Yidi Shen

Yidi Shen

Auto-generated profile, based on publicly available information

Yidi Shen

Department of Electrical and Computer Engineering, Maryland Power Electronics Laboratory, Institute for Systems Research, University of Maryland, College Park, MD, USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YSYidi Shen
Yidi Shen
MDMichael D'ANtonio
Michael D'ANtonio
SCShiladri Chakraborty
Shiladri Chakraborty
AHArafat Hasnain
Arafat Hasnain
AKAlireza Khaligh
Alireza Khaligh
Single-phase inverter or rectifier systems often make use of an active power decoupler (APD) to balance the mismatch between constant dc power and fluctuating ac power. This article deals with the comparison of continuous conduction mode (CCM) and critical conduction mode (CRM) operation-based design of a parallel boost-type APD for photovoltaic microinverter applications. From a design perspective, multiobjective analysis of efficiency, volume, and cost is explored within a decision space including planar inductors, gallium nitride based devices, film capacitors, switching frequency, and modulation (CCM vs. CRM). The theoretical study analyzes all possible design configurations within CCM and CRM and identifies Pareto-optimal designs, from which the selected CRM design can achieve reduced system volume and lower cost with the use of smaller inductor core, while operating with similar California Energy Commission efficiency drop as the selected CCM design. From a control perspective, a pulsewidth modulation based control strategy is proposed to implement closed-loop CRM modulation that does not rely on zero-crossing detection. Closed-loop systems are designed for the optimal CCM and CRM realizations, and the final system characteristics are compared. Experimental results, obtained using two separate 40-V, 400-W hardware prototypes for CCM and CRM, are presented to verify the analyses.

29 October 2023
Verified
Conference Paper
Open access
RGReza Asrar Ghaderloo
Reza Asrar Ghaderloo
YSYidi Shen
Yidi Shen
CSChanaka Singhabahu
Chanaka Singhabahu
RRRakesh Resalayyan
Rakesh Resalayyan
AKAlireza Khaligh
Alireza Khaligh
Bus-clamping Pulse Width Modulation (PWM) is an effective method to reduce the switching loss in a three-phase voltage source inverter (VSI). In bus-clamping PWM scheme, the phase legs are switched using high frequency PWM signals for two-third of the line cycle, while for the remaining duration of cycle, the pole voltage is clamped to either positive or negative rail of the DC bus. In PWM operation of a half bridge, a dead-time is applied between the gate signals of complementary switches to ensure safe and reliable operation. However, introduction of dead-time leads to poor power quality, increased Total Harmonic Distortion (THD) and variation in actual voltage compared to the intended pole voltage. Moreover, when the bus-clamping technique is used, the PWM has both high frequency switching region and clamped region in a line cycle, and consequently, the undesired effects of dead-time are further aggravated. Therefore, in order to enhance the quality of output voltage, this paper presents a dead-time compensation strategy for a VSI operating with bus-clamping PWM. The proposed method calculates the required compensation term to be added on the modulation signal considering wide range of operating conditions. Additionally, the compensation includes a new strategy for low current conditions near zero-crossing to avoid distortion. The proposed method is verified by simulation and experiments in a three-phase VSI with a switching frequency of 100 kHz and a fundamental frequency of 60Hz.

17 August 2023 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YSYidi Shen
Yidi Shen
DZDaniel Zakzewski
Daniel Zakzewski
AHArafat Hasnain
Arafat Hasnain
RRRakesh Resalayyan
Rakesh Resalayyan
AKAlireza Khaligh
Alireza Khaligh
Active power decoupling (APD) is a highly adopted technique for compact and reliable single-phase inverters to eliminate the undesired ac power drawn from the dc port. Typical operation of APD circuits requires the use of additional sensors measuring APD states to ensure proper decoupling. The additional voltage and current sensors add to system cost and hardware design complexity. This paper proposes a sensorless control approach that provides proper control of the APD without the use of additional sensors. The proposed predictive power decoupling control is analyzed together with the operating principle of the APD, and two types of error correctors are introduced to improve the control accuracy and reduce the reliance on the circuit component parameters. The proposed approach provides equally good power decoupling performance compared to traditional sensor-based control strategies while improving the dynamic response. The proposed approach is experimentally verified using a 30 - 60 V parallel APD circuit and 200 W microinverter hardware prototype.

20 May 2025 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
RGReza Asrar Ghaderloo
Reza Asrar Ghaderloo
YSYidi Shen
Yidi Shen
HCHassan Habib Chaudhry
Hassan Habib Chaudhry
CSChanaka Singhabahu
Chanaka Singhabahu
AKAlireza Khaligh
Alireza Khaligh
The three-level T-type (3LTT) inverter incorporates two cascaded dc-link capacitors that share a common coupling node (CCN) known as neutral point. During the operation of T-type inverter, the CCN voltage oscillates at triple the line frequency. Furthermore, in some applications such as dual-input photovoltaic systems, there may be a dc voltage imbalance across dc-link capacitors, resulting in an unbalanced CCN voltage. The presence of an unbalanced or oscillating CCN voltage in T-type inverter affects the quality of output current and voltage waveform by introducing low-frequency harmonics. To address this issue, this article proposes a novel modulation method to compensate the effects of unbalanced and oscillating CCN voltage, enabling the generation of nondistorted phase voltage and current. By enhancing the output waveforms quality, the proposed method can result in reduction of the dc-link capacitor size and improvement of power density in the T-type inverter. In this method, the modulation signal is adjusted using simple mathematical calculations based on the sensed CCN and dc-link voltage, which imposes negligible processing time on the microcontroller. This method is applicable across the entire range of operation, regardless of load power factor or modulation index. Furthermore, the proposed method preserves the high-quality and sinusoidal shape of output current waveform even under dynamic disturbances in the CCN and dc-link voltage. To provide further insight, the normalized increase in total semiconductor loss due to the implementation of the proposed method is also evaluated. Finally, the analytical and experimental results are conducted to validate the effectiveness of the proposed compensating method.

5 April 2024 in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
Verified
Journal Article
Closed access
DZDaniel Zakzewski
Daniel Zakzewski
YSYidi Shen
Yidi Shen
AHArafat Hasnain
Arafat Hasnain
RRRakesh Resalayyan
Rakesh Resalayyan
AKAlireza Khaligh
Alireza Khaligh
Dielectrics used in class II multi-layer ceramic capacitors offer vastly higher dielectric constants than class I ceramics or film capacitors, leading to large volumetric and cost savings. However, class II ceramic capacitors undesirably tend to have varying capacitance depending on the voltage applied across it, referred to as voltage characteristic of capacitance (VCC). When class II ceramic capacitors are connected to an ac-source, VCC can contribute large harmonic content, adversely impacting power quality. If left unmitigated, additional filtering may be required to meet electromagnetic compatibility (EMC) standards, thus reducing volumetric benefits of class II ceramic capacitors. Furthermore, control systems relying on accurate feedforward require predictive control of such effects. This work introduces a compensation strategy to mitigate current distortions induced by VCC, leading to an enhancement in converter power quality without the need for additional filtering. To achieve satisfactory mitigation with minimal control burden, the paper also proposes a mathematical model describing the voltage characteristic. A design application is used to demonstrate the relevant trade-offs and the effectiveness of the proposed compensation approaches in enhancing power quality performance is validated through experimental testing.

18 April 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YSYidi Shen
Yidi Shen
AHArafat Hasnain
Arafat Hasnain
DZDaniel Zakzewski
Daniel Zakzewski
RRRakesh Resalayyan
Rakesh Resalayyan
AKAlireza Khaligh
Alireza Khaligh
In single-phase power conversion systems, there is an inherent difference between the dc-side constant and ac-side oscillating power, and power decoupling is required especially in applications like photovoltaic (PV) inverters. Active power decoupling (APD) converters are often used to balance instantaneous power while reducing the size of dc link capacitors and improving the system reliability. Conventionally, APD converters are controlled to decouple only sinusoidal power at double-line frequency. However, the control is further complicated when nonsinusoidal power is delivered due to nonlinear circuit components, nonlinear loads, or grid distortions. This article proposes an improved feedforward APD control scheme with the capability of decoupling nonsinusoidal power, which has application in single-phase systems, particularly all types of PV microinverters. The proposed feedforward control includes the capacitor voltage calculation under arbitrary power harmonics and a dead-time compensation to increase the accuracy of duty prediction. The proposed algorithm can work as open-loop control to eliminate APD sensors and can serve as a feedforward term in closed-loop control to improve power decoupling performance, thereby simplifying the controller design. The proposed approach is experimentally verified using a dc-parallel APD prototype, a 50 V 250 W microinverter with nonlinear ac capacitor, and a diode rectifier load.