Yufeng Lu

Yufeng Lu

Auto-generated profile, based on publicly available information

Yufeng Lu

Honghui Hospital,Xi'an Jiaotong University

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2022 in Frontiers in Materials
Verified
Journal Article
Open access
LQLiang Qi
Liang Qi
BGBinghua Guo
Binghua Guo
QLQing Lu
Qing Lu
HGHanghui Gong
Hanghui Gong
MWMin Wang
Min Wang
YLYufeng Lu
Yufeng Lu
Micro/nanostructured TiO2, ion-doped TiO2, and heterojunction TiO2 composite photocatalysts have low toxicity, high biocompatibility, and high photocatalytic and antibacterial activities and have broad applications in the fields of photocatalytic, antibacterial, and orthopedic implants. The photocatalytic and antibacterial activities of TiO2 and TiO2-based photocatalysts depend on their preparation methods. In this review, the preparation methods of TiO2, ion-doped TiO2, and heterojunction TiO2 composite photocatalysts and their effects on photocatalytic and antibacterial activities were reviewed. Based on the excellent physical and chemical properties of TiO2, ion-doped TiO2, and heterojunction TiO2-based photocatalysts, their applications in the field of orthopedic implants were reviewed. Meanwhile, the development trend of the photocatalyst in the fields of photocatalysis, bacteriostasis, and medicine was prospected. The purpose of this review was to point out the direction for further study on photocatalytic and antibacterial activities and related applications of TiO2 and TiO2-based photocatalysts.

27 March 2020 in Advances in Clinical and Experimental Medicine
Verified
Journal Article
Open access
YLYufeng Lu
Yufeng Lu
QYQingsheng Yu
Qingsheng Yu
WGWanshou Guo
Wanshou Guo
YHYangquan Hao
Yangquan Hao
WSWei Sun
Wei Sun
LCLiming Cheng
Liming Cheng
The pathogenesis of glucocorticoid (GC)-induced osteonecrosis (ON) of the femoral head remains unclear. Recent research has suggested that it is closely associated with injured bone microvascular endothelial cells (BMECs). However, few studies have used BMECs to perform research pertaining ON of the femoral head. The objective of this study was to investigate the functional changes of BMECs treated with a GC and to detect the changes in related genes using microarrays. Cells were isolated using an enzymatic method and identified with EC markers, such as von Willebrand factor (vWF), CD31 and vascular endothelial cadherin (VE-cadherin). Bone microvascular endothelial cells were treated with 0.1 mg/mL and 0.3 mg/mL of hydrocortisone to establish a GC-damaged model of BMECs. The mRNA microarrays were used to detect the differential expression profiles between BMECs with and without GC damage. Primary cells appeared as having a cobblestone-like morphology. Immunofluorescence staining revealed that the cells were 100% positive for vWF and CD31, and near 100% positive for VE-cadherin. It also confirmed that the cells were BMECs. Bone microvascular endothelial cells treated with 0.1 mg/mL of hydrocortisone showed shrinkage, and those treated with 0.3 mg/mL of hydrocortisone mostly showed apoptosis. The mRNA microarray showed that genes associated with endothelial cells, such as endothelin 1 (ET-1) receptor, angiotensin II (AII) receptor, intercellular adhesion molecule 1 (ICAM-1), and plasminogen activator inhibitor 1 (PAI-1), were upregulated, and genes associated with endothelial nitric oxide synthase (eNOS), endothelin 1 (ET-1), prostaglandin I2 (PGI2) synthase, PGI2 receptor, vascular endothelial growth factor (VEGF), prostaglandin E (PGE) synthase, and PGE receptor were downregulated. The results of quantitative polymerase chain reaction (qPCR) validation were consistent with the findings of mRNA microarrays. Glucocorticoids promoted BMECs to express vasoconstrictors and procoagulant factors and related receptors, and decreased the expression of vasodilators and their receptors.

