Low intrinsic noise, high bandwidth, and high accuracy vector magnetometers are key components for many ground or space geophysical applications. Here, we report the design and the test of a 4He vector optically pumped magnetometer specifically dedicated to these needs. It is based on a parametric resonance magnetometer architecture operated in the Earth magnetic field with closed-loop compensation of the three components of the magnetic field. It provides offset-free vector measurements in a ±70 μT range with a DC to 1 kHz bandwidth. We demonstrate a vector sensitivity up to 130 fT/√Hz, which is about ten times better than the best available fluxgate magnetometers currently available for the same targeted applications.
We present here a parametric resonance magnetometer scheme based on elliptically polarized pumping light and two radio frequency fields applied along the two optical pumping directions. At optimum ellipticity and radio frequency fields' amplitudes, the three components of the magnetic field are measured with an isotropic sensitivity. Compared to the usual alignment-based parametric resonance magnetometers, the sensitivity is degraded by a factor of 2 for two components of the magnetic field but improved by a factor of 9 for the third one. The open-loop bandwidth was measured to be greater than 1 kHz for the three axes. This magnetometer configuration could be particularly interesting for geophysics and biomedical imaging.
We study spontaneous photon decay into multiple photons triggered by strong nonlinearities in an experimental simulator of a bosonic quantum impurity model. Previously, spectroscopic signatures of photon conversion were reported and evidenced as resonances in the many-body spectrum of these systems. Here, we report on the observation of multimode fluorescence of a small Josephson junction embedded in a high impedance superconducting transmission line. Measurement of the down-converted photons is achieved using state-of-the-art broadband parametric amplifiers. Photon triplet emission is explicitly demonstrated at a given frequency as the counterpart of inelastic photon decay at 3× the emission frequency. These results open exciting prospects for the burgeoning field of many-body quantum optics and offer a direct signature of the ultrastrong light-matter coupling.
14 October 2024 in Superconductor Science and Technology
Traveling wave parametric amplifiers (TWPAs) are extensively employed in experiments involving weak microwave signals for their highly desirable quantum-limited and broadband characteristics. However, TWPAs’ broadband nature comes with the disadvantage of admitting the activation of spurious nonlinear processes, such as harmonics generation, that can potentially degrade amplification performance. Here we experimentally investigate a Josephson TWPA device with superconducting nonlinear asymmetric inductive element-based unit cells focusing on the amplification behaviour along with the generation of second and third harmonics of the pump. By comparing experimental results with transient numerical simulations, we demonstrate the influence of Josephson junctions’ fabrication imperfections on the occurrence of harmonics and on the gain behaviour.
Optically pumped magnetometers usually rely on optical pumping using circularly or linearly polarized light. We study here zero-field magnetometers pumped with elliptically polarized light, preparing both atomic orientation and alignment with complementary geometries. We start by extending the three-step approach for elliptically polarized pumping. This allows us to study the Hanle effect in elliptical polarization by comparing the analytical absorption signals with experiments made on metastable state. We then study parametric resonance magnetometers based on elliptical polarization by using the dressed-atom formalism with one and two radio-frequency fields. The results show good agreement with the experimental measurements and interesting perspectives for magnetometry where symmetry breaking by pumping light is mitigated.