Faezeh Atri

Faezeh Atri

Auto-generated profile, based on publicly available information

Faezeh Atri

Department of Prosthodontics School of Dentistry, Craniomaxillofacial Research Center Tehran University of Medical Sciences Tehran Iran

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 September 2022 in Clinical and Experimental Dental Research
Verified
Journal Article
Open access
SSSamin Sirous
Samin Sirous
ANArghavan Navadeh
Arghavan Navadeh
SESaeedeh Ebrahimgol
Saeedeh Ebrahimgol
FAFaezeh Atri
Faezeh Atri
Objectives: This systematic review aims to investigate the effect of different preparation designs on the marginal fit and fracture strength of ceramic occlusal veneers.Materials and Methods: Based on the PICO question and the search terms, an electronic search was performed in Google Scholar, PubMed (MEDLINE), Scopus, Cochrane Library, Web of Science, Science Direct, Wiley, Ovid, and SAGE for articles published up to July 2022. After including English in vitro studies that evaluated posterior ceramic occlusal overlays at the posterior with ceramic restorations by following the PRISMA statement, the extracted data was tabulated. The methodological quality of the included studies was evaluated. Risk of bias assessment was done independently by two authors using the modified MINORS scale.Results: About 3138 search results were screened, of which 22 were selected due to their titles. Twenty‐one full‐text articles were assessed for eligibility. Seventeen in‐vitro studies were finalized for the extraction of quantitative data. All 17 articles had a low risk of bias and were retained. The influencing items for evaluating the research were different in most studies; therefore, qualitative synthesis of the results was feasible. They generally included preparation design, material thickness, depth of preparation in the tooth, internal divergence angle, and finish line. Meta‐analysis was not done due to heterogeneity of preparation types and evaluation methods. Results revealed that fracture resistance of occlusal veneers is higher than normal mastication force, and it is sufficient to prepare the occlusal surface, use a self‐etching primer for bonding, and an acceptable minimum ceramic thickness. The marginal discrepancy of occlusal veneers is clinically acceptable. However, this systematic review faces some limitations due to the lack of in vivo studies, different preparation designs in included studies, different follow‐ups, and lack of comprehensive explanations in articles.Conclusions: The preparation design of occlusal veneers influences both marginal adaptation and fracture resistance. Various preparation designs are proven to have clinically acceptable fracture strength and marginal adaptation.

14 June 2017 in Journal of Materials Science: Materials in Medicine
Verified
Journal Article
Closed access
PDF file
AAAbbas Azari
Abbas Azari
SNSakineh Nikzad
Sakineh Nikzad
AYArash Yazdani
Arash Yazdani
FAFaezeh Atri
Faezeh Atri
Abbas Fazel Anvari-YazdiAbbas Fazel Anvari-Yazdi
Abbas Fazel Anvari-Yazdi

20 February 2022 in Clinical and Experimental Dental Research
Verified
Journal Article
Open access
PDF file
SSSina Mohammadi Sadr
Sina Mohammadi Sadr
EAElham Ahmadi
Elham Ahmadi
MTMasoumeh Hasani Tabatabaei
Masoumeh Hasani Tabatabaei
SMSaba Mohammadi
Saba Mohammadi
FAFaezeh Atri
Faezeh Atri
Objectives: Restoration fit is one of the prerequisites of clinical durability. It is controversial as to whether computer‐assisted design/computer‐aided milling (CAD/CAM) or lost‐wax fabrication methods result in more fit metal‐ceramic crowns. This in‐vitro study was conducted to examine the internal fit of porcelain fused to metal crowns fabricated using CAD/CAM and lost‐wax techniques during fabrication stages (framework, porcelain, cementation) through digital triple scanning, replica weighting, and observation with electron microscopy.Material and methods: Twenty uniform resin dies of prepared first maxillary molars were randomly divided into two groups according to the fabrication technique: lost wax and CAD/CAM. The internal fit was measured in all steps of completing the crowns (framework, porcelain, and cementation) using different methods, including triple scanning, replica weighting, and scanning electron microscopy. The data were statistically analyzed using t test, Pearson, and repeated measures analysis of variance (α = .05).Results: Triple scanning revealed no difference in the internal fit of CAD/CAM and lost‐wax groups in all the fabrication steps (p > .05). The replica weighting method showed no difference between groups in the framework step (p > .05), while the internal fit was significantly better in the CAD/CAM group after porcelain application (p < .05). After cementation, electron microscopy measurements showed no difference between CAD/CAM and lost wax groups (p > .05). The Pearson correlation test showed no significant correlation between electron microscopy, replica weighing, and triple scanning methods (p > .05).Conclusion: According to scanning electron microscopy as the superior evaluation method, the internal fit of cobalt–chrome PFM crown of both CAD/CAM and lost wax groups was within the acceptable clinical range and there was no significant difference between them. Triple scanning revealed no difference in the internal fit of framework and porcelain steps but a better fit after cementation. According to replica weighting, the internal fit in the porcelain step was higher than the framework.

