minnesota, Minneapolis, MN, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2020 in International Journal of Spine Surgery
Verified
Journal Article
Open access
PDF file
CMChristopher T. Martin
Christopher T. Martin
LHLucas Haase
Lucas Haase
PLPaul A. Lender
Paul A. Lender
DPDavid W. Polly
David W. Polly
Background Fusion of the sacroiliac (SI) joint as a treatment for low back pain remains controversial. The purpose of this manuscript is to review the current literature and clinical outcomes of SI joint fusion surgery. Methods We conducted a literature review and included studies with the term “sacroiliac joint fusion” that had at least 12 months of clinical follow-up, reported on minimally invasive techniques, and included patient-reported outcome measures. Results Two approach types (dorsal and lateral) and numerous different implant manufacturers were identified. Most studies included level 4 data, with a small number of level 2 prospective cohort studies and 2 prospective level 1 studies. Every reviewed study reported clinical benefit in terms of improved pain scores or improvement in validated disability measures. Complication rates were low. Conclusions Minimally invasive SI joint fusion provides clinically significant improvement in pain scores and disability in most patients, across multiple studies and implant manufacturers. Level of Evidence 5 Clinical Relevance Emerging evidence in support of SI joint fusion indicates that clinicians should examine the SI joint and include SI joint pain in their differential diagnosis for low back pain patients.

1 January 2022 in Journal of Neurosurgery: Spine
Verified
Journal Article
Closed access
PDF file
CMChristopher T. Martin
Christopher T. Martin
DPDavid W. Polly
David W. Polly
KHKenneth J. Holton
Kenneth J. Holton
JMJose E. San Miguel-Ruiz
Jose E. San Miguel-Ruiz
MAMelissa Albersheim
Melissa Albersheim
KJKristen E. Jones
Kristen E. Jones
OBJECTIVE: Pelvic fixation with S2-alar-iliac (S2AI) screws is an established technique in adult deformity surgery. The authors’ objective was to report the incidence and risk factors for an underreported acute failure mechanism of S2AI screws. METHODS: The authors retrospectively reviewed a consecutive series of ambulatory adults with fusions extending 3 or more levels, and which included S2AI screws. Acute failure of S2AI screws was defined as occurring within 6 months of the index surgery and requiring surgical revision. RESULTS: Failure occurred in 6 of 125 patients (5%) and consisted of either slippage of the rods or displacement of the set screws from the S2AI tulip head, with resultant kyphotic fracture. All failures occurred within 6 weeks postoperatively. Revision with a minimum of 4 rods connecting to 4 pelvic fixation points was successful. Two of 3 (66%) patients whose revision had less fixation sustained a second failure. Patients who experienced failure were younger (56.5 years vs 65 years, p = 0.03). The magnitude of surgical correction was higher in the failure cohort (number of levels fused, change in lumbar lordosis, change in T1–pelvic angle, and change in coronal C7 vertical axis, each p < 0.05). In the multivariate analysis, younger patient age and change in lumbar lordosis were independently associated with increased failure risk (p < 0.05 for each). There was a trend toward the presence of a transitional S1–2 disc being a risk factor (OR 8.8, 95% CI 0.93–82.6). Failure incidence was the same across implant manufacturers (p = 0.3). CONCLUSIONS: All failures involved large-magnitude correction and resulted from stresses that exceeded the failure loads of the set plugs in the S2AI tulip, with resultant rod displacement and kyphotic fractures. Patients with large corrections may benefit from 4 total S2AI screws at the time of the index surgery, particularly if a transitional segment is present. Salvage with a minimum of 4 rods and 4 pelvic fixation points can be successful.

1 January 2023 in Journal of Neurosurgery: Spine
Verified
Journal Article
Closed access
PDF file
CMChristopher T. Martin
Christopher T. Martin
KHKenneth J. Holton
Kenneth J. Holton
BEBenjamin D. Elder
Benjamin D. Elder
JFJeremy L. Fogelson
Jeremy L. Fogelson
AMAnthony L. Mikula
Anthony L. Mikula
DPDavid W. Polly
David W. Polly
OBJECTIVE: There are few prior reports of acute pelvic instrumentation failure in spinal deformity surgery. The objective of this study was to determine if a previously identified mechanism and rate of pelvic fixation failure were present across multiple institutions, and to determine risk factors for these types of failures. METHODS: Thirteen academic medical centers performed a retrospective review of 18 months of consecutive adult spinal fusions extending 3 or more levels, which included new pelvic screws at the time of surgery. Acute pelvic fixation failure was defined as occurring within 6 months of the index surgery and requiring surgical revision. RESULTS: Failure occurred in 37 (5%) of 779 cases and consisted of either slippage of the rods or displacement of the set screws from the screw tulip head (17 cases), screw shaft fracture (9 cases), screw loosening (9 cases), and/or resultant kyphotic fracture of the sacrum (6 cases). Revision strategies involved new pelvic fixation and/or multiple rod constructs. Six patients (16%) who underwent revision with fewer than 4 rods to the pelvis sustained a second acute failure, but no secondary failures occurred when at least 4 rods were used. In the univariate analysis, the magnitude of surgical correction was higher in the failure cohort (higher preoperative T1-pelvic angle [T1PA], presence of a 3-column osteotomy; p < 0.05). Uncorrected postoperative deformity increased failure risk (pelvic incidence–lumbar lordosis mismatch > 10°, higher postoperative T1PA; p < 0.05). Use of pelvic screws less than 8.5 mm in diameter also increased the likelihood of failure (p < 0.05). In the multivariate analysis, a larger preoperative global deformity as measured by T1PA was associated with failure, male patients were more likely to experience failure than female patients, and there was a strong association with implant manufacturer (p < 0.05). Anterior column support with an L5–S1 interbody fusion was protective against failure (p < 0.05). CONCLUSIONS: Acute catastrophic failures involved large-magnitude surgical corrections and likely resulted from high mechanical strain on the pelvic instrumentation. Patients with large corrections may benefit from anterior structural support placed at the most caudal motion segment and multiple rods connecting to more than 2 pelvic fixation points. If failure occurs, salvage with a minimum of 4 rods and 4 pelvic fixation points can be successful.

