Lucia Flors

Lucia Flors

Auto-generated profile, based on publicly available information

Lucia Flors

Department of Radiology and Medical Imaging, University of Virginia Health System, Charlottesville, VA, USA

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2011 in RadioGraphics
Verified
Journal Article
Closed access
LFLucía Flors
Lucía Flors
CLCarlos Leiva-Salinas
Carlos Leiva-Salinas
IMIsmaeel M. Maged
Ismaeel M. Maged
PNPatrick T. Norton
Patrick T. Norton
AMAlan H. Matsumoto
Alan H. Matsumoto
KHKlaus D. Hagspiel
Klaus D. Hagspiel
Vascular malformations and tumors comprise a wide, heterogeneous spectrum of lesions that often represent a diagnostic and therapeutic challenge. Frequent use of an inaccurate nomenclature has led to considerable confusion. Since the treatment strategy depends on the type of vascular anomaly, correct diagnosis and classification are crucial. Magnetic resonance (MR) imaging is the most valuable modality for classification of vascular anomalies because it accurately demonstrates their extension and their anatomic relationship to adjacent structures. A comprehensive assessment of vascular anomalies requires functional analysis of the involved vessels. Dynamic time-resolved contrast material-enhanced MR angiography provides information about the hemodynamics of vascular anomalies and allows differentiation of high-flow and low-flow vascular malformations. Furthermore, MR imaging is useful in assessment of treatment success and establishment of a long-term management strategy. Radiologists should be familiar with the clinical and MR imaging features that aid in diagnosis of vascular anomalies and their proper classification. Furthermore, they should be familiar with MR imaging protocols optimized for evaluation of vascular anomalies and with their posttreatment appearances. Supplemental material available at http://radiographics.rsna.org/lookup/suppl/doi:10.1148/rg.315105213/-/DC1.

1 October 2009 in Radiology
Verified
Journal Article
Closed access
TRTomás Ripollés
Tomás Ripollés
MMMaría J. Martínez
María J. Martínez
JPJose M. Paredes
Jose M. Paredes
EBEsther Blanc
Esther Blanc
LFLucía Flors
Lucía Flors
FDFructuoso Delgado
Fructuoso Delgado
Quantitative measurements of bowel enhancement obtained by using contrast material–enhanced US correlate with severity grade determined at endoscopy. PurposeTo evaluate the effectiveness of visualization of vascularization at contrast material–enhanced ultrasonography (US) for assessment of the activity of Crohn disease, with severity grade determined at endoscopy as the reference standard. Materials and MethodsEthics committee approval and written informed consent were obtained. Sixty-one patients (age range, 21–67 years; median age, 36 years) who had Crohn disease underwent both colonoscopy and US, including color Doppler and contrast-enhanced US, prospectively. To assess the vascularization of the involved bowel loop in a region expected to be seen at colonoscopy, the contrast agent uptake was measured by using quantitative analysis of the enhancement in regions of interest. Measurement of contrast enhancement was assessed as the increase in wall brightness with respect to the baseline brightness. Results were compared with the severity grade determined at endoscopy by using the area under the receiver operating characteristic curve and logistic reg...

1 November 2015 in The American Journal of Cardiology
Verified
Journal Article
Closed access
JGJorge A. Gonzalez
Jorge A. Gonzalez
MLMichael J. Lipinski
Michael J. Lipinski
LFLucia Flors
Lucia Flors
PSPeter W. Shaw
Peter W. Shaw
CKChristopher M. Kramer
Christopher M. Kramer
MSMichael Salerno
Michael Salerno

1 March 2015 in Techniques in Vascular and Interventional Radiology
Verified
Journal Article
Closed access
KHKlaus D. Hagspiel
Klaus D. Hagspiel
LFLucia Flors
Lucia Flors
MHMichael Hanley
Michael Hanley
PNPatrick T. Norton
Patrick T. Norton

1 July 2014 in American Journal of Roentgenology
Verified
Journal Article
Closed access
PLPierre Lemercier
Pierre Lemercier
SMSilvia Paz Maya
Silvia Paz Maya
JPJames T. Patrie
James T. Patrie
LFLucía Flors
Lucía Flors
CLCarlos Leiva-Salinas
Carlos Leiva-Salinas
Glioblastoma and solitary metastatic lesions can be difficult to differentiate with conventional MRI. The use of diffusion-weighted MRI to better characterize peritumoral edema has been explored for this purpose, but the results have been conflicting. The purpose of this study was to test the hypothesis that the gradient of apparent diffusion coefficient (ADC) values in peritumoral edema--that is, the difference in ADC values from the region closest to the enhancing tumor and the one closest to the normal-appearing white matter--may be a marker for differentiating glioblastoma from a metastatic lesion. Forty patients, 20 with glioblastoma and 20 with a solitary metastatic lesion, underwent diffusion-weighted brain MRI before surgical resection. The ADC values were retrospectively collected in the peritumoral edema in three positions: near, an intermediate distance from, and far from the core enhancing tumor (G1, G2, and G3). The ADC gradient in the peritumoral edema was calculated as the subtractions ADCG3 - ADCG1, ADCG3 - ADCG2, and ADCG2 - ADCG1. The ADC values in the enhancing tumor, peritumoral edema, ipsilateral normal-appearing white matter, contralateral healthy white matter, and CSF were also collected. A gradient of ADC values was found in the peritumoral edema of glioblastoma. The ADC values increased from the region close to the enhancing tumor (1.36 ± 0.24 × 10(-3) mm(2)/s) to the area near the normal-appearing white matter (1.57 ± 0.34 × 10(-3) mm(2)/s). In metastatic lesions, however, those values were nearly homogeneous (p = 0.04). The ADC gradient in peritumoral edema appears to be a promising tool for differentiating glioblastoma from a metastatic lesion.

11 August 2011 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
NTNicholas Tustison
Nicholas Tustison
BABrian B. Avants
Brian B. Avants
LFLucia Flors
Lucia Flors
TATalissa A. Altes
Talissa A. Altes
ELEduard E. de Lange
Eduard E. de Lange
JGJames C. Gee
James C. Gee
Purpose: To develop an automated segmentation method to differentiate the ventilated lung volume on3He magnetic resonance imaging (MRI).Materials and Methods: Computational processing (CP) for each subject consisted of the following three essential steps: 1) inhomogeneity bias correction, 2) whole lung segmentation, and 3) subdivision of the lung segmentation into regions of similar ventilation. Evaluation consisted of two comparative analyses: i) comparison of the number of defects scored by two human readers in 43 subjects, and ii) simultaneous truth and performance level estimation (STAPLE) in 18 subjects in which the ventilation defects were manually segmented by four human readers.Results: There was excellent correlation between the number of ventilation defects tabulated by CP and reader #1 (intraclass correlation coefficient [ICC] = 0.86), CP and reader #2 (ICC = 0.85), and between the two readers (ICC = 0.97). The STAPLE results from the second analysis yielded the following sensitivity/specificity numbers: CP (0.898/0.905), radiologist #1 (0.743/0.897), radiologist #2 (0.501/0.985), radiologist #3 (0.898/0.848), and the first author (0.600/0.984).Conclusion: We developed and evaluated an automated method for quantifying the ventilated lung volume on3He MRI. The findings strongly indicate that our proposed algorithmic processing may be a reliable, automatic method for quantitating ventilation defects. J. Magn. Reson. Imaging 2011;.