Parth Sanjay Kumavat

Parth Sanjay Kumavat

Auto-generated profile, based on publicly available information

Parth Sanjay Kumavat

Department of Mechanical, Manufacturing and Biomedical Engineering, Trinity College, University of Dublin, Dublin, Ireland

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2022 in International Journal of Thermal Sciences
Verified
Journal Article
Open access
PKP.S. Kumavat
P.S. Kumavat
SASajad Alimohammadi
Sajad Alimohammadi
SOSeamus O'Shaughnessy
Seamus O'Shaughnessy

26 July 2023 in IEEE Transactions on Components, Packaging and Manufacturing Technology
Verified
Journal Article
Open access
PKParth S. Kumavat
Parth S. Kumavat
SASajad Alimohammadi
Sajad Alimohammadi
SOSeamus O'Shaughnessy
Seamus O'Shaughnessy
The development of current and next generation high performance electronic devices has led to miniaturization in more densely packed spaces. The increasing power levels has resulted in ever-increasing heat flux densities which necessitates the evolution of new liquid-based heat exchange technologies. Implementation of single-phase cooling systems using pulsating flow is viewed as a potential solution to the problems involving high energy density electronics. This work involves a combined experimental and numerical analysis of pulsating flows in a rectangular minichannel undergoing asymmetric sinusoidal flow pulsation formats. The minichannel design includes a heated bottom section approximated as a constant heat flux boundary by uniformly heating a 12.5 μm thick Inconel foil. Infrared thermography (IR) is used for thermal measurements of the heated boundary from the hydrodynamically and thermally developed region of the minichannel. A three-dimensional conjugate heat transfer ANSYS CFX model is used for simulations. Asymmetric sinusoidal pulsating flows in the form of leading and lagging profiles with Womersley number of 2.5 and a flow rate amplitude ratio of 0.5 and 3 are investigated. The rapid fluctuating characteristics of the asymmetric waveforms cause a sudden shift in the flow velocity profiles and the subsequent increased pressure drop shows an evolution of phase lag. The intensification of fluid momentum due to high oscillating flowrate amplitudes causes enhanced mixing in the near-wall and bulk regions of the channel, as evidenced by the wall temperature profiles. The presence of wall viscous forces leads to the phenomenon of annular effects which has been widely investigated in the literature for symmetric flow profiles. The wall and bulk temperature profiles tend to readily adjust to this rapidly fluctuating flow. The effect of high pulsation flow rate amplitude leads to a heat transfer enhancement of about 11% over the corresponding steady flow.

28 September 2022
Verified
Conference Paper
Closed access
PKParth. S. Kumavat
Parth. S. Kumavat
SASajad Alimohammadi
Sajad Alimohammadi
SOSeamus O'Shaughnessy
Seamus O'Shaughnessy
The development of current and next generation high performance electronic devices has led to smaller components in more densely packed spaces. The increasing power levels has resulted in ever-increasing heat flux densities which necessitates the evolution of new liquid-based heat exchange technologies. Pulsating flow in single-phase cooling systems is viewed as a potential solution to the problems involving high heat flux densities. This work involves an experimental analysis using infrared thermography (IR) of hydrodynamically and thermally developed pulsating flows in a rectangular minichannel undergoing asymmetric sinusoidal flow pulsation formats. The minichannel design includes a heated bottom section approximated as a constant heat flux boundary by uniformly heating a 12.5 µm thick Inconel foil, resulting in volumetric heat generation rates of up to 360 MW/m 3 . Asymmetric sinusoidal pulsating flows in the form of leading and lagging profiles with Womersley number of 2.59 and a fixed flow rate amplitude ratio 3 are investigated. The pulsating wall temperature profiles are recorded non-intrusively using a FLIR SC6000 high-speed, high resolution, infra-red camera. The rapid fluctuating characteristics of asymmetric waveforms causes a sudden shift in the flow velocity profiles and the subsequent increased pressure drop shows an evolution of phase lag. The intensification of fluid momentum due to high oscillating flowrate amplitudes causes enhanced mixing in the near-wall and bulk regions of the channel, shown by the wall temperature profiles for lagging and leading cases respectively. Although the presence of wall viscous forces leads to the phenomenon of annular effects which has been widely investigated in the literature for symmetric flow profiles. The wall and bulk temperature profiles tend to readily adjust to this rapidly fluctuating flow. The effect of high pulsation flow rate amplitude leads to a substantial heat transfer enhancement of about 28% over the steady flows.

2 June 2021
Verified
Book Chapter
Closed access
PDF file
PKParth S. Kumavat
Parth S. Kumavat
RBRichard Blythman
Richard Blythman
DMDarina B. Murray
Darina B. Murray
SOSeamus M. O’sHaughnessy
Seamus M. O’sHaughnessy

24 April 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
PKPrasad Kangude
Prasad Kangude
PKParth Sanjay Kumavat
Parth Sanjay Kumavat
DSD. W. Salter
D. W. Salter
DTDaniel Trimble
Daniel Trimble
SOSeamus O'Shaughnessy
Seamus O'Shaughnessy
Effective thermal management is critical for prismatic lithium-ion batteries operating at high C-rates, where localized heating at the tabs and strong temperature gradients across the cell can compromise performance, safety, and cycle life. This work presents an integrated cooling strategy that combines jet-assisted tab cooling with thin-film evaporation over the cell surfaces. Using a single 50 Ah prismatic lithium iron phosphate battery and Opteon SF-33 as the working fluid, three cooling configurations were experimentally investigated under 2C charging and discharging conditions: free jet impingement with non-immersed surfaces (Config_1, proposed), body immersion with free jets (Config_2), and full immersion with submerged jets (Config_3). Among these, the proposed free-jet/non-immersed configuration consistently delivered the lowest peak temperatures, with both tab and surface temperatures remaining below 30oC across the investigated flow rates. The free jet flow enhanced stagnation-point heat transfer at the tabs, while the formation of a stable evaporating liquid film over the large prismatic faces improved surface temperature uniformity and promoted lateral heat spreading. In contrast, immersion-based configurations suppressed evaporation and attenuated jet momentum, resulting in comparatively higher operating temperatures despite larger coolant inventories. Overall, the proposed configuration (Config_1) reduced peak temperatures and improved combined thermal-hydraulic performance by a factor of ~1.6-1.9 while requiring substantially less dielectric fluid compared to the fully immersion-based Config_3. These results demonstrate that combining targeted jet impingement cooling with surface-level evaporation provides an effective and scalable thermal management strategy for prismatic lithium-ion batteries operating at high C-rates in electric vehicles and stationary energy storage applications.