Dominik Korol

Dominik Korol

Auto-generated profile, based on publicly available information

Dominik Korol

Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2023 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
PLPatrycja Lach
Patrycja Lach
ACALVARO GARCIA CRUZ
ALVARO GARCIA CRUZ
FCFrancesco Canfarotta
Francesco Canfarotta
AGAlistair Groves
Alistair Groves
JKJakub Kalecki
Jakub Kalecki
PSPiyush Sindhu Sharma
Piyush Sindhu Sharma
Redox-active molecularly imprinted polymer nanoparticles selective for glyphosate, MIP-Gly NPs, were devised, synthesized, and subsequently integrated onto platinum screen-printed electrodes (Pt-SPEs) to fabricate a chemosensor for selective determination of glyphosate (Gly) without the need for redox probe in the test solution. That was because, ferrocenylmethyl methacrylate was added to the polymerization mixtures during the NPs synthesis so that the resulting MIP-Gly NPs contained covalently immobilized ferrocenyl moieties as the reporting redox ingredient, conferring these NPs with electroactive properties. MIP-Gly NPs of four different compositions were evaluated. The herein described approach represents a simple and effective way to endow MIP NPs with electrochemical reporting capabilities with neither the need to functionalize them post-synthesis nor to use electrochemical mediators present in the tested solution during the analyte determinations. MIP-Gly NPs synthesized using allylamine and squaramide-based monomers appeared most selective to Gly. The Pt-SPEs modified with MIP-Gly NPs were characterized with differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). Changes in the DPV peak originating from the oxidation of the ferrocenyl moieties in these MIP-Gly NPs served as the analytical signal. The DPV limit of detection and the linear dynamic concentration range for Gly were 3.7 pM and 25 pM-500 pM, respectively. Moreover, the selectivity of the fabricated chemosensors was sufficiently high to determine Gly successfully in spiked river water samples.

1 September 2021 in Electrochimica Acta
Verified
Journal Article
Closed access
AKAnna Kisiel
Anna Kisiel
DKDominik Korol
Dominik Korol
AAgata Michalska
Agata Michalska
KMKrzysztof Maksymiuk
Krzysztof Maksymiuk

11 December 2025 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
MCMaciej Cieplak
Maciej Cieplak
DKDominik Korol
Dominik Korol
PSPiyush Sindhu Sharma
Piyush Sindhu Sharma

28 April 2025 in The Analyst
Verified
Journal Article
Open access
PDF file
DKDominik Korol
Dominik Korol
KNKostiantyn Nikiforow
Kostiantyn Nikiforow
PBPaweł Borowicz
Paweł Borowicz
PSPiyush Sindhu Sharma
Piyush Sindhu Sharma
MCMaciej Cieplak
Maciej Cieplak
Carbon paper was used as a cost-effective and flexible electrode material. It was coated with polypyrrole film imprinted with metronidazole. Such a prepared sensor was applied for electrochemical determination of the metronidazole.

25 November 2025 in Materials & Design
Verified
Journal Article
Open access
SRSada Raza
Sada Raza
DKDominik Korol
Dominik Korol
EOEnkhlin Ochirbat
Enkhlin Ochirbat
BKBartosz Kamiński
Bartosz Kamiński
MCMaciej Cieplak
Maciej Cieplak
JPJan Paczesny
Jan Paczesny