17 November 2022 in European Journal of Medical Research
Verified
Journal Article
Open access
PDF file
YLYufeng Lu
Yufeng Lu
JLJinfeng Li
Jinfeng Li
FQFeng Qiao
Feng Qiao
ZXZhaochen Xu
Zhaochen Xu
BZBaogang Zhang
Baogang Zhang
XCXiaoming Cao
Xiaoming Cao
Purpose: Our goal was to examine the therapeutic effect of a self-designed digital six-axis external fixator technique for the correction of severe lower extremity deformities. Patients and methods: Between January 2017 and December 2020, our institution employed self-developed digital hexapod external fixator technology (QSF), based on CT data, to gradually correct 28 severe tibial deformities, and 15 femurs underwent osteotomy and internal fixation. The mean patient age was 32.6 ± 14.3 years, and the mean follow-up duration was 27.4 ± 16.1 months. We also recoded and analyzed the values of preoperative and final follow-up MAD, mFTA, MPTA, LLD, mLDFA, LEFS, KSS, and functional score. Results: The QSF adjustment duration was 21.4 ± 10.8 days, and the healing duration of the tibial osteotomy site was 17.6 ± 7.0 weeks. The preoperative MAD, mFTA, and MPTA were 54.1 ± 26.2 mm, 167.7 ± 15.7°, and 75.2 ± 12.0°, respectively. At the last follow-up, the MAD was 8.2 ± 9.9 mm, mFTA was 177.6 ± 3.4°, and MPTA was 87.6 ± 2.4°. Based on these data, we achieved significant improvement post operation. The preoperative LLD and mLDFA values were 13.8 ± 18 mm and 83.7 ± 10.8°, respectively, and the values were 7.6 ± 7.6 mm and 87.8 ± 2.6°, respectively, at the last follow-up. This indicated no significant difference in these values before and after the operation. Finally, the LEFS, KSS, and functional scores improved from preoperative 51.6 ± 11.2, 68.5 ± 11.7, and 67.8 ± 11.2 to postoperative 72.3 ± 6.1, 92.9 ± 3.4, and 94.2 ± 6.3, respectively. Conclusions: Based on our analyses, the QSF technique accurately corrected severe multiplanar tibial deformities in adults. When combined with femoral osteotomy, satisfactory lower extremity alignment was obtained while correcting for femoral deformity. This technology has the advantages of simple operation, reliable fixation, less trauma, and less complications.

19 November 2020 in Research Square
Verified
Preprint
Open access
PDF file
YLYufeng Lu
Yufeng Lu
XYXuechao Yuan
Xuechao Yuan
FQFeng Qiao
Feng Qiao
YHYangquan Hao
Yangquan Hao
Objective For total knee arthroplasty (TKA) tibial bone resection, various manufacturers provide cutting blocks with fixed angles. But the accuracy of these angles is uncertain. Our aim was to assess the accuracy of the obtained posterior tibial slope (PTS) with a fixed angle cutting block.Methods 247 TKAs in 213 patients were reviewed. We included 104 Legion Prosthesis, 76 U2 Knee Prosthesis, 46 NexGen LPS-Flex Prosthesis, and 21 Vanguard Knee System products. Preoperative and postoperative PTS were measured via expanded lateral tibia radiographs. The tibial component coronal alignment angle (TCCA) was measured on postoperative standing full-length anteroposterior radiographs, and the tibia length was measured on preoperative standing full-length radiographs. Results For postoperative PTS, the Legion group had significantly smaller slopes than the U2 Knee group and Vanguard group. However, there was no significant difference between the Legion and NexGen groups, and no significant difference among the NexGen, U2 Knee, and Vanguard groups. One sample t-test indicated that only the NexGen group showed no statistical difference from the 7° PTS and 90° TCCA it aimed to provide. Multiple linear regression showed that the different tibial lengths and preoperative PTS had statistically significant effect on postoperative PTS. However, there were weak correlations between the tibial length and PTS, and between preoperative and postoperative PTS.Conclusion For TKA, using conventional tibial bone resection technology with different tibial cutting instrumentations provided by various manufacturers can obtain safe PTS. However, the PTS is not completely consistent with the angle of the cutting block.

13 March 2020 in Research Square
Verified
Preprint
Open access
PDF file
YLYufeng Lu
Yufeng Lu
XYXuechao Yuan
Xuechao Yuan
PXPeng Xu
Peng Xu
YHYangquan Hao
Yangquan Hao
Background Although the tip of the greater trochanter is widely used in THA to adjust leg length discrepancy (LLD), its accuracy and reliability are still unknown. The aim of this study was to investigate the reliability of measuring LLD in patients with total hip arthroplasty using the distance from the tip of the greater trochanter to the inter-teardrop line Methods 128 patients who underwent THA in our department with preoperative and postoperative bilateral hips anteroposterior(AP) radiographs were reviewed. The distance between the bilateral anterior superior iliac spine and the medial malleolus (ASIS-MM) was measured before and after the operation. The distances from the vertex of the lesser trochanter to the bi-ischial line(LT-BI), the distance from the vertex of the lesser trochanter to the inter-teardrop line(LT-IT) and the distance from the tip of greater trochanter to the inter-teardrop line(GT-IT) were measured on the bilateral hips AP radiograph preoperatively and postoperatively. Taking X-ray magnification into account when measuring data. Use one-way ANOVA and paired t test to compare the differences between the four methods. The agreements between the four methods was evaluated using Bland-Altman analysis. Results There was no statistical difference between the four methods. Comparing GT-IT with MM-ASIS, ,LT-IT and LT-BI, the preoperative P values were 0.369, 0.581, and 0.402, and the postoperative P values were 0.755, 0.502 and 0.233. Comparing LT-BI with MM-ASIS and LT-IT, the P values were 0.151 and 0.372 preoperatively, and 0.179 and 0.917 postoperatively. Comparing LT-IT with MM-ASIS, the P value was 0.924 before surgery and 0.291 after surgery. Bland-Altman indicated that there were good agreements between GT-IT and LT-IT. Conclusion It is highly reliable to evaluate the LLD of patients with THA by using the difference in the distance between the tip of the greater trochanter and the inter-teardrop line.

23 April 2020 in Research Square
Verified
Preprint
Open access
PDF file
YLYufeng Lu
Yufeng Lu
XRXiaoyu Ren
Xiaoyu Ren
BLBenyin Liu
Benyin Liu
PXPeng Xu
Peng Xu
YHYangquan Hao
Yangquan Hao
Background: Consensus on tibial rotation in total knee arthroplasty (TKA) remains controversial. The present study aimed to investigate the closest anatomical reference to surgical epicondylar axis (SEA) among 10 tibial markers in Chinese adults.Methods: This study included examination of 122 normal lower extremities. Briefly, 10 axes were drawn on the axial sections: transverse axis of tibia (TAT), axis of medial edge of patellar tendon (MEPT), axis of medial 1⁄3 of patellar tendon attachment (M1/3), Akagi line, Insall line, axis of medial border of tibial tubercle (MBTT), and axis of anterior border of the tibia 1-4 (ATC1-4). The mean angles between TAT and SEA and that between other axes and the line perpendicular to SEA were measured. Pairwise differences among the 10 tibial axes were examined by applying one-way analysis of variance (ANOVA) and paired t-test.Results: In all the knees, the mean angles of M1/3, Akagi line, Insall line, MBTT, ATC1, ATC2, ATC3, and ATC4 axes were compared to the line perpendicular to the projected SEA and found to be 10.2 ± 5.1°, 1.4 ± 5.0°, 11.9 ± 5.4°, 3.6 ± 4.8°, 12.0 ± 6.9°, 7.2 ± 8.6°, 7.1 ± 10.4°, and 6.6 ± 13.5° external rotation, respectively, and the MEPT axis was 1.6 ± 4.5° internal rotation. The mean angle for TAT was 4.1 ± 5.3° external rotation. The M1⁄3 and Insall line were significantly more externally rotated than Akagi line, MEPT, MBTT, TAT, ATC2, ATC3, and ATC4 axes. No significant differences were noted between the TAT axis and the MBTT axis and among the ATC2, ATC3, and ATC4 axes.Conclusion: The Akagi line, MBTT, and TAT showed good consistency with SEA in the axial femorotibial alignment with knee in extension. The middle segment of the anterior tibial crest also demonstrated good alignment consistency with SEA for the axial femorotibial alignment. Hence, these markers can be used as reliable references for rotational alignment of the tibial component in TKA.