Rahul Karuvingal

Rahul Karuvingal

Auto-generated profile, based on publicly available information

Rahul Karuvingal


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 February 2026 in Energy and AI
Verified
Journal Article
Open access
KDKai Droste
Kai Droste
ASAron Schwartz
Aron Schwartz
KDKai Derzsi
Kai Derzsi
RKRahul Karuvingal
Rahul Karuvingal
TSThomas Schreiber
Thomas Schreiber
DMDirk Müller
Dirk Müller

10 April 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
RKRahul Karuvingal
Rahul Karuvingal
KDKai Droste
Kai Droste
LKLeon Kopka
Leon Kopka
ABArkadi Butenko
Arkadi Butenko
KDKai Derzsi
Kai Derzsi
DMDirk Müller
Dirk Müller
Transitioning to fourth and fifth Generation District Heating and Cooling (DHC) systems is vital for urban decarbonization but is impeded by a disconnect between static spatial planning and dynamic physical simulation. This ``modeling gap'' forces engineers into labor-intensive, manual workflows, hindering iterative design. This study introduces a workflow utilizing UESgraphs v2.0.0, a fully automated, open-source Python framework that generates simulation-ready digital twins directly from raw GIS data. The methodology integrates a graph-based topology generator with two simulation engines: Pandapipes for rapid quasi-static thermo-hydraulic simulation and the Modelica AixLib package for high-fidelity dynamic analysis. The workflow is validated on a district from the TransUrban.NRW living lab project in Germany, analyzing the expansion from four to forty-three buildings. Findings indicate the pre-processing effectively adapted the topology from a simple tree to a resilient multi-source ring grid. Comparing both engines revealed a critical trade-off between computational efficiency and transient physical accuracy. The static engine completed the 43-building annual simulation in 13 minutes using under 0.5 GB RAM. Conversely, the dynamic model successfully captured essential thermal inertia and transient behaviors but required over 7.4 hours—a 34-fold increase—and 13 GB RAM for initialization. Consequently, a hierarchical workflow leveraging static tools for rapid topological sizing and dynamic models for transient validation is essential. This open-source approach reduces modeling barriers, ensuring transparent, scalable, and reproducible district energy planning.