Xinxi Xu

Xinxi Xu

Auto-generated profile, based on publicly available information

Xinxi Xu

Department of Medical Support Technology, Institute of Systematic Engineering, Academy of Military Science, Tianjin, 300161, PR China

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2022 in Environment International
Verified
Journal Article
Open access
WGWeiqi Guo
Weiqi Guo
YFYingying Fu
Yingying Fu
RJRui Jia
Rui Jia
ZGZhendong Guo
Zhendong Guo
CSChen Su
Chen Su
WYWang Zhong Yi
Wang Zhong Yi
Since December 2019, coronavirus disease (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has become a great challenge to the world's public health system. Nosocomial infections have occurred frequently in medical institutions worldwide during this pandemic. Thus, there is an urgent need to construct an effective surveillance and early warning system for pathogen exposure and infection to prevent nosocomial infections in negative-pressure wards. In this study, visualization and construction of an infection risk assessment of SARS-CoV-2 through aerosol and surface transmission in a negative-pressure ward were performed to describe the distribution regularity and infection risk of SARS-CoV-2, the critical factors of infection, the air changes per hour (ACHs) and the viral variation that affect infection risk. The SARS-CoV-2 distribution data from this model were verified by field test data from the Wuhan Huoshenshan Hospital ICU ward. ACHs have a great impact on the infection risk from airborne exposure, while they have little effect on the infection risk from surface exposure. The variant strains demonstrated significantly increased viral loads and risks of infection. The level of protection for nurses and surgeons should be increased when treating patients infected with variant strains, and new disinfection methods, electrostatic adsorption and other air purification methods should be used in all human environments. The results of this study may provide a theoretical reference and technical support for reducing the occurrence of nosocomial infections.

30 March 2022 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
XXXinwu Xie
Xinwu Xie
JMJinbiao Ma
Jinbiao Ma
HWHao Wang
Hao Wang
Zhen ChengZhen Cheng
Zhen Cheng
TLTie Li
Tie Li
XXXinxi Xu
Xinxi Xu
Traditional detection methods have shortcomings such as time-consumption and requirement of large instruments, which cannot meet the demands for on-site detection or analysis. Silicon nanowire-field-effect transistor (SiNW-FET) biosensors have the advantages of high speed, high sensitivity, strong specificity, and ease of integration. However, SiNW-FET biosensors also have some demerits: they are too sensitive, environmental factors such as light, temperature, and pH easily cause interference, and their performance uniformity needs to be calibrated in advance. In this work, we constructed a self-contained and integrated microfluidic nano-detection system containing a SiNW-FET biosensor for bio-detection and analysis. All analysis processes including liquid sample delivery, optical modulation, constant temperature control, signal amplification and data acquisition, and result display were automatically performed. In series tests including light-guided ones by analyzing various types of samples with an automatic sample injection mode, the system shows good stability and robustness. Its signal accuracy was verified using a commercial high-precision ammeter (R2 = 0.9988), too. The feasibility of the system for bio-detection was verified using simulant samples of the typical microorganism Mycobacterium tuberculosis with a limit of detection of 1.0 fg mL−1. Furthermore, the process of the binding-dissociation of antibody–protein pairs was analyzed using the system, demonstrating the potential for molecular interaction analysis. This system is highly integrated, small in size, and easy to carry, which will be developed into a portable device for on-site bio-detection and analysis of molecular interactions to enable environmental testing, medical research, food and agricultural safety, military medicine, etc.

19 February 2017 in Journal of Mechanical Science and Technology
Verified
Journal Article
Closed access
PDF file
XXXinxi Xu
Xinxi Xu
MYMeng Yang
Meng Yang
NJNan Jia
Nan Jia
DDDeguang Duan
Deguang Duan

26 June 2018 in Journal of Medical and Biological Engineering
Verified
Journal Article
Closed access
PDF file
RLRong Li
Rong Li
XXXin-Xi Xu
Xin-Xi Xu
YQYang Qiao
Yang Qiao
XZXiu-Guo Zhao
Xiu-Guo Zhao

12 February 2015 in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
Verified
Journal Article
Closed access
MYMeng Yang
Meng Yang
XXXinxi Xu
Xinxi Xu
WSWeihua Su
Weihua Su
DDDeguang Duan
Deguang Duan
CSChen Su
Chen Su
This paper aims at improving the dynamic performance of nonlinear vibration-reduction system of the tracked ambulance, hence increasing the comfort of the sick and wounded. Three main tools are used to achieve this goal. First, a multi-objective method for parameter identification based on the improved partitioning and dimensional increment precise integration method and NSGA-II is proposed to identify the parameters of the nonlinear vibration-reduction system. Then the global sensitivity of the parameters with respect to the system outputs is studied by using the Sobol method. This is followed by the selection of the optimization variables according to the calculation of parameter sensitivity. Finally, the dynamic performance is optimized by using genetic algorithm. In this paper the parameter identification method proposed and the dynamic performance optimization applied is verified adaptable and effective as the dynamic performance indices are greatly improved.

12 April 2018 in RSC Advances
Verified
Journal Article
Open access
PDF file
XXXinwu Xie
Xinwu Xie
TFTian Feng
Tian Feng
XHXiao Hu
Xiao Hu
TCTongxin Chen
Tongxin Chen
XXXinxi Xu
Xinxi Xu
Studies of liquid evaporation on a solid surface are useful for wettability phenomena-related research, and can be applied in a series of scientific and industrial areas. However, traditional methods are not easy to be intergrated into small size to monitor evaporation process of a micro-droplet. In this paper, a micro-electrode array was used to measure the impedance of an electrolyte droplet, indicating the dynamic process of evaporation. This method uses the relationship between concentration and conductivity of the water solution to dynamically monitor the evaporation process. The dynamic impedance results were compared to weight and imaging data of droplet evaporation and demonstrate high correlation coefficient of the earlier 90% part of the sodium chloride droplet evaporation process (R2 = 0.99). Our study proved that the height of the droplet will affect the impedance sensing result, and the solution used for droplet evaporation can be expanded to mixture of strong electrolyte solution such as phosphate buffered solution. Then the “impedance imaging” of the array monitored the evaporating speed differences of different sites of a sessile droplet. As the electrode array can be integrated into small size, this method is compatible for many other experimental systems and can be further used for evaporation studies and corresponding application areas.