Hang Xu

Hang Xu

Auto-generated profile, based on publicly available information

Hang Xu

Engineering Technology Research Institute of PetroChina Xinjiang Oilfield Company, Karamay 834000, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
Er-dong YaoEr-dong Yao
Er-dong Yao
HXHang Xu
Hang Xu
YLYuan Li
Yuan Li
XRXuesong Ren
Xuesong Ren
HBHao Bai
Hao Bai
Fujian ZhouFujian Zhou
Fujian Zhou
Economical and environmental concerns have forced the oil and gas industry to consider reusing flowback and produced water for fracturing operations. The major challenge is that the high-salinity of flowback water usually prevents its compatibility with several fracturing fluid additives. In this paper, the authors explored an economic and effective method to prepare guar fracturing fluids with different salinity waters. The main research idea was to use chelating agents to mask metal ions, such as calcium and magnesium, that are harmful to crosslinking. Firstly, a complexometric titration test was conducted to measure the chelating ability of three chelating agents. Secondly, through viscosity, crosslinking, and hanging tests, it was verified that the complex masking method could cope with the problem of high-valence metal ions affecting crosslinking. Thirdly, the preferred chelating agent was mixed with several other additives, including thickeners, crosslinkers, and pH regulators, to prepare the novel guar fracturing fluid. The comprehensive performances of the novel fluid system were tested such as temperature and shear resistance, friction reduction, gel-breaking performance, and core damage rate. The results show that the organophosphate chelating agent (i.e., CA-5) had the greatest ability to chelate calcium and magnesium ions. There was a good linear relationship between the dosage of CA-5 and the total molar concentration of calcium and magnesium ions in brine water. The main mechanism was that the chelating agent formed a complex with calcium and magnesium ions at a chelation ratio of 1:5. The test results of the comprehensive performance evaluation indicate that the prepared guar fracturing fluid met the requirements for field application, and the lower the salinity of the flowback water, the more it is economical and effective.

21 July 2022 in Energies
Verified
Journal Article
Open access
PDF file
YLYuan Li
Yuan Li
Fujian ZhouFujian Zhou
Fujian Zhou
Jie WangJie Wang
Jie Wang
BLBojun Li
Bojun Li
HXHang Xu
Hang Xu
LZLongHao Zhao
LongHao Zhao
During the production process, water phase incursion into the reservoir causes water blocking damage and seriously affects the production of tight gas reservoirs. Recently, nanoemulsions have been used as highly effective water blocking removing agents in the field, but their mechanism is still unclear. In this research, a series of nanoemulsions with different droplet sizes were synthesized, and their water blocking removing performance was intensively investigated. To begin, the relationship between the droplet size and the chemical composition of the nanoemulsion was determined by dynamic light scattering. Second, the influence of the nanoemulsion droplet size on the surface tension and the contact angle experiments was studied. Finally, NMR and permeability recovery experiments were used to study the relationship between the droplet size and the water locking removing effect of the nanoemulsions. Simultaneously, the surfactant release process was investigated using the static adsorption curves of the nanoemulsions. The experimental results show that the droplet size of nanoemulsion has an exponential relationship with the oil phase content. The surface tension decreases with the increase in droplet size, but the wetting reversal effect decreases with the increase in droplet size. The nanoemulsion with an oil phase content of 5 wt.% has the best water locking removing effect, and the permeability recovery value of the core reaches 59.54%. The adsorption control of the nanoemulsion on the surfactant is the key to its water blocking removing ability. This comprehensive study shows that the nanoemulsion with an oil phase content of 5 wt.% has optimum adsorption control capability. Thus, it can be used as a promising candidate for removing water blocking in tight gas reservoirs.

20 October 2022 in Processes
Verified
Journal Article
Open access
PDF file
MZMiao Zheng
Miao Zheng
LSLianqi Sheng
Lianqi Sheng
HRHongda Ren
Hongda Ren
AYAbulimiti Yiming
Abulimiti Yiming
Er-dong YaoEr-dong Yao
Er-dong Yao
LZLongHao Zhao
LongHao Zhao
The injection water and formation water in the Mahu oil field have high salinity and poor compatibility, which leads to scaling and blockage in the formation or fracture propping zone during production. In this paper, a scale-inhibiting fracturing fluid system is developed which can prevent the formation of scale in the reservoir and solves the problem of scaling in the fracture propping zone at the Mahu oil field. Firstly, based on scale-inhibition rate, the performances of six commercial scale inhibitors were evaluated, including their acid and alkali resistance and temperature resistance. Then, the optimal scale inhibitors were combined with the fracturing fluid to obtain a scale-inhibiting fracturing fluid system. Its compatibility with other additives and scale-inhibition performance were evaluated. Finally, the system’s drag-reduction ability was tested through the loop friction tester. The results showed that, among the six scale inhibitors, the organic phosphonic acid scale inhibitor SC-1 has the best performance regardless of high-temperature, alkaline, and mixed scale conditions. In addition, SC-1 has good compatibility with the fracturing fluid. The scale-inhibiting fracturing fluid system can effectively prevent scaling inside the large pores in the propping zone, and a scale-inhibiting efficiency of 96.29% was obtained. The new fracture system maintained a drag-reduction efficiency of about 75%, indicating that the addition of the scale inhibitor did not cause a significant influence on the drag-reduction efficiency of the fracturing fluid.