1 January 2022 in Journal of Neurosurgery: Spine
Verified
Journal Article
Closed access
PDF file
CMChristopher T. Martin
Christopher T. Martin
KHKenneth J. Holton
Kenneth J. Holton
KJKristen E. Jones
Kristen E. Jones
JSJonathan N. Sembrano
Jonathan N. Sembrano
DPDavid W. Polly
David W. Polly
OBJECTIVE: Pelvic fixation enhances long constructs during deformity surgery. Subsequent loosening of iliac screws and pain at the pelvis occur in as many as 29% of patients. Concomitant sacroiliac (SI) fusion may prevent potential pain and failure. The objective of this study was to describe a novel surgical technique and a single institution’s experience using bilateral SI fusion during adult deformity surgery with S2-alar-iliac (S2AI) screws and triangular titanium rods (TTRs) placed with navigation. METHODS: The authors reviewed open SI joint fusions with TTR performed between August 2019 and March 2020. All patients underwent lumbosacral fusion through a midline approach and bilateral S2AI pelvic fixation in the caudal teardrop, followed by TTR placement just proximal and cephalad to the S2AI screws using intraoperative CT imaging guidance. RESULTS: Twenty-one patients were identified who received 42 TTRs, ranging in size from 7.0 × 65 mm to 7.0 × 90 mm. Three TTRs (7%) were malpositioned intraoperatively, and each was successfully repositioned during index surgery without negative sequelae. All breaches occurred in a medial and cephalad direction into the pelvis. Incremental operative time for adding TTR averaged 8 minutes and 33 seconds per implant. CONCLUSIONS: Image-guided open SI joint fusion with TTR during lumbosacral fusion is technically feasible. The bony corridor for implant placement is narrower cephalad, and implants tend to deviate medially into the pelvis. Detection of malpositioned implant is aided with intraoperative CT, but this can be salvaged. A prospective randomized clinical trial is underway that will better inform the impact of this technique on patient outcomes.