31 December 2020 in Dental and Medical Problems
Verified
Journal Article
Open access
EAElham Ahmadi
Elham Ahmadi
MTMasoomeh Hassani Tabatabaei
Masoomeh Hassani Tabatabaei
SSSina Sadr
Sina Sadr
FAFaezeh Atri
Faezeh Atri
Computer-aided design/computer-aided manufacturing (CAD/CAM) systems are widely used for the fabrication of porcelain-fused-to-metal (PFM) crowns. This study was conducted to compare PFM crowns through triple scanning in terms of marginal discrepancy between the CAD/CAM and lost-wax fabrication techniques. Twenty uniform resin dies of a prepared maxillary first molar were randomly divided into 2 groups: conventional lost-wax; and milling. Marginal discrepancy was evaluated at the framework and porcelain steps through triple scanning and direct visualization under a stereomicroscope. Then, the crowns were cemented to the related die and the marginal gap was measured with triple scanning, direct visualization under a stereomicroscope and scanning electron microscopy (SEM). The data was analyzed using the independent t test and the one-way analysis of variance (ANOVA). The significance level was set at 0.05. Differences in the mean marginal gap were measured by the various evaluation methods. Triple scanning and stereomicroscopy identified increasing discrepancy during the fabrication process. According to the results of the independent t test, stereomicroscopy showed no difference after cementation between the CAD/CAM and lost-wax groups (p > 0.05), triple scanning showed higher fitness in the CAD/CAM group (p < 0.05), and SEM showed better adaptation in the lost-wax group (p < 0.05); however, there was a positive correlation between the findings of stereomicroscopy and SEM (p < 0.05). The cobalt-chromium crowns had clinically acceptable marginal fitness from both the CAD/CAM and lost-wax techniques; however, the lost-wax group showed lower marginal discrepancy after cementation according to SEM.

14 December 2023 in International Journal of Dentistry
Verified
Journal Article
Open access
PDF file
KNKimia Nokar
Kimia Nokar
FAFaezeh Atri
Faezeh Atri
SNSaied Nokar
Saied Nokar
Background. Choosing implant crown materials for restoration remains challenging in clinical practice. This study assesses the impact of all-ceramic restoration instead of porcelain-fused-to-metal (PFM) restoration on the stress distribution within implant components and the surrounding bone. Methods. Four 3D models of a mandibular second premolar were meticulously prepared. The study groups comprised zirconia, lithium disilicate, and zirconia lithium silicate monolithic ceramic crowns cemented onto a zirconia hybrid abutment. A PFM crown cemented onto a cementable abutment was chosen as the control group. A total vertical load of 583N was applied to the occlusal contact areas. Stress distribution within the crown and implant components was analyzed using von Mises stress analysis. Principal stress analyses were employed to assess stress distribution in the peripheral bone. Results. The PFM model exhibited the highest von Mises stress values for both the implant (428.7MPa) and crown (79.7MPa) compared to the other models. The all-ceramic models displayed the highest maximum von Mises stress within the abutment, approximately 335MPa, compared to the PFM model. von Mises stresses of the abutment and implant in the all-ceramic models were 69 higher and 20 lower, respectively, than those in the PFM model. Screw stresses were relatively consistent across all groups. Principal stresses in spongy bone and minimum principal stress in cortical bone were consistent across all models. Conclusions. All-ceramic restoration with a hybrid abutment, as opposed to traditional PFM restoration with a cementable abutment, does not adversely affect the implant and abutment screw and reduces crown stresses. Stresses within hybrid abutments were notably higher than those within cementable abutments. Spongy bone stresses remained unaffected by the type of crown or abutment.

8 June 2023 in Clinical and Experimental Dental Research
Verified
Journal Article
Open access
NMNeshatafarin Manouchehri
Neshatafarin Manouchehri
SGSafoura Ghodsi
Safoura Ghodsi
FAFaezeh Atri
Faezeh Atri
PSPegah Sarraf
Pegah Sarraf
DSDorsa Seyedi
Dorsa Seyedi
SVSara Valizadeh
Sara Valizadeh
Introduction: Achieving stable adhesion between fiber post and interradicular dentin is a challenging process in the restoration of endodontically treated teeth. This study was conducted to investigate the effect of surface pretreatment with cold atmospheric plasma (CAP) on improving the bond strength between them.Materials and methods: Forty‐eight single‐canal mandibular premolars were cut 1 mm above the cementoenamel junction to keep the root length of 14 mm or more. After endodontic treatment and preparation of the post space, the teeth were divided into four groups regarding the pretreatment of dentin surfaces, including normal saline, ethylenediaminetetraacetic acid (EDTA), CAP, and CAP + EDTA groups. The data were analyzed using paired and independent t‐test and one‐way analysis of variance and the significance level was set at p < .05.Results: The bond strength was significantly higher in the coronal third than in the apical third in all the groups. Moreover, the bond strength was significantly higher in the CAP + EDTA‐treated group. The bond strength increased significantly in the CAP group compared to the normal saline group. In addition, the bond strength increased significantly in the CAP or EDTA groups compared to the control group. The lowest bond strength belonged to the control group (normal saline).Conclusion: The surface pretreatment with CAP (alone or in combination with EDTA) played a significant role in improving the bond strength of fiber post and root canal dentin.