Nathaniel L. Elsen

Nathaniel L. Elsen

Auto-generated profile, based on publicly available information

Nathaniel L. Elsen

AbbVie (United States) 2 , North Chicago, Illinois

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2020 in ACS Medicinal Chemistry Letters
Verified
Journal Article
Closed access
FPFan Pu
Fan Pu
NENathaniel L. Elsen
Nathaniel L. Elsen
JWJon D. Williams
Jon D. Williams

29 September 2022 in Journal of the American Society for Mass Spectrometry
Verified
Journal Article
Closed access
KKKevan T. Knizner
Kevan T. Knizner
JGJacob P. Guymon
Jacob P. Guymon
KGKenneth P. Garrard
Kenneth P. Garrard
GBGuy Bouvrée
Guy Bouvrée
JMJeffrey Manni
Jeffrey Manni
DMDavid Chalres Muddiman
David Chalres Muddiman

15 March 2022 in Analytical Chemistry
Verified
Journal Article
Closed access
ARAndrew J. Radosevich
Andrew J. Radosevich
FPFan Pu
Fan Pu
DCDavid Chang-Yen
David Chang-Yen
JSJames W. Sawicki
James W. Sawicki
NTNari N. Talaty
Nari N. Talaty
JPJeffrey Y. Pan
Jeffrey Y. Pan

22 April 2021 in Analytical Chemistry
Verified
Journal Article
Closed access
FPFan Pu
Fan Pu
ARAndrew J. Radosevich
Andrew J. Radosevich
JSJames W. Sawicki
James W. Sawicki
DCDavid Chang-Yen
David Chang-Yen
NTNari N. Talaty
Nari N. Talaty
NENathaniel L. Elsen
Nathaniel L. Elsen

21 September 2022 in Analytical Chemistry
Verified
Journal Article
Open access
FPFan Pu
Fan Pu
SUScott A. Ugrin
Scott A. Ugrin
ARAndrew J. Radosevich
Andrew J. Radosevich
DCDavid Chang-Yen
David Chang-Yen
JSJames W. Sawicki
James W. Sawicki
JWJon D. Williams
Jon D. Williams
Mass spectrometry (MS) is the primary analytical tool used to characterize proteins within the biopharmaceutical industry. Electrospray ionization (ESI) coupled to liquid chromatography (LC) is the current gold standard for intact protein analysis. However, inherent speed limitations of LC/MS prevent analysis of large sample numbers (>1000) in a day. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI-MS), an ambient ionization MS technology, has recently been established as a platform for high-throughput small molecule analysis. Here, we report the applications of such a system for the analysis of intact proteins commonly performed within the drug discovery process. A wide molecular weight range of proteins 10-150 kDa was detected on the system with improved tolerance to salts and buffers compared to ESI. With high concentrations and model proteins, a sample rate of up to 22 Hz was obtained. For proteins at low concentrations and in buffers used in commonly employed assays, robust data at a sample rate of 1.5 Hz were achieved, which is ∼22× faster than current technologies used for high-throughput ESI-MS-based protein assays. In addition, two multiplexed plate-based high-throughput sample cleanup methods were coupled to IR-MALDESI-MS to enable analysis of samples containing excessive amounts of salts and buffers without fully compromising productivity. Example experiments, which leverage the speed of the IR-MALDESI-MS system to monitor NISTmAb reduction, protein autophosphorylation, and compound binding kinetics in near real time, are demonstrated.

24 January 2022 in Journal of the American Society for Mass Spectrometry
Verified
Journal Article
Closed access
KKKevan T. Knizner
Kevan T. Knizner
MBMichael C. Bagley
Michael C. Bagley
KGKenneth P. Garrard
Kenneth P. Garrard
JHJan-Peter Hauschild
Jan-Peter Hauschild
FPFan Pu
Fan Pu
DMDavid Chalres Muddiman
David Chalres Muddiman