30 September 2021 in Medical Engineering & Physics
Femoral neck fractures (FNFs) in young patients usually result from high-energy violence, and the vertical transcervical type is typically challenging for its instability. FNFs are commonly treated with three cannulated screws (CS), but the role of screws type on fixation effects (FE) is unclear. The purpose of this study was to evaluate the FE of ten types of CS with different diameters, lengths, depths, and pitches of thread via finite element analysis which was validated by a biomechanical test. Ten vertical FNF models were grouped, fixed by ten types of CS, respectively, all in a parallel, inverted triangular configuration. Their FE were scored comprehensively from six aspects via an entropy evaluation method, as higher scores showed better results. For partial-thread screws, thread length and thread shape factor (TSF) are determinative factors on stability of FNF only if thread depth is not too thick, and they have less cut-out risk, better compression effects and better detached resistance of fracture than full-thread screws, whereas full-thread screws appear to have better shear and shortening resistance. A combination of two superior partial-thread screws and one inferior full-thread screw for vertical FNF may get optimal biomechanical outcomes. The type of cannulated screw is important to consider when treating vertical FNF.
15 November 2021 in Archives of Osteoporosis
1 April 2022 in Journal of Shoulder and Elbow Surgery
2 June 2020 in IEEE Access
Gait retraining to reduce knee loading has been proposed as a conservative treatment option for early-stage knee osteoarthritis. Mounting evidence suggests that a subject-specific approach may be most effective for ensuring consistent knee loading reductions across all individuals within a population. However, it is currently unclear how to determine the required gait modification dosage selection type and amount to both reduce knee loading and satisfy individual preferences. To overcome this challenge, we introduce a novel, mapping-based dosage selection approach to systematically determine multi-parameter gait modifications to reduce knee loading while maintaining individual user preference. In this approach, individuals first explore different dosages of multi-parameter gait modifications, and then a resulting visual map is displayed with a subject-specific dosage selection zone for the target knee loading reduction. Subjects then self-select a preferred gait within their dosage selection zone. To evaluate the feasibility of this approach, fifteen healthy subjects and one knee OA patient performed walking trials on a treadmill involving various dosages of gait modifications to foot progression angle and step width. Subjects quickly selected the subject-specific gait modifications via mapping-based dosage selection during a single 6 min trial, which reduced the knee adduction moment by an average of 14.2%. Resulting subject-specific gait modifications varied, with 6 subjects selecting only toe-in, 5 subjects selecting both toe-in and increased step width, 2 subjects selecting only toe-out, 1 subject selecting both toe-out and increased step width and 1 subject selecting only increased step width. Average perceived exertion was “fairly light” (index was 10.5±2.2). The knee OA patient selected only toe-in and reduced the knee adduction moment by 12.8%. The presented mapping-based dosage selection approach could provide a systematic and practical means to determine subject-specific gait modifications while maintaining individual preferences.
13 April 2023 in Orthopaedic Surgery
Objective: Open arthrolysis (OA) combined with hinged external fixator (HEF) is a promising surgical option for patients with elbow stiffness. This study aimed to investigate elbow kinematics and function following a combined treatment with OA and HEF in elbow stiffness cases.Methods: Patients treated with OA with or without HEF due to elbow stiffness were recruited between August 2017 and July 2019. Elbow flexion‐extension motion and function (Mayo elbow performance scores, MEPS) were recorded and compared between patients with and without HEF during a 1‐year follow‐up period. Additionally, those with HEF were assessed by dual fluoroscopy at week 6 postoperatively. Flexion‐extension and varus‐valgus motions, as well as ligament insertion distances of the anterior medial collateral ligament (AMCL) and lateral ulnar collateral ligament (LUCL), were compared between the surgical and intact sides.Results: This study included 42 patients, of which 12 with HEF demonstrated a similar flexion‐extension angle and range of motion (ROM) and MEPS as the other patients. In patients with HEF, the surgical elbows showed limitations in flexion‐extension (maximal flexion, 120.5° ± 5.3° vs 140.4° ± 6.8°; maximal extension, 13.1° ± 6.0° vs 6.4° ± 3.0°; ROM, 107.4° ± 9.9° vs 134.0° ± 6.8°; all Ps < 0.01) compared with the contralateral sides. During elbow flexion, a gradual valgus‐to‐varus transition of the ulna, increase in the AMCL insertion distance, and steady change in the LUCL insertion distance were observed, with no significant differences between the bilateral sides.Conclusions: Patients treated with OA and HEF demonstrated similar elbow flexion‐extension motion and function to those treated with OA alone. Although the use of HEF could not restore an intact flexion‐extension ROM and might result in some minor but not significant changes in kinematics, it contributed to clinical outcomes comparable to that of the treatment with OA alone.
29 January 2023 in Calcified Tissue International