Jeanette Ivonne Borja Arroyo

Dr. Jeanette Ivonne Borja Arroyo

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2024 in Revista de la Facultad de Medicina Humana
Verified
Journal Article
Open access
PDF file
CCCesar Martel Cervantes
Cesar Martel Cervantes
U(Universidad Ricardo Palma Grupo de Investigación En Robótica Y Mecatrónica Avanzada (Gi-Roma)
Universidad Ricardo Palma Grupo de Investigación En Robótica Y Mecatrónica Avanzada (Gi-Roma)
CSCarol Sandoval
Carol Sandoval
RPRicardo Palomares
Ricardo Palomares
JAJeanette Ivonne Borja Arroyo
Jeanette Ivonne Borja Arroyo
Jose Cornejo, Ph.D.Jose Cornejo, Ph.D.
Jose Cornejo, Ph.D.
Background: Cerebrovascular accident (CVA) is one of the main causes of permanent disability, as it can cause serious brain injuries with significant physical consequences, limiting the ability to perform daily activities. Objective: This research aimed to design a robotic system of passive-continuous movement for the rehabilitation of lower limbs in adult patients with stroke, thus improving the chances of recovery of their walking mobility. Methodology: Modeling and simulation of the robotic system using Computer Aided Design (CAD), using the engineering software Autodesk Inventor Professional 2023. Results: The initial and final positions of the robotic system were obtained, as well as the simulation of passive-continuous movement. Conclusions: Taking precise measurements of a patient maximizes the possibility of implementing a functional prototype that contributes to the rehabilitation process. Antecedentes: El accidente cerebrovascular (ACV) es una de las principales causas de discapacidad permanente, ya que puede provocar lesiones cerebrales graves con secuelas físicas significativas, limitando la capacidad de realizar actividades diarias. Objetivo: Esta investigación tuvo como objetivo diseñar un sistema robótico de movimiento pasivo-continuo para la rehabilitación de miembros inferiores en pacientes adultos con ACV, mejorando así las probabilidades de recuperación de su movilidad de marcha. Metodología: Se llevó a cabo el modelado y simulación del sistema robótico mediante Diseño Asistido por Computadora (CAD), utilizando el software de ingeniería Autodesk Inventor Professional 2023. Resultados: Se obtuvieron las posiciones iniciales y finales del sistema robótico, así como la simulación de movimiento pasivo-continuo. Conclusiones: La toma de medidas precisas de un paciente maximiza la posibilidad de implementar un prototipo funcional que contribuya en el proceso de rehabilitación.

29 December 2025 in Revista de la Facultad de Medicina Humana
Verified
Journal Article
Closed access
Adrian Mijail NacarinoAdrian Mijail Nacarino
Adrian Mijail Nacarino
JAJeanette Ivonne Borja Arroyo
Jeanette Ivonne Borja Arroyo
CSCarol Sandoval
Carol Sandoval
CMCesar Martel
Cesar Martel
Jose Cornejo, Ph.D.Jose Cornejo, Ph.D.
Jose Cornejo, Ph.D.
RPRicardo Palomares
Ricardo Palomares
Stroke is the second leading cause of death and the third leading cause of disability worldwide, with an incidence increase of over 70% between 1990 and 2019. Robotic rehabilitation systems for the lower limbs have emerged as promising alternatives to conventional therapy for post-stroke patients. This work presents a review of current mechatronic technologies applied to lower-limb rehabilitation robotics, based on peer-reviewed scientific literature and patent developments from the past decade. The review was conducted using the Scopus, ScienceDirect, and IEEE Xplore databases, supplemented by patents from WIPO, Espacenet, and ASEAN IP. Rehabilitation methods, control strategies, and clinical outcomes of robotic systems were analyzed. The findings show that, when used alongside conventional therapy, these systems yield significant improvements in motor function, gait capacity, muscle strength, and balance. The patent analysis reveals diverse technological approaches, such as the integration of cryotherapy, multimodal control systems, and bilateral coupling strategies. However, heterogeneity in performance metrics and experimental designs limits rigorous comparisons across strategies. Based on these findings, a lower-limb rehabilitation exoskeleton is proposed, featuring three operating modes: knee, ankle, and combined. A neural network-based control system using EMG (Electromyography) signals is employed to recognize movement intention. This technology could significantly benefit developing countries like Peru by strengthening post-stroke rehabilitation services.

16 November 2026 in Technologies
Verified
Journal Article
Open access
PDF file
Adrian Mijail NacarinoAdrian Mijail Nacarino
Adrian Mijail Nacarino
HPHarnnol Suclupe Panduro
Harnnol Suclupe Panduro
CSCarol Sandoval
Carol Sandoval
CMCesar Martel
Cesar Martel
Jose Cornejo, Ph.D.Jose Cornejo, Ph.D.
Jose Cornejo, Ph.D.
RPRicardo Palomares
Ricardo Palomares
This study developed and preliminarily validated a robotic Continuous Passive Motion (CPM) system intended for lower-limb rehabilitation in post-stroke adult patients with hemiplegia. Building upon a previous redesign and simulation stage using a virtual patient model, an adjustable structure made of AISI 316L stainless steel was fabricated, integrating the mechanical, electronic, and control subsystems for passive knee and ankle mobilization through a lead screw mechanism driven by a NEMA23 stepper motor, a TB6600 driver, and an ESP32 microcontroller operating under an open-loop feedforward control scheme. As a preliminary stage prior to clinical evaluation, functional validation was conducted through three knee therapy tests, two with a healthy adult volunteer and one under unloaded conditions, using different angular ranges (90–130°, 30–26°, and 50–70°). The device successfully executed the programmed movements without mechanical or electronic failures, completing all three repetitions in each session and recording observed differences ranging from 2.00% to 11.54% between the programmed and measured joint angles. These results demonstrate the preliminary technical feasibility of the proposed prototype. The present validation was limited to a single adult volunteer and three knee-motion tests. Future work will include validation with volunteers representing different anthropometric profiles (1.55–1.75 m), verification of emergency stop response times below 100 ms, and the incorporation of encoder-based position feedback as preliminary steps toward subsequent clinical evaluation.