1 October 2022 in JBJS Essential Surgical Techniques
Verified
Journal Article
Closed access
DPDavid W. Polly
David W. Polly
KHKenneth J. Holton
Kenneth J. Holton
PSPaul O. Soriano
Paul O. Soriano
JSJonathan N. Sembrano
Jonathan N. Sembrano
CMChristopher T. Martin
Christopher T. Martin
KJKristen E. Jones
Kristen E. Jones
Background: Sacropelvic fixation is a continually evolving technique in the treatment of adult spinal deformity. The 2 most widely utilized techniques are iliac screw fixation and S2-alar-iliac (S2AI) screw fixation 1–3 . The use of these techniques at the base of long fusion constructs, with the goal of providing a solid base to maintain surgical correction, has improved fusion rates and decreased rates of revision 4 . Description: The procedure is performed with the patient under general anesthesia in the prone position and with use of 3D computer navigation based on intraoperative cone-beam computed tomography (CT) imaging. A standard open posterior approach with a midline incision and subperiosteal exposure of the proximal spine and sacrum is performed. Standard S2AI screw placement is performed. The S2AI starting point is on the dorsal sacrum 2 to 3 mm above the S2 foramen, aiming as caudal as possible in the teardrop. A navigated awl is utilized to establish the screw trajectory, passing through the sacrum, across the sacroiliac (SI) joint, and into the ilium. The track is serially tapped with use of navigated taps, 6.5 mm followed by 9.5 mm, under power. The screw is then placed under power with use of a navigated screwdriver. Proper placement of the caudal implant is vital as it allows for ample room for subsequent instrumentation. The additional point of pelvic fixation can be an S2AI screw or a triangular titanium rod (TTR). This additional implant is placed cephalad to the trajectory of the S2AI screw. A starting point 2 to 3 mm proximal to the S2AI screw tulip head on the sacral ala provides enough clearance and also helps to keep the implant low enough in the teardrop that it is likely to stay within bone. More proximal starting points should be avoided as they will result in a cephalad breach. For procedures with an additional point of pelvic fixation, the cephalad S2AI screw can be placed using the previously described method. For placement of the TTR, the starting point is marked with a burr. A navigated drill guide is utilized to first pass a drill bit to create a pilot hole, followed by a guide pin proximal to the S2AI screw in the teardrop. Drilling the tip of the guide pin into the distal, lateral iliac cortex prevents pin backout during the subsequent steps. A cannulated drill is then passed over the guide pin, traveling from the sacral ala and breaching the SI joint into the pelvis. A navigated broach is then utilized to create a track for the implant. The flat side of the triangular broach is turned toward the S2AI screw in order to help the implant sit as close as possible to the screw and to allow the implant to be as low as possible in the teardrop. The navigation system is utilized to choose the maximum possible implant length. The TTR is then passed over the guide pin and impacted to the appropriate depth. Multiplanar post-placement fluoroscopic images and an additional intraoperative CT scan of the pelvis are obtained to verify instrumentation position. Alternatives: The use of spinopelvic fixation in long constructs is widely accepted, and various techniques have been described in the past 1 . Alternatives to stacked S2AI screws or S2AI with TTR for SI joint fusion include traditional iliac screw fixation with offset connectors, modified iliac fixation, sacral fixation alone, and single S2AI screw fixation. Rationale: The lumbosacral junction is the foundation of long spinal constructs and is known to be a point of high mechanical strain 5–7 . Although pelvic instrumentation has been utilized to increase construct stiffness and fusion rates, pelvic fixation failure is frequently reported 8,9 . At our institution, we identified a 5% acute pelvic fixation failure rate over an 18-month period 10 . In a subsequent multicenter retrospective series, a similar 5% acute pelvic fixation failure rate was also reported 11 . In response to these findings, our institution changed its pelvic fixation strategies to incorporate multiple points of pelvic fixation. From our experience, utilization of multiple pelvic fixation points has decreased acute failure. In addition to preventing instrumentation failure, S2AI screws are lower-profile, which decreases the complication of implant prominence associated with traditional iliac screws. S2AI screw heads are also more in line with the pedicle screw heads, which decreases the need for excessive rod bending and connectors. The use of the techniques has been described in case reports and imaging studies 12–14 , but until now has not been visually represented. Here, we provide technical and visual presentation of the placement of stacked S2AI screws or open SI joint fusion with a TTR above an S2AI screw. Expected Outcomes: Pelvic fixation provides increased construct stiffness compared with sacral fixation alone 15–17 and has shown better rates of fusion 4 . However, failure rates of up to 35% 8,9 have been reported, and our own institution identified a 5% acute pelvic fixation failure rate 10 . In response to this, the multiple pelvic fixation strategy (stacked S2AI screws or S2AI and TTR for SI joint fusion) has been more widely utilized. In our experience utilizing multiple points of pelvic fixation, we have noticed a decreased rate of pelvic fixation failure and are in the process of reporting these findings 18,19 . Important Tips: The initial trajectory of the caudal S2AI screw needs to be as low as possible within the teardrop, just proximal to the sciatic notch. The starting point for the cephalad implant should be 2 to 3 mm proximal to the S2AI screw tulip head. This placement provides enough clearance and helps to contain the implant in bone. More proximal starting points may result in cephalad breach of the TTR. The use of a reverse-threaded Kirschner wire helps to prevent pin backout while drilling and broaching for TTR placement. If malpositioning of the TTR is found on imaging, removal and redirection is technically feasible. Acronyms and Abbreviations: S2AI = S2-alar-iliac TTR = triangular titanium rod CT = computed tomography AP = anteroposterior OR = operating room SI = sacroiliac DRMAS = dual rod multi-axial screw K-wire = Kirschner wire DVT = deep vein thrombosis PE = pulmonary embolism

5 December 2024 in Global Spine Journal
Verified
Journal Article
Open access
CMChristopher T. Martin
Christopher T. Martin
SYSangwook Tim Yoon
Sangwook Tim Yoon
RARam Kiran Alluri
Ram Kiran Alluri
EBEdward C. Benzel
Edward C. Benzel
CBChris M. Bono
Chris M. Bono
ADAo Spine Knowledge Forum Degenerative
Ao Spine Knowledge Forum Degenerative
Study Design: Reliability study. Objectives: The radiographic diagnosis of non-union is not standardized. Prior authors have suggested using a cutoff of .9. The ICC from these high performing reviewers was .94 (.9; .97), SEM was .45 mm, and MD was 1.26 mm. Conclusions: The MD of 2.29 mm in our study group was not precise enough to support a cutoff of <1 mm ISPM as the sole measurement technique in screening for non-union after ACDF, and there was only moderate agreement amongst surgeons on fusion status based on dynamic radiographs. More stringent techniques are necessary to avoid mis-diagnosing non-union in clinical studies. Future studies should consider auditing measurements to identify clerical errors.