Hui Wang

Hui Wang

Auto-generated profile, based on publicly available information

Hui Wang

Ultrasound Department of the First Affiliated Hospital of Dalian Medical University, Dalian City, China

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2018 in American Journal of Roentgenology
Verified
Journal Article
Closed access
CMCara Morin
Cara Morin
JDJonathan R Dillman
Jonathan R Dillman
SSSuraj Dilip Serai
Suraj Dilip Serai
ATAndrew T. Trout
Andrew T. Trout
JTJean A. Tkach
Jean A. Tkach
HWHui Wang
Hui Wang
The objective of our study was to compare standard breath-held, free-breathing, and compressed sensing (CS) accelerated 2D gradient-recalled echo (GRE) MR elastography (MRE) techniques for measuring liver stiffness. Twenty-five adult volunteers (20 without liver disease and five with liver disease) underwent MRE with five different 2D GRE techniques: breath-held; free-breathing; and CS with acceleration factors of 1.5, 2, and 3. Four axial images were obtained through the mid liver with each technique, and liver stiffness measurements (in kilopascals) were made by three blinded readers using elastograms with 95% confidence maps. Liver stiffness measurements were compared between techniques using repeated-measures ANOVA. Absolute agreement between techniques was evaluated for each reader using single-measure intraclass correlation coefficients (ICCs). Bland-Altman analyses were performed to assess bias between techniques using breath-held MRE as the reference. Individual subject mean liver stiffness values ranged from 1.35 to 5.25 kPa for the population. There was no significant difference in mean liver stiffness values between MRE techniques for readers 1 and 3 (p > 0.05). A significant difference (p = 0.02) due to higher stiffness measurements using free-breathing MRE was observed for reader 2. There was excellent absolute agreement between MRE techniques for each reader (all ICCs > 0.940). Bias between techniques ranged from -0.102 to 0.089 kPa for reader 1, -0.119 to 0.121 kPa for reader 2, and -0.074 to 0.085 kPa for reader 3. Free-breathing and CS accelerated 2D GRE MRE techniques yield similar results to the conventional breath-held technique with only slight bias and may be useful in pediatric and adult patients with limited ability to breath-hold.

19 July 2022 in Journal of Ultrasound in Medicine
Verified
Journal Article
Open access
YZYunpei Zhu
Yunpei Zhu
YDYanping Dou
Yanping Dou
LQLing Qin
Ling Qin
HWHui Wang
Hui Wang
ZWZhihong Wen
Zhihong Wen
Purpose: The objective of this research was to develop and validate an ultrasound‐based radiomics nomogram for the pre‐operative assessment of Ki‐67 in breast cancer (BC).Materials and Methods: From December 2016 to December 2018, 515 patients with invasive ductal breast cancer who received two‐dimensional (2D) ultrasound and Ki‐67 examination were studied and analyzed retrospectively. The dataset was distributed at random into a training cohort (n = 360) and a test cohort (n = 155) in the ratio of 7:3. Each tumor region of interest was defined based on 2D ultrasound images and radiomics features were extracted. ANOVA, maximum correlation minimum redundancy (mRMR) algorithm, and minimum absolute shrinkage and selection operator (LASSO) were performed to pick features, and independent clinical predictors were integrated with radscore to construct the nomogram for predicting Ki‐67 index by univariate and multivariate logistic regression analysis. The performance and utility of the models were evaluated by plotting receiver operating characteristic (ROC) curves, decision curve analysis (DCA), and calibration curves.Results: In the testing cohort, the area under the receiver characteristic curve (AUC) of the nomogram was 0.770 (95% confidence interval, 0.690–0.860). In both cohorts, the nomogram outperformed both the clinical model and the radiomics model (P < .05 according to the DeLong test). The analysis of DCA proved that the model has clinical utility.Conclusions: The nomogram based on 2D ultrasound images offered an approach for predicting Ki‐67 in BC.

