1 November 2020 in Radiology
FSFor The Fleischner Society
For The Fleischner Society
+9
Due to technical advances in pulmonary MRI, the Fleischner Society offers its consensus recommendations for the clinical use of MRI in evaluating patients with common lung disorders. Pulmonary MRI provides structural and quantitative functional images of the lungs without ionizing radiation, but it has had limited clinical use due to low signal intensity from the lung parenchym...
1 March 2017 in Journal of Cystic Fibrosis
This pilot study evaluated the effect of short- and long-term ivacaftor treatment on hyperpolarized 3He-magnetic resonance imaging (MRI)-defined ventilation defects in patients with cystic fibrosis aged ≥12years with a G551D-CFTR mutation. Part A (single-blind) comprised 4weeks of ivacaftor treatment; Part B (open-label) comprised 48weeks of treatment. The primary outcome was change from baseline in total ventilation defect (TVD; total defect volume:total lung volume ratio). Mean change in TVD ranged from -8.2% (p=0.0547) to -12.8% (p=0.0078) in Part A (n=8) and -6.3% (p=0.1953) to -9.0% (p=0.0547) in Part B (n=8) as assessed by human reader and computer algorithm, respectively. TVD responded to ivacaftor therapy. 3He-MRI provides an individual quantification of disease burden that may be able to detect aspects of the disease missed by population-based spirometry metrics. Assessments by human reader and computer algorithm exhibit similar trends, but the latter appears more sensitive. www.clinicaltrials.gov identifier: NCT01161537.
11 August 2011 in Journal of Magnetic Resonance Imaging
Purpose: To develop an automated segmentation method to differentiate the ventilated lung volume on3He magnetic resonance imaging (MRI).Materials and Methods: Computational processing (CP) for each subject consisted of the following three essential steps: 1) inhomogeneity bias correction, 2) whole lung segmentation, and 3) subdivision of the lung segmentation into regions of similar ventilation. Evaluation consisted of two comparative analyses: i) comparison of the number of defects scored by two human readers in 43 subjects, and ii) simultaneous truth and performance level estimation (STAPLE) in 18 subjects in which the ventilation defects were manually segmented by four human readers.Results: There was excellent correlation between the number of ventilation defects tabulated by CP and reader #1 (intraclass correlation coefficient [ICC] = 0.86), CP and reader #2 (ICC = 0.85), and between the two readers (ICC = 0.97). The STAPLE results from the second analysis yielded the following sensitivity/specificity numbers: CP (0.898/0.905), radiologist #1 (0.743/0.897), radiologist #2 (0.501/0.985), radiologist #3 (0.898/0.848), and the first author (0.600/0.984).Conclusion: We developed and evaluated an automated method for quantifying the ventilated lung volume on3He MRI. The findings strongly indicate that our proposed algorithmic processing may be a reliable, automatic method for quantitating ventilation defects. J. Magn. Reson. Imaging 2011;.
11 August 2020 in Radiology
Emphysema index based on hyperpolarized xenon 129 diffusion MRI is introduced as a robust, nonionizing alternative to CT for quantifying emphysema burden in chronic obstructive pulmonary disease. Background Apparent diffusion coefficient (ADC) maps of inhaled hyperpolarized gases have shown promise in the characterization of emphysema in patients with chronic obstructive pulmonary disease (...
25 March 2017 in Skeletal Radiology
To assess reader performance and subjective workflow experience when reporting bone age studies with a digital bone age reference as compared to the Greulich and Pyle atlas (G&P). We hypothesized that pediatric radiologists would achieve equivalent results with each method while digital workflow would improve speed, experience, and reporting quality.
12 March 2018 in Journal of Biomechanical Engineering
Computational models are useful for understanding respiratory physiology. Crucial to such models are the boundary conditions specifying the flow conditions at truncated airway branches (terminal flow rates). However, most studies make assumptions about these values, which are difficult to obtain in vivo. We developed a computational fluid dynamics (CFD) model of airflows for steady expiration to investigate how terminal flows affect airflow patterns in respiratory airways. First, we measured in vitro airflow patterns in a physical airway model, using particle image velocimetry (PIV). The measured and computed airflow patterns agreed well, validating our CFD model. Next, we used the lobar flow fractions from a healthy or chronic obstructive pulmonary disease (COPD) subject as constraints to derive different terminal flow rates (i.e., three healthy and one COPD) and computed the corresponding airflow patterns in the same geometry. To assess airflow sensitivity to the boundary conditions, we used the correlation coefficient of the shape similarity (R) and the root-mean-square of the velocity magnitude difference (Drms) between two velocity contours. Airflow patterns in the central airways were similar across healthy conditions (minimum R, 0.80) despite variations in terminal flow rates but markedly different for COPD (minimum R, 0.26; maximum Drms, ten times that of healthy cases). In contrast, those in the upper airway were similar for all cases. Our findings quantify how variability in terminal and lobar flows contributes to airflow patterns in respiratory airways. They highlight the importance of using lobar flow fractions to examine physiologically relevant airflow characteristics.