11 October 2018 in Scientific Reports
The emergence of multiparametric diffusion models combining diffusion and relaxometry measurements provides powerful new ways to explore tissue microstructure, with the potential to provide new insights into tissue structure and function. However, their ability to provide rich analyses and the potential for clinical translation critically depends on the availability of efficient, integrated, multi-dimensional acquisitions. We propose a fully integrated sequence simultaneously sampling the acquisition parameter spaces required for T1 and T2* relaxometry and diffusion MRI. Slice-level interleaved diffusion encoding, multiple spin/gradient echoes and slice-shuffling are combined for higher efficiency, sampling flexibility and enhanced internal consistency. In-vivo data was successfully acquired on healthy adult brains. Obtained parametric maps as well as clustering results demonstrate the potential of the technique to provide eloquent data with an acceleration of roughly 20 compared to conventionally used approaches. The proposed integrated acquisition, which we call ZEBRA, offers significant acceleration and flexibility compared to existing diffusion-relaxometry studies, and thus facilitates wider use of these techniques both for research-driven and clinical applications.
8 November 2017 in Scientific Reports
Neurodevelopmental impairment is the most common comorbidity associated with complex congenital heart disease (CHD), while the underlying biological mechanism remains unclear. We hypothesised that impaired cerebral oxygen delivery in infants with CHD is a cause of impaired cortical development, and predicted that cardiac lesions most associated with reduced cerebral oxygen delivery would demonstrate the greatest impairment of cortical development. We compared 30 newborns with complex CHD prior to surgery and 30 age-matched healthy controls using brain MRI. The cortex was assessed using high resolution, motion-corrected T2-weighted images in natural sleep, analysed using an automated pipeline. Cerebral oxygen delivery was calculated using phase contrast angiography and pre-ductal pulse oximetry, while regional cerebral oxygen saturation was estimated using near-infrared spectroscopy. We found that impaired cortical grey matter volume and gyrification index in newborns with complex CHD was linearly related to reduced cerebral oxygen delivery, and that cardiac lesions associated with the lowest cerebral oxygen delivery were associated with the greatest impairment of cortical development. These findings suggest that strategies to improve cerebral oxygen delivery may help reduce brain dysmaturation in newborns with CHD, and may be most relevant for children with CHD whose cardiac defects remain unrepaired for prolonged periods after birth.
15 December 2017 in Magnetic Resonance in Medicine
Purpose: An extended phase graph framework (EPG‐X) for modeling systems with exchange or magnetization transfer (MT) is proposed.Theory: EPG‐X models coupled two‐compartment systems by describing each compartment with separate phase graphs that exchange during evolution periods. There are two variants: EPG‐X(BM) for systems governed by the Bloch‐McConnell equations, and EPG‐X(MT) for the pulsed MT formalism. For the MT case, the “bound” protons have no transverse components, so their phase graph consists of only longitudinal states.Methods: The EPG‐X model was validated against steady‐state solutions and isochromat‐based simulation of gradient‐echo sequences. Three additional test cases were investigated: (i) MT effects in multislice turbo spin‐echo; (ii) variable flip angle gradient‐echo imaging of the type used for MR fingerprinting; and (iii) water exchange in multi‐echo spin‐echo T2 relaxometry.Results: EPG‐X was validated successfully against isochromat based transient simulations and known steady‐state solutions. EPG‐