Jinbiao Ma

Jinbiao Ma

Auto-generated profile, based on publicly available information

Jinbiao Ma

Zhejiang Key Laboratory of Intelligent Sensing Technology and Advanced Medical Instrument, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 September 2021 in ACS Sensors
Verified
Journal Article
Closed access
JMJinbiao Ma
Jinbiao Ma
MDManman Du
Manman Du
WCWang Can
Wang Can
XXXinwu Xie
Xinwu Xie
HWHao Wang
Hao Wang
MWMin Wu
Min Wu

24 January 2025 in Nature Communications
Verified
Journal Article
Open access
PDF file
XLXiaoyin Liu
Xiaoyin Liu
JMJinbiao Ma
Jinbiao Ma
YZYunrui Zhang
Yunrui Zhang
YXYi Xu
Yi Xu
YWYunxiao Wang
Yunxiao Wang
FZFenni Zhang
Fenni Zhang
Cellular glycosylation is crucial for cell recognition, signal transduction, and the development of various diseases, especially in tumor initiation, progression, and metastasis. Current glycosylation profiling methods normally involve laborious sample processing and labeling and lack in-situ quantitative analysis. Here, we present a direct optical method to investigate and quantify the glycan expression on single cells based on lectin-glycan kinetic quantification with plasmonic imaging. Three unlabeled lectins (WGA, SBA, ConA) are employed as probes to bind with specific glycans, and binding kinetics are assessed to determine glycosylation profiles. The result reveals cell-to-cell heterogeneity in glycosylation patterns. To demonstrate the capability of our method, the glycosylation profiling of four distinct cell lines is explored, showing obvious alterations in glycan expression related to tumor initiation, progression, and metastasis. This approach enables direct quantification of glycosylation and binding kinetics, providing insights into tumor cell glycosylation mechanisms and potential applications in disease diagnosis and treatment.

13 January 2022 in The Analyst
Verified
Journal Article
Closed access
PDF file
JMJinbiao Ma
Jinbiao Ma
GJGuanyu Jiang
Guanyu Jiang
QMQingqing Ma
Qingqing Ma
HWHao Wang
Hao Wang
MDManman Du
Manman Du
SCShixing Chen
Shixing Chen
Tuberculosis (TB), caused by infection with airborne Mycobacterium tuberculosis (MTB), seriously threatens human health and has become a public health problem of worldwide concern. To achieve effective control of TB, rapid and sensitive detection of MTB is particularly important. At present, the common detection methods for MTB cannot meet the requirements of speed, flexibility and portability simultaneously. In this work, a multichannel microfluidic chip was developed and packaged with an ultra-sensitive silicon nanowire field-effect-transistor biosensor. The fluid system was tested and optimized through simulation, and the best conditions were determined: the flow rate was 0.3 mL min−1 and the flow direction was perpendicular to a silicon nanowire. A one-way valve, a switching valve and a peristaltic pump were combined to establish a biosensor detection system to realize the automatic detection of TB samples. Then we systematically explained the factors affecting simulated exhaled breath condensate (SEBC) collection, and established and optimized the method for collection of SEBC from the perspective of collection volume and biological activity. The best collection conditions were determined for a 5 mm pipe diameter at 0 °C, and a sufficient sample volume was obtained in only 2 minutes for microfluidic detection. Then, the actual application value of the established collection method was further evaluated. Volunteers were recruited and this method was used to collect their exhaled breath condensate to analyze the collection effect. The system detected MTB in SEBC with good sensitivity (∼4 × 104 particles per mL). It is expected to be further integrated and miniaturized in the future to realize point-of-care testing.

9 January 2025 in ACS Nano
Verified
Journal Article
Closed access
DYDehong Yang
Dehong Yang
XLXiaoyin Liu
Xiaoyin Liu
JMJinbiao Ma
Jinbiao Ma
BCBaiqi Cui
Baiqi Cui
YWYunxiao Wang
Yunxiao Wang
FZFenni Zhang
Fenni Zhang

30 March 2022 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
XXXinwu Xie
Xinwu Xie
JMJinbiao Ma
Jinbiao Ma
HWHao Wang
Hao Wang
Zhen ChengZhen Cheng
Zhen Cheng
TLTie Li
Tie Li
XXXinxi Xu
Xinxi Xu
Traditional detection methods have shortcomings such as time-consumption and requirement of large instruments, which cannot meet the demands for on-site detection or analysis. Silicon nanowire-field-effect transistor (SiNW-FET) biosensors have the advantages of high speed, high sensitivity, strong specificity, and ease of integration. However, SiNW-FET biosensors also have some demerits: they are too sensitive, environmental factors such as light, temperature, and pH easily cause interference, and their performance uniformity needs to be calibrated in advance. In this work, we constructed a self-contained and integrated microfluidic nano-detection system containing a SiNW-FET biosensor for bio-detection and analysis. All analysis processes including liquid sample delivery, optical modulation, constant temperature control, signal amplification and data acquisition, and result display were automatically performed. In series tests including light-guided ones by analyzing various types of samples with an automatic sample injection mode, the system shows good stability and robustness. Its signal accuracy was verified using a commercial high-precision ammeter (R2 = 0.9988), too. The feasibility of the system for bio-detection was verified using simulant samples of the typical microorganism Mycobacterium tuberculosis with a limit of detection of 1.0 fg mL−1. Furthermore, the process of the binding-dissociation of antibody–protein pairs was analyzed using the system, demonstrating the potential for molecular interaction analysis. This system is highly integrated, small in size, and easy to carry, which will be developed into a portable device for on-site bio-detection and analysis of molecular interactions to enable environmental testing, medical research, food and agricultural safety, military medicine, etc.

21 December 2021 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
JMJinbiao Ma
Jinbiao Ma
GJGuanyu Jiang
Guanyu Jiang
QMQingqing Ma
Qingqing Ma
MDManman Du
Manman Du
HWHao Wang
Hao Wang
MWMin Wu
Min Wu
Tuberculosis (TB) remains a public health problem that cannot be ignored. The portable and efficient detection of Mycobacterium tuberculosis (MTB) is important for the effective control of this disease. However, current detection techniques do not meet the requirements for MTB detection in the actual environment and often require cumbersome detection steps that are time consuming and inflexible. In this study, a portable immunosensor to detect MTB in sputum was prepared and then subjected to interface characterizations, such as scanning electron microscopy, hydrophilic angle test, and fluorescence characterization. The source and gate voltage of the device were optimized and tested using a non-contact photoresponse. The results showed that the sensitivity of the sensor to luminance increases with the decrease in source voltage. The gate voltage can substantially improve the response of the immunosensor to the normalized current of protein and amplify the signal at least 1.6 times. The optimal voltage detection conditions of source voltage (0.3 V) and gate voltage (0.1 V) were also determined. Several common proteins present in simulated saliva were used for anti-interference tests, and the sensor exhibited good specificity. Finally, the dilution gradient of an actual TB sputum sample was optimized. In the absence of preconditioning, a double-blind experiment was used to distinguish between the sputum from patients with TB and healthy individuals to shorten the TB detection time to a few minutes. Compared with the hospital's conventional detection method using cultures, the proposed method can complete the detection in a shorter time. This study provides a new strategy for the portable diagnosis of TB.