30 October 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YCYan Cui
Yan Cui
HWHui Wang
Hui Wang
YWYuting Wang
Yuting Wang
Benign prostatic hyperplasia (BPH) is a condition commonly observed in aging males. Inflammatory and metabolic factors are pivotal in the development and progression of BPH. The degree to which the effects of 91 inflammation-related proteins on BPH are mediated by 1400 plasma metabolites remains ambiguous. Our research analyzed the impact of these traits utilizing genetic evidence.Two-sample Mendelian randomization (MR) and multivariable MR (MVMR) were utilized in our study to infer the genetic causal effect of inflammation-related proteins on BPH, with metabolites serving as mediators. Increased levels of IL-2 were linked to a heightened incidence of BPH (β = 0.071, OR:1.074, 95% CI [1.002–1.152], p = 0.045), whereas lower concentrations of N6,N6-dimethyllysine were associated with decreased risk (β1=-0.127, p = 0.02; β2=-0.039, p = 0.008). The mediation effect was 0.005 (95% CI [0.0004, 0.012], OR: 1.005, 95% CI [1.000, 1.012]), accounting for 7.04% of the total effect. subsequently, we examined the phenotypic co-localization of the two pairings independently, revealing that the posterior probability of rs145516501 associated with IL-2 and BPH was 80.7%, whereas the posterior likelihood of rs4917820 linked to N6,N6-dimethyllysine levels and BPH was 95.9%. The research indicated that N6,N6-dimethyllysine levels seem to influence the causative relationship between IL-2 and BPH. These results elucidate the complex interplay between inflammation-related proteins and metabolism in the context of BPH, offering novel diagnostic and therapeutic avenues and enhancing our comprehension of the disease’s etiology for prospective research.

2 February 2021 in Skeletal Radiology
Verified
Journal Article
Closed access
PDF file
YDYanping Dou
Yanping Dou
JXJianyuan Xuan
Jianyuan Xuan
TZTengfei Zhao
Tengfei Zhao
Xiangwen LiXiangwen Li
Xiangwen Li
HWHui Wang
Hui Wang
SWShaowu Wang
Shaowu Wang

24 November 2021 in Medicine
Verified
Journal Article
Open access
ZJZhaohua Jia
Zhaohua Jia
MQMeijing Qu
Meijing Qu
LSLipeng Sun
Lipeng Sun
HWHui Wang
Hui Wang
Background: Studies have shown inconsistent results regarding the diagnostic performance of quantitative and qualitative elastography for the differentiation of benign and malignant cervical lymph nodes. This meta-analysis aimed to estimate the diagnostic performance of ultrasound elastography in patients with cervical lymphadenopathy. Methods: We will search PubMed, Web of Science, Cochrane Library, and Chinese biomedical databases from their inceptions to the May 30, 2021, without language restrictions. Two authors will independently carry out searching literature records, scanning titles and abstracts, full texts, collecting data, and assessing risk of bias. Review Manager 5.2 and Stata14.0 software will be used for data analysis. Results: This systematic review will determine the accuracy of shear wave elastography and strain elastography in the differential diagnosis between benign and malignant cervical lymph nodes. Conclusion: Its findings will provide helpful evidence for the accuracy of shear wave elastography and strain elastography in the differential diagnosis between benign and malignant cervical lymph nodes. Systematic review registration: INPLASY202150109.

22 January 2021 in Medicine
Verified
Journal Article
Open access
PSPing Sui
Ping Sui
XWXiaoyan Wang
Xiaoyan Wang
LSLipeng Sun
Lipeng Sun
HWHui Wang
Hui Wang
Background: Superb microvascular imaging (SMI) is a new ultrasound vascular imaging technology, which uses a new Doppler algorithm, it has the characteristics of high sensitivity and high resolution to detect low velocity blood flow; it is easier to detect microvessels with low-velocity flow compared with color Doppler flow imaging in theory; and it can image the microvessels of the lesion without angiography. [1] Previous studies showed that SMI can detect tumor neovascularization to differentiate benign from malignant focal liver lessions (FLLs). However, the results of these studies have been contradictory with low sample sizes. This meta-analysis tested the hypothesis that SMI is accurate in distinguishing benign and malignant FLLs. Methods: We will search PubMed, Web of Science, Cochrane Library, and Chinese biomedical databases from their inceptions to the November 30, 2020, without language restrictions. Two authors will independently carry out searching literature records, scanning titles and abstracts, full texts, collecting data, and assessing risk of bias. Review Manager 5.2 and Stata14.0 software will be used for data analysis. Results: This systematic review will determine the accuracy of SMI in the differential diagnosis between benign and malignant FLLs. Conclusion: Its findings will provide helpful evidence for the accuracy of SMI in the differential diagnosis between benign and malignant FLLs. Systematic review registration: INPLASY2020120081.