This case report describes the treatment of two patients who presented with single edentulous sites in the region of upper premolars and were rehabilitated through the placement of injection‐molded 2‐piece zirconia implants and immediate single crowns. Three months after surgery, definitive prostheses were confectioned through digital workflow. Both patients were followed for 12 months during which clinical and radiographic implant success were observed, concerning implant stability, absence of peri‐implantitis signs, complete implant osseointegration, good marginal bone‐level maintenance, and excellent soft tissue esthetics. No biological or mechanical complications were observed within this period.
This study tested the fracture strength of prosthetic abutments with different sizes and combinations to support a 5-implant milled framework with distal extension. Prosthetic abutments with different dimensions (4.8-mm diameter mini conical abutment and 3.5-mm diameter microconical abutment) were screwed to 5 threaded implants. The following groups were divided (n = 3): G1 with 5 miniconical abutments (standard size), G2 with 5 microconical abutments (small sized), G3 with a combination of 3 small sized abutments and 2 standard sized abutments, and G4 with a combination of 2 small sized abutments and 3 standard sized abutments. Standardized titanium frameworks for full-arch fixed dental prosthesis were milled with equidistant holes for each of the 5 implants and abutments. A loading point was selected at 18 mm away from both distal implants. A universal testing system was used for the fracture strength tests and load was applied at a crosshead speed of 0.5 mm/min on the previously described loading points until component fracture. Mean fracture strength for each group was statistically compared (α = 0.05). Prosthetic screws were the only fractured components for all tested groups. Mean fracture strength was: G1, 1130.22 N; G2, 1031.36 N; G3, 757.9 N; and G4 792.03 N (P < .05). All prosthetic abutments and combinations that were tested provide adequate fracture strength for clinical use. However, the combination of standard and small diameter abutments leads to lower fracture strength compared with when only standard sized prosthetic abutments were used, irrespective of the abutment diameter (4.8- or 3.5-mm).
Narrow‐diameter implants (≤3.5 mm) have been proposed to address the challenge of implant placement in cases of insufficient bone quantity, thin alveolar crest, and small cervical diameter teeth replacement The aim of this study is to report one‐year outcomes of extra‐narrow implant rehabilitation of maxillary lateral incisors, due to agenesis, in a young adult that presented sites with reduced mesiodistal and buccolingual dimensions. A 26‐year‐old male patient in need of fixed‐implant supported prostheses due to the absence of permanent maxillary lateral incisors and with limited space, was submitted to surgery to receive two 2.9 mm hybrid Morse taper connection implants with hydrophilic surfaces. Immediate loading was applied by means of insertion of provisional prostheses, which were replaced for all‐ceramic prostheses 12 months after surgery. The 1 year follow‐up showed clinical and radiographic success of extra‐narrow implant rehabilitation. Also, both regions presented good evolution of peri‐implant esthetics, as assesses using the pink esthetic score, with improvements at 4 months follow‐up and reaching high scores 12 months after surgery. Although the prosthetic rehabilitation of maxillary lateral incisors is challenging due to limited space for the insertion of implants, the clinical case suggests that the use of extra‐narrow Morse Taper implants with hybrid design and hydrophilic surface is a reliable alternative, presenting good outcomes regarding hard and soft tissue and it is a versatile solution or immediate loading procedure. Further studies are needed to confirm extra‐narrow implant predictability.
Introduction The long-term implant-supported prosthetic rehabilitation monitoring is extremely important in evaluating parameters that could interfere in the success of the treatment. Objective To evaluate the influence of macrodesign (shape of the body and apex), length and diameter, insertion torque, site of installation as well as the loading protocol, on long-term survival rates. Material and method The data obtained was from the medical records of rehabilitated patients who had had at least one Morse taper implant surgery done at ILAPEO School between 2006 -2012. Incomplete medical records, from which it would have been impossible to extract all data essential to complete the study, were excluded. Result A total of 1,142 patient’s medical records comprised the sample; documenting the progress of 5,601 implants, done in both jaws and mandibles. The final survival rate was 98.31%, over an average time of 37.54 months. The type of implant most used was cylindrical (70.33%). The mean installation torque most evidenced in the study was between 41 and 50 Ncm. A logistical regression analysis showed that none of the following variables, site of installation, body and apex shape designs and length, had any significant statistical influence on implant loss. Torque increase and diameter influenced implant loss while immediate loading favored implant maintenance. Conclusion It can be concluded that Morse taper implants present a long-term survival rate that can be lowered by excessive torque, as well as by the diameter of the implant.
1 January 2023 in RGO - Revista Gaúcha de Odontologia
Objective: The aim of this study was to compare the stress distribution in internal tapered connection implants with different adaptation geometries submitted to oblique load simulation using the Finite Element Analysis (FEA) method. Methods: Three different internal tapered implant-abutment assemblies were modeled by varying only the diameter of the abutment body in the cone region. The dimensions of the implants were 4.0 mm in diameter and 13 mm in length. Oblique loads of 210 N angled 30 degrees to the long axis of the implant were applied to a hemispherical body positioned over the abutments simulating a dental crown. The stress generated by the implant-abutment assembly was analyzed by the FEA method using the von Mises criterion. Results: A higher concentration of stress in the coronal region (collar) and implant body on the opposite side of the load application was shown, as well as in the body region of the abutments and in the screw threads. The cervical region of the implants showed the highest von Mises stress values, the highest values being observed in G3 (1034 MPa), followed by G2 (841 MPa) and G1 (702 MPa). Conclusion: According to the results presented, it can be concluded that the stress distribution was more homogeneous and less concentrated in the G1 implant-abutment assembly. Therefore, the use of abutments with dimensions standardized by the implant manufacturer is recommended.
1 January 2020 in RGO - Revista Gaúcha de Odontologia
Precise planning for dental implant placement requires appreciation of anatomical limitations and restorative purpose. Diagnosis can be made by complementary exams such as panoramic radiography and cone-beam computed tomography. The purpose of this study was to rehabilitate the upper and lower jaw of a patient with severe periodontal disease using a guided osteotomy and implants placed with free hands and Morse taper implants. The concept of guided surgery was used to prepare the alveolar bone to place eight implants, four implants in the upper jaw and four implants in the lower jaw, all have achieved a minimum torque of 60 Ncm. The modified suture technique was used to better stabilize the soft tissue around the mini conical abutments. The analogues were scanned by CAD/CAM for confection of the metallic structures of the bridges. On the third day, the upper and lower full arch prostheses were installed and simultaneous bilateral contacts were adjusted. After 12 months of patient follow-up, the implants and prostheses were in good condition of aesthetics and function, maintaining the success of the rehabilitation. Within the limitations of this clinical case, it can be concluded that the implants placed with free hands was facilitated by a previous guided osteotomy.