9 December 2021 in IEEE Transactions on Smart Grid
Today’s power distribution system is changing to a power-electronics-enabled distribution system, especially with the increasing penetration of distributed energy resources (DERs). To monitor and manage those electronic devices and DERs at the grid edge, the advanced metering infrastructure (AMI) with two-way communications presents great potential. At present, extensive research explores the upstream communication from smart meters to electric utilities (e.g., meter reading) but few examine the downstream communication from the utilities to smart meters (e.g., meter pinging). This paper discusses the AMI two-way communication and its recent industrial practice in the U.S., especially for applying the smart meter pinging functionality to monitor grid-edge devices and DERs. This paper then develops the two-way communication model and the network calculus method to quantify the impact of the two-way communication on the AMI network. In the end, the proposed method is validated with ns-3 simulation using the modified 13-node test feeder and real-world feeder systems.
11 April 2016 in IEEE Transactions on Power Systems
This paper proposes a new approach for power system transient stability simulation, which is based on a semi-analytical solution (SAS) of power system differential-algebraic equations. In this paper, an SAS is derived using the Adomian decomposition method as a closed-form explicit function of symbolic variables such as time, the initial state, and other variables on system conditions and; hence, it can directly give a power system's dynamic trajectory being accurate for a certain time window. Unlike a traditional numerical integration based simulation approach, the proposed new approach offline derives an SAS and online evaluates the SAS by plugging in values of symbolic variables for a series of time windows making up the desired simulation period. This paper further studies the maximum length of the time window for an SAS being accurate and proposes a divergence indicator for simulation using adaptive time windows. Implementation of this new approach on parallel computers is also studied. The new approach is validated through contingency simulation of the IEEE 10-generator 39-bus system with detailed generator models.
20 September 2018 in IEEE Transactions on Power Systems
Time-domain simulation is the basis of dynamic security assessment for power systems. Traditionally, numerical integration methods are adopted by simulation software to solve nonlinear power system dynamics for any given contingency under a specific operating condition. An alternative simulation approach promising for online applications is to offline derive a semi-analytical solution (SAS) for power system differential equations and then online evaluate the SAS over consecutive time windows regarding the operating condition and contingency until the simulation result over a desired period is obtained. This paper proposes a general semi-analytical approach that derives and evaluates an SAS in the form of a power series in time to approximate the true solution. This paper provides an error-rate upper bound of the SAS for reliable use of adaptive time windows in evaluation of the SAS. To extend the semi-analytical approach for solving general power system differential-algebraic equations, this paper also proposes a dynamic bus method to efficiently link the SAS for dynamic components with the numerical solution of the network algebraic equations. Case studies on the New England 39-bus system and the Polish 2383-bus system test the performance of the proposed approach, compare it with other methods, and show the potentials of the proposed semi-analytical approach for online simulation.
4 July 2022 in IEEE Transactions on Power Systems
This paper proposes a physics-informed sparse Gaussian process (SGP) for probabilistic stability assessment of large-scale power systems in the presence of uncertain dynamic PVs and loads. The differential and algebraic equations considering uncertainties from dynamic PVs and loads are reformulated to a nonlinear mapping relationship that allows the application of SGP. Thanks to the nonparametric characteristic of Gaussian process, the proposed framework does not require distributions of uncertain inputs and this distinguishes it from existing approaches. As the original Gaussian process is not scalable to large-scale systems with high dimensional uncertain inputs, this paper develops the SGP with a stochastic variational inference technique. It leads to approximately two orders of complex reduction. A data pre-processing step is also introduced to tackle the coexistence of stable and unstable cases by sample clustering and constructing separate SGPs. The probabilistic transient stability index is analyzed to assess system stability under different uncertain dynamics loads and PVs. Comparisons are performed with the sampling-based, the polynomial chaos expansion-based, and traditional Gaussian process-based methods on the modified IEEE 118-bus and Texas 2000-bus systems under various scenarios, including different levels of uncertainties and the existence of nonlinear correlations among dynamic PVs. The impacts of data quality and quantity issues are also investigated. It is shown that the proposed SGP achieves significantly improved computational efficiency while maintaining high accuracy with a limited number of data.
25 March 2021 in IEEE Transactions on Power Systems
Global sensitivity analysis (GSA) of distribution system with respect to stochastic PV and load variations plays an important role in designing optimal voltage control schemes. This paper proposes a data-driven framework for GSA of distribution system. In particular, two representative surrogate modeling-based approaches are developed, including the traditional Gaussian process-based and the analysis of variance (ANOVA) kernel ones. The key idea is to develop a surrogate model that captures the hidden global relationship between voltage and real and reactive power injections from the historical data. With the surrogate model, the Sobol indices can be conveniently calculated through either the sampling-based method or the analytical method to assess the global sensitivity of voltage to variations of load and PV power injections. The sampling-based method estimates the Sobol indices using Monte Carlo simulations while the analytical method calculates them by resorting to the ANOVA expansion framework. Comparison results with other model-based GSA methods on the unbalanced three-phase IEEE 37-bus and 123-bus distribution systems show that the proposed framework can achieve much higher computational efficiency with negligible loss of accuracy. The results on a real 240-bus distribution system using actual smart meter data further validate the feasibility and scalability of the proposed framework.
17 January 2020 in IEEE Transactions on Smart Grid
Frequency is an important metric for power stability. To enhance the situational awareness in power distribution systems, this paper proposes a data-driven approach that utilizes the data from micro phasor measurement units (μPMU) to categorize frequency events observed in distribution feeders. The proposed approach has three layers, each of which analyzes if a frequency event is propagated from the transmission system, formed inside a distribution feeder or falsely produced by instantaneous frequency (IF) estimation algorithms, respectively. In the first layer, the Granger causality is utilized to compare the causal relations from measurements across different locations to decide if an event is propagated from the transmission side. In the second layer, a trained sparse coding dictionary is utilized to unmix the physical causes of a frequency event. In the third layer, a moving z-score based event-pair detector is applied to identify if a frequency event is algorithm-induced. The proposed approach is tested using the μPMU measurements collected from Lawrence Berkeley National Laboratory (LBNL) and Riverside Public Utility (RPU).