Adrian Mijail Nacarino

Mr. Adrian Mijail Nacarino

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

31 October 2024 in Revista de la Facultad de Medicina Humana
Verified
Journal Article
Open access
PDF file
Adrian Mijail NacarinoAdrian Mijail Nacarino
Adrian Mijail Nacarino
ALAnderson La-Rosa
Anderson La-Rosa
BSBryan Sanchez
Bryan Sanchez
JCJose Cornejo
Jose Cornejo
MVMariela Vargas
Mariela Vargas
RPRicardo Palomares
Ricardo Palomares
La realidad mixta (RM) se sitúa entre la realidad aumentada (RA) y la realidad virtual (RV), combinando elementos de ambas para ofrecer una experiencia interactiva más avanzada. La RV crea entornos completamente virtuales e inmersivos que pueden involucrar múltiples sentidos, mientras que la RA superpone datos virtuales sobre el entorno real, sin una interacción profunda (1). En contraste, la RM integra datos virtuales en el entorno real de manera que estos interactúan en tiempo real, proporcionando una experiencia más inmersiva y funcional (2,3).

29 May 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
Adrian Mijail NacarinoAdrian Mijail Nacarino
Adrian Mijail Nacarino
BSBryan Sanchez
Bryan Sanchez
SCSandra Charapaqui
Sandra Charapaqui
RCRenzo Charapaqui
Renzo Charapaqui
RMRenzo R. Maldonado-Gómez
Renzo R. Maldonado-Gómez
JCJorge Cornejo
Jorge Cornejo
Stroke is the second leading cause of death globally and a major contributor to lower-limb disability, affecting gait, balance, and functional independence in elderly populations. While robot-assisted rehabilitation has demonstrated effectiveness in motor recovery, access remains limited due to high costs and geographic barriers, particularly in Latin America. This study presents ExoKnee, a low-cost knee exoskeleton designed through biomimetic principles and 3D-printed fabrication as a proof-of-concept device targeting gait rehabilitation in elderly adults. The system integrates a single-degree-of-freedom pneumatic actuator controlled by electromyography (EMG) signals from the quadriceps muscle, enabling knee flexion and extension (90° to 180°). The design was evaluated through finite element analysis and dynamic simulations in MATLAB/Simulink R2024a under constant, stepwise, and sinusoidal reference inputs in a digital-twin environment. Expert validation using the Content Validity Coefficient yielded a mean score of 0.8747, reflecting preliminary expert agreement on the conceptual design’s coherence and relevance. The prototype demonstrated controlled movements through a 6-bar pneumatic system with EMG-triggered relay activation, validated at the proof-of-concept level through simulation and single-subject threshold calibration. ExoKnee addresses critical gaps by offering an anthropometrically informed, biosignal-driven, and locally manufacturable rehabilitation platform for low- and middle-income countries, pending clinical validation. Future work will focus on clinical trials and adaptive EMG control strategies.

7 November 2024
Verified
Conference Paper
Closed access
Adrian Mijail NacarinoAdrian Mijail Nacarino
Adrian Mijail Nacarino
ARAndre Rueda-Lopez
Andre Rueda-Lopez
JQJoel Quispe-Castro
Joel Quispe-Castro
BVBryan P. Vega-Samanez
Bryan P. Vega-Samanez
Jose Cornejo, Ph.D.Jose Cornejo, Ph.D.
Jose Cornejo, Ph.D.
One of the most common failures in computer hardware is the slowness and lack of computing power due to dust accumulation in the fan, reducing its risk. In the face of this problem, vibrational analysis, as an area of predictive maintenance, represents a tool that is beneficial in predicting when equipment is going to fail and carrying out repair work based on it. This is why innovative research has been proposed under the supervision of the School of Engineering Mechatronics at Ricardo Palma University of a mechatronics system for the predictive maintenance industry. The mechanical design consisted of a case to support the motor fan for an isolated test, the electrical design consisted of a Hall effect sensor to detect the RPM variation in a certain period, as well as, a temperature sensor in the center and one corner to compare the variations between these points. In the electronic design, the Arduino UNO controller is selected based on the system operating voltage of 5 V to supply the complete system. The MATLAB interface displayed the results of the frequency spectrum compared to the regular operation of a good-condition fan, and simultaneously showed the variations in RPM and temperature conditions, in conclusion, favorable results were achieved. For future research, it is proposed to use a MAT LAB app to automatically incorporate all of this data while capturing the sound directly through a mobile phone and including a thermal camera to visualize the temperature distribution in the engine.

9 October 2025
Verified
Conference Paper
Closed access
Adrian Mijail NacarinoAdrian Mijail Nacarino
Adrian Mijail Nacarino
BSBryan Sanchez
Bryan Sanchez
RPRicardo Palomares
Ricardo Palomares
FVFreedy Sotelo Valer
Freedy Sotelo Valer
Jose Cornejo, Ph.D.Jose Cornejo, Ph.D.
Jose Cornejo, Ph.D.
MVMariela Vargas
Mariela Vargas
This paper presents ExoKnee, a pneumatic knee exoskeleton to provide mobility support for elderly adults. The system was designed using standardized anthropometric measurements (ISO 7250-1:2017) to ensure proper ergonomic fit. The device integrated a pneumatic actuator (FESTO DSNU-S-12-50-P-A-MQ); with a control system based on electromyography (EMG) signals, which allowed the execution of flexion and extension movements; subsequently, a biomechanical model was developed in OpenSim from which realistic joint kinematics data were extracted, which guided dynamic simulations in MATLAB/Simulink. The mechanical structure was validated through Computer-Aided Design (CAD) and the kinematic behavior was evaluated in CoppeliaSim, simulating a rehabilitation environment with a virtual patient performing repetitive exercises. Finally, a functional prototype was manufactured through 3D printing; which achieved a range of motion from 109° to 175°, with an absolute error of 8.16%; altogether, ExoKnee stands out for its accessible, modular, and anthropometrically adapted design; therefore, it is proposed as an inclusive technology for walking support in elderly adults.

29 December 2025 in Revista de la Facultad de Medicina Humana
Verified
Journal Article
Closed access
Adrian Mijail NacarinoAdrian Mijail Nacarino
Adrian Mijail Nacarino
JBJeanette Borja
Jeanette Borja
CSCarol Sandoval
Carol Sandoval
CMCesar Martel
Cesar Martel
Jose Cornejo, Ph.D.Jose Cornejo, Ph.D.
Jose Cornejo, Ph.D.
RPRicardo Palomares
Ricardo Palomares
Stroke is the second leading cause of death and the third leading cause of disability worldwide, with an incidence increase of over 70% between 1990 and 2019. Robotic rehabilitation systems for the lower limbs have emerged as promising alternatives to conventional therapy for post-stroke patients. This work presents a review of current mechatronic technologies applied to lower-limb rehabilitation robotics, based on peer-reviewed scientific literature and patent developments from the past decade. The review was conducted using the Scopus, ScienceDirect, and IEEE Xplore databases, supplemented by patents from WIPO, Espacenet, and ASEAN IP. Rehabilitation methods, control strategies, and clinical outcomes of robotic systems were analyzed. The findings show that, when used alongside conventional therapy, these systems yield significant improvements in motor function, gait capacity, muscle strength, and balance. The patent analysis reveals diverse technological approaches, such as the integration of cryotherapy, multimodal control systems, and bilateral coupling strategies. However, heterogeneity in performance metrics and experimental designs limits rigorous comparisons across strategies. Based on these findings, a lower-limb rehabilitation exoskeleton is proposed, featuring three operating modes: knee, ankle, and combined. A neural network-based control system using EMG (Electromyography) signals is employed to recognize movement intention. This technology could significantly benefit developing countries like Peru by strengthening post-stroke rehabilitation services.