1 June 2020 in IEEE Transactions on Instrumentation and Measurement
The Wavelength Modulation Spectroscopy (WMS) method is typically used in the Tunable Diode Laser Absorption Spectroscopy (TDLAS) for spectrum extraction in noisy background. Usually, two entire absorption spectra for target species are scanned in a cascade way in the WMS method, and it limits the temporal response of the TDLAS sensor. In this paper, the frequency division multiplexing and main peak scanning method were introduced to the WMS method and enabled a high frame rate six times of that in the classical TDLAS sensor at the same scanning speed. For the first time, two wavelengths modulated at different frequencies were used to extract the absorptions in parallel along various laser paths and implemented successfully on a TDLAS tomography hardware, to reconstruct the distributions of both temperature and specie concentrations, at a frame rate upto 10kHz. A five-view fan-beam tomographic sensor was utilized in the tomographic imaging. In each view, lasers at two wavelengths were selected and modulated at different sinusoidal frequencies on the same sawtooth signal. Numerical simulations varied the high-quality tomographic imaging of both temperature and H2O molar concentration distributions for different phantoms. Experiments were also carried out on dynamic flames, which were generated by exciting a Bunsen burner acoustically. The acoustic excitation frequency varied from 40 Hz to 750 Hz and results of the tomographic images agreed well with the flame evolutions.
27 December 2019 in IEEE Sensors Journal
A tunable diode laser absorption spectroscopy (TDLAS) tomographic system was proposed via utilizing the wavelength modulation spectroscopy (WMS) method and distributions of temperature and specie concentrations in the dynamic flames were simultaneously reconstructed for the first time. A five-view fan beam tomographic sensor was applied to capture the absorption spectrum along the laser paths across the region to be imaged. Light intensities in all paths were collected in a custom specific TDLAS hardware. Different phantoms of the temperature and water vapor concentration distributions were fabricated to generate artificial data of the absorption spectrum acquired in the sensor. Reconstructed images of the phantoms in the simulations agreed well with the original distributions, in cases of different random noises that varied from 1% to 7% of light intensities at each wavelength. Experiments on a McKenna burner and the exit of a wind tunnel were carried out, and distributions of temperature and water vapor’s molar concentration were achieved by applying the proposed WMS based TDLAS tomographic system. A moving steel ruler was used to disturb the flame in the burner and temporal variations of the flame over a cross section of the burner were imaged in a tomographic way. Tomographic results on exhaust flows at the exit of a wind tunnel coincided with the variation trend of temperature in eleven different working conditions and verified the robustness of the proposed system under harsh conditions.
4 May 2020 in IEEE Transactions on Instrumentation and Measurement
A compact hardware system for laser absorption spectroscopy tomography is introduced to monitor dynamic flame evolution with a short and fixed spectral scanning time and an adjustable frame rate. The system mainly consists of two parts, a pentagon sensor and a reconfigurable laser control and data acquisition hardware. In the sensor, twelve photodetectors are installed in each of the five sides of the pentagon. Fan-shaped laser beams from each vertex illuminate the opposite side and half of its two adjacent sides. Compared with the traditional illuminating scheme from each vertex to only the opposite side, this design reduces the sensor size and improves the spatial resolution. In the hardware, the distributed feedback lasers are integrated with the controller and modulated to generate a programmed waveform and implement spectral scanning. The spectral scanning time is short and fixed, and an adjustable frame rate is achieved by changing the interval, i.e. the waiting time, between two successive scans. The sampling rate of each channel can reach up to 20 MHz and is synchronized to the laser emission. A DDR2 memory is used for temporary data storage for four channels, enabling a full frame rate of up to 2 kHz. In the experiment, water vapor in a flat flame burner was chosen as the target absorbing species. Local integral absorbance and temperature distributions in the case of a moving steel ruler across the burner were reconstructed and agreed well with the observed distributions.