30 August 2018 in Journal of Materials Chemistry B
We present an antibacterial polymersome–hydrogel composite that combines the advantages of both antimicrobial peptides and antibiotics. The polymersomes are self-assembled from poly(ε-caprolactone)-block-poly(lysine-stat-phenylalanine) [PCL-b-P(Lys-stat-Phe)], exhibiting long-acting intrinsic antibacterial capabilities against both Gram-positive and Gram-negative bacteria. In addition, penicillin is encapsulated into the polymersomes, showing quick and enhanced antibacterial activities. Furthermore, a dynamic hydrogel network is prepared based on the Schiff base linkages between the aldehyde groups of dibenzaldehyde-functionalized PEG (DF-PEG) and the amino groups of chitosan. During this process, the penicillin-loaded polymersomes are grafted into the hydrogel networks by Schiff base linkages to afford polymersome–hydrogel composites, which exhibit two-stage antibacterial behavior: (1) penicillin can be released from the hydrogel networks for quick antibacterial function; (2) the polymersomes and the remaining penicillin can be further released for long-term antibacterial effects. Overall, this polymersome–hydrogel composite represents a new type of injectable antibacterial biomaterial for quick and long-acting antibacterial applications.
30 May 2019 in American Journal of Neuroradiology
BACKGROUND AND PURPOSE: 3D reconstruction of a targeted area (“safe” triangle and Kambin triangle) may benefit the viability assessment of transforaminal epidural steroid injection, especially at the L5/S1 level. However, manual segmentation of lumbosacral nerves for 3D reconstruction is time-consuming. The aim of this study was to investigate the feasibility of deep learning–based segmentation of lumbosacral nerves on CT and the reconstruction of the safe triangle and Kambin triangle. MATERIALS AND METHODS: A total of 50 cases of spinal CT were manually labeled for lumbosacral nerves and bones using Slicer 4.8. The ratio of training/validation/testing was 32:8:10. A 3D U-Net was adopted to build the model SPINECT for automatic segmentations of lumbosacral structures. The Dice score, pixel accuracy, and Intersection over Union were computed to assess the segmentation performance of SPINECT. The areas of Kambin and safe triangles were measured to validate the 3D reconstruction. RESULTS: The results revealed successful segmentation of lumbosacral bone and nerve on CT. The average pixel accuracy for bone was 0.940, and for nerve, 0.918. The average Intersection over Union for bone was 0.897 and for nerve, 0.827. The Dice score for bone was 0.945, and for nerve, it was 0.905. There were no significant differences in the quantified Kambin triangle or safe triangle between manually segmented images and automatically segmented images (P > .05). CONCLUSIONS: Deep learning–based automatic segmentation of lumbosacral structures (nerves and bone) on routine CT is feasible, and SPINECT-based 3D reconstruction of safe and Kambin triangles is also validated.
1 October 2020 in International Journal of Surgery
Deep learning has been validated as a promising technique for automatic segmentation and rapid three-dimensional (3D) reconstruction of lumbosacral structures on CT. Simulated foraminoplasty of percutaneous endoscopic transforaminal discectomy (PETD) through the Kambin triangle may benefit viability assessment of PETD at L5/S1 level. Medical records and radiographic data of patients with L5/S1 lumbar disc herniation (LDH) who received a single-level PETD from March 2013 to February 2018 were retrospectively collected and analyzed. Deep learning was adopted to achieve semantic segmentation of lumbosacral structures (nerve, bone, disc) on CT, and the segmented masks on reconstructed 3D models. Two observers measured the area of the Kambin triangle on 6 selected deep learning-derived 3D (DL-3D) models and ground truth-derived 3D (GT-3D) models, and intraclass correlation coefficient (ICC) was calculated to assess the test-retest and interobserver reliability. Foraminoplasty of PETD was simulated on L5/S1 lumbosacral 3D models. Patients with extended foraminoplasty or stuck canula occurs on simulations were predicted as PETD-difficult cases (Group A). The remaining patients were regarded as PETD-normal cases (Group B). Clinical information and outcomes were compared between the two groups. Deep learning-derived 3D models of lumbosacral structures (nerves, bones, and disc) from thin-layer CT were reliable. The area of the Kambin triangle was 161.27 ± 40.10 mm2 on DL-3D models and 153.57 ± 32.37 mm2 on GT-3D models (p = 0.206). Reliability test revealed strong test-retest reliability (ICC between 0.947 and 0.971) and interobserver reliability of multiple measurements (ICC between 0.866 and 0.961). The average operation time was 99.62 ± 17.39 min in Group A and 88.93 ± 21.87 min in Group B (P = 0.025). No significant differences in patient-reported outcomes or complications were observed between the two groups (P > 0.05). Deep learning achieved accurate and rapid segmentations of lumbosacral structures on CT, and deep learning-based 3D reconstructions were efficacious and reliable. Foraminoplasty simulation with deep learning-based lumbosacral reconstructions may benefit surgical difficulty prediction of PETD at L5/S1 level.
8 May 2020 in Skeletal Radiology