Alain Bergel

Alain Bergel

Auto-generated profile, based on publicly available information

Alain Bergel

Laboratoire de Génie Chimique, Université de Toulouse, CNRS, INPT, UPS, Toulouse, France

Research Focus & Metrics

Academic Career Length

43Years (1984-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Applied Energy
Verified
Journal Article
Closed access
RRRaphaël Rousseau
Raphaël Rousseau
LELuc Etcheverry
Luc Etcheverry
EREmma Roubaud
Emma Roubaud
RBRegine Basseguy
Regine Basseguy
MDMarie-Line Délia
Marie-Line Délia
ABAlain Bergel
Alain Bergel

1 December 2007 in Electrochimica Acta
Verified
Journal Article
Closed access
Claire DumasClaire Dumas
Claire Dumas
AMA. Mollica
A. Mollica
DFD. Féron
D. Féron
RBRegine Basseguy
Regine Basseguy
LEL. Etcheverry
L. Etcheverry
ABA. Bergel
A. Bergel

1 September 2005 in Electrochemistry Communications
Verified
Journal Article
Closed access
ABAlain Bergel
Alain Bergel
DFDamien Féron
Damien Féron
AMAlfonso Mollica
Alfonso Mollica

21 May 2012 in ChemSusChem
Verified
Journal Article
Closed access
PDF file
BEBenjamin Erable
Benjamin Erable
DFDamien Féron
Damien Féron
ABAlain Bergel
Alain Bergel

11 September 2012 in Energy & Environmental Science
Verified
Journal Article
Closed access
PDF file
DPDiana Pocaznoi
Diana Pocaznoi
ACAmandine Calmet
Amandine Calmet
LELuc Etcheverry
Luc Etcheverry
BEBenjamin Erable
Benjamin Erable
ABAlain Bergel
Alain Bergel
The abilities of carbon cloth, graphite plate and stainless steel to form microbial anodes were compared under identical conditions. Each electrode was polarised at −0.2 V vs. SCE in soil leachate and fed by successive additions of 20 mM acetate. Under these conditions, the maximum current densities provided were on average 33.7 A m−2 for carbon cloth, 20.6 A m−2 for stainless steel, and 9.5 A m−2 for flat graphite. The high current density obtained with carbon cloth was obviously influenced by the three-dimensional electrode structure. Nevertheless, a fair comparison between flat electrodes demonstrated the great interest of stainless steel. The comparison was even more in favour of stainless steel at higher potential values. At +0.1 V vs. SCE stainless steel provided up to 35 A m−2, while graphite did not exceed 11 A m−2. This was the first demonstration that stainless steel offers a very promising ability to form microbial anodes. The surface topography of the stainless steel did not significantly affect the current provided. Analysis of the voltammetry curves allowed two groups of electrode materials to be distinguished by their kinetics. The division into two well-defined kinetics groups proved to be appropriate for a wide range of microbial anodes described in the literature.

1 June 2008 in Electrochimica Acta
Verified
Journal Article
Closed access
Claire DumasClaire Dumas
Claire Dumas
RBRegine Basseguy
Regine Basseguy
ABAlain Bergel
Alain Bergel