Chuntian Lu

Chuntian Lu

Auto-generated profile, based on publicly available information

Chuntian Lu

Hebei Branch of China Nuclear Power Engineering Company, Shijiazhuang 050011, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 March 2024 in Energies
Verified
Journal Article
Open access
PDF file
CLChuntian Lu
Chuntian Lu
JYJianjun YANG
Jianjun YANG
QZQiang Zhang
Qiang Zhang
The transient characteristics of pressure in the condenser under fault conditions have a crucial impact on the safe operation of the entire nuclear power plant. In order to ascertain whether the condenser pressure of a HPR1000 nuclear power unit meets the requirements of the steam generator, this paper establishes a mathematical model of the condenser, along with the connected steam turbine bypass steam system and circulating water system, based on Apros. The accuracy of the simulation model is verified by comparing the coasting curve of the circulating water pump with the flow change curve under the pump-tripping condition in Apros. Under the initial CCR condition and the half-side operating condition of the condenser, simulation analyses were conducted for two transient sequences involving the loss of normal external power and the simultaneous tripping of two circulating water pumps. The corresponding changes of pressure in the condenser under the transient sequence were obtained. The study reveals that, under different initial conditions and transient sequences, the condenser pressure of the unit can meet the requirements of a 12 s steam discharge to the condenser before the internal pressure of the condenser reaches the “unavailable” set value when the turbine bypass system is under the fault condition. The research findings of this paper can provide reference data for the design, commissioning, and operation of subsequent HPR1000 nuclear power plants.

16 January 2025 in Materials
Verified
Journal Article
Open access
PDF file
MZMengxi Zhang
Mengxi Zhang
CLChuntian Lu
Chuntian Lu
QMQiaoling Min
Qiaoling Min
Xinyue WangXinyue Wang
Xinyue Wang
YHYinpeng P.A. He
Yinpeng P.A. He
YWYixin Wang
Yixin Wang
In this paper, the early drying shrinkage coefficients of different hydraulic cement mortars are calibrated through laboratory experiments for moderate-heat Portland cement (MHPC) and low-heat Portland cement (LHPC). By developing an improved mesoscale modeling approach, a 3D highly detailed simulation of concrete was generated, which incorporates the phases of mortar, aggregates, and interfacial transition zone (ITZ). The simulation result is in good agreement with the concrete early drying shrinkage experiment, exhibiting an error of less than 4.99% after 28 days. Subsequently, the mesoscale model is employed to explain the influence of the ambient humidity, cement type, and aggregate volume ratio on the early drying shrinkage performance of concrete. The results show that the early drying shrinkage coefficient of the LHPC is approximately 82% of the MHPC. Additionally, the depth of ambient humidity influence is about 15 mm from the concrete surface after 28 days. The early drying shrinkage can be controlled by increasing ambient humidity via the LHPC or raising the aggregate volume ratio. The mass-loss rate of concrete decreases as the ambient humidity or aggregate volume ratio increases during the process of drying shrinkage. Furthermore, the results quantify the influence patterns of various factors on drying shrinkage, thereby facilitating their application in assessing the cracking time induced by early drying shrinkage in roller-compacted concrete (RCC) dams. This provides theoretical guidance for crack prevention in concrete structures and aids in developing strategies for the construction of crack-free dams.

10 March 2025 in Buildings
Verified
Journal Article
Open access
PDF file
CLChuntian Lu
Chuntian Lu
SXShourui Xue
Shourui Xue
YZYuetong Zhang
Yuetong Zhang
SWSongqing Wang
Songqing Wang
This study addresses the optimization of heating systems for university building clusters in severe cold regions, focusing on their functional complexity, temporal usage patterns, and spatial heterogeneity. The actual university heating project in Harbin was chosen as a case study, breaking through the limitations of previous studies focusing on residential or commercial buildings. The research systematically investigates heating load variations during operational periods. It proposes three regulation strategies: constant supply water temperature with constant temperature difference regulation, variable supply water temperature with constant temperature difference regulation, and variable supply water temperature with constant temperature difference regulation combined with time-division and zone-based heating for partial buildings. The energy-saving potential of the three schemes is analyzed in depth by comparison. The results demonstrate that, compared to the constant temperature water supply and constant temperature difference regulation scheme, the other two schemes achieved energy-saving rates of 17.1% and 34.8%, respectively. In the time dimension, these schemes match the time period of energy use in universities, and in the spatial dimension, they can realize the differentiated heat supply in the functional zoning of the building clusters. This study provides a reference for optimizing the regulation of heating systems in severe cold areas.