11 May 2022 in IEEE Transactions on Industrial Electronics
Discrete point interpolation has emerged as a prime candidate technology for dual-station accurate intersection in 3-D precise measurement. However, the operation is low-efficiency for capturing multiple reference points to measure a single target point. The quantitative model of linear small angle in the interpolation is proposed by analyzing the movement trajectories of laser beam and laser spot. An efficient method for 3-D precise measurement using laser spot traversal and target point interpolation is proposed to achieve accurate intersection without multiple approximations. The laser spot traverses the field of view of the camera to establish an interpolation grid. The target point inserts the traversal grid and can be aimed by laser beam in arbitrary position. The traversal step size is determined by the determining equation of linear small angle. The approach is time-efficient for capturing all measured points in the field of view. The experimental results show that the proposed method is suitable for multiple points and surface measurement.
24 December 2025 in IEEE Transactions on Instrumentation and Measurement
Accurate calibration of scanning probes is essential for ensuring the measurement precision of coordinate measuring machines (CMMs). However, most existing calibration methods rely on linear models, which are inadequate for compensating nonlinear errors inherent in scanning probes. Furthermore, these methods often overlook the form error of the ruby ball, which further limits calibration accuracy. To address these limitations, this paper proposes a high-precision calibration approach that compensates for both linear and nonlinear errors. For linear errors, we incorporate the wear-induced error of the ruby ball into the parameter identification process, resulting in a more comprehensive and accurate linear calibration model. For nonlinear errors, a novel Nonlinear Error Calibration Neural Network (NEC-NN) is proposed. NEC-NN employs the Regional Modulation Module (RMM) to encode probing direction and the Cascaded Multi-Head Attention Module (C-MHAM) to extract deep-level features, enabling the network to capture directiondependent nonlinear errors. Additionally, normal consistency and spherical surface constraints are integrated into the loss function, reducing the training complexity while improving the adaptability of the model. The CMM used in the experiments has a nominal maximum permissible error of 2 + L[mm]/400 μm. After calibrating the scanning probe using the proposed method, the probe’s maximum probing error on a standard sphere decreased to 0.42 μm, while the CMM’s actual maximum permissible error was reduced to 0.6 + L[mm]/400 μm, demonstrating that the proposed method can significantly improve the overall measurement accuracy of the CMM. The proposed approach provides a more reliable and practical solution for the calibration of CMM scanning probes, thereby enhancing the overall reliability and performance of CMM in industrial applications.
23 June 2025 in IEEE Transactions on Instrumentation and Measurement
Geometric errors in coordinate measuring machines (CMMs) significantly degrade measurement accuracy. While laser tracking interferometer (LTI)-based compensation methods are widely used due to their high efficiency, the limited precision of the existing positioning techniques restricts their application in ultrahigh-precision CMMs. To address these challenges, this study introduces an accurate and efficient geometric error compensation method that utilizes LTI positioning for ultrahigh-precision CMMs. The method begins with the development of a geometric error model that employs homogeneous transformation matrices (HTMs) to map end-position deviations to error parameters. A highly accurate and robust positioning algorithm for LTI is then designed, incorporating a two-step process: initial positioning through semidefinite programming (SDP) and fine-tuning using enhanced particle swarm optimization (EPSO). After parameter identification, geometric error compensation is applied based on the established model. The test experiments were conducted on a CMM with the nominal accuracy of $2\:\pm \: L$ [mm]/ $400 \: \:\mu $ m. The positioning results show that the proposed method achieves a distance mean absolute error of 0.10871, demonstrating superior precision over conventional methods. Additionally, the method exhibits excellent robustness and stability under noise interference. After compensation, precision validation results showed that the maximum detection error was reduced to $ 0.26\:\mu $ m, with length measurement errors within $0.5\:\pm \: L$ [mm]/ $400 \:\: \mu $ m. These results highlight substantial improvements in both measurement precision and operational performance. This research presents an effective solution for geometric error compensation in CMMs, offering enhanced performance for industrial measurement applications.
1 January 2026 in IEEE Transactions on Instrumentation and Measurement
12 January 2026 in IEEE Transactions on Instrumentation and Measurement
The simultaneous monitoring of intracranial pressure (ICP) and intracranial temperature (ICT) are essential processes for assessing neurocritical conditions and preventing secondary brain injury. This study develops a medical monitor employing the optical fiber sensing technique, with a wavelength-phase hybrid coding approach, to simultaneously measure pressure and temperature. The optical fiber sensor is configured with a Fabry-Pérot (F-P) cavity and a fiber Bragg grating (FBG). The F-P cavity is fabricated through precision cutting and polishing, showing the advantages of controllable performance and low cost. Aiming at the multi-feature spectrum demodulation, this work combined the discrete Fourier transform with a centroid peak-detection technique to propose a wavelength-phase calculation strategy. Experimentally measuring range of the designed monitor is -300~300mmHg with a sensitivity of 248.67pm/mmHg. The error of pressure was reduced to a lower level of 2.48% by using temperature compensation. Additionally, the study constructed ex vivo tissue and in vivo animal experiments designed to test the monitor's performance. The results show that the monitor can accurately measure ICP and brain temperature, and it exhibits rapid response characteristics compared to commercial monitors. Such merits show the great potential of the monitor in the diagnosis and surveillance of neurocritical care patients.
13 February 2026 in IEEE Transactions on Instrumentation and Measurement
Coordinate measuring machines (CMMs) are widely used in industrial freeform surface measurement due to their high precision. The measurement process primarily involves point sampling and surface reconstruction. In this process, the choice of sampling method directly affects measurement accuracy and efficiency. However, existing sampling methods lack task-specific optimization for downstream surface reconstruction, making it difficult to achieve optimal sampling. To address these challenges, this paper proposes a task-driven adaptive sampling network (TDS-Net), which optimizes sampling for surface reconstruction in an end-to-end manner. TDS-Net consists of three core modules: the Multi-Channel Fusion Module (MCFM), the Adaptive Sampling Module (ASM), and the Downstream Task Module (DTM). First, the freeform surface point cloud is mapped to a 2D height map and combined with Gaussian curvature information, which is fed into MCFM to fuse multi-scale geometric features and identify key regions. ASM then employs an encoder-decoder architecture to extract deep feature information and generate a sampling probability map. A reparameterization technique decouples the discrete sampling from the computational graph, ensuring gradient propagation and training stability. Finally, DTM performs surface reconstruction based on sampled points and jointly optimizes task loss and uniformity loss, improving reconstruction accuracy while preventing local clustering of sampling points. The experimental results show that, for freeform surface reconstruction, TDS-Net reduces RMSE and PV by 26.75% and 36.03%, respectively, compared with existing sampling methods. It achieves high reconstruction accuracy while maintaining robust and adaptive sampling strategies, offering an efficient and intelligent solution for complex surface measurement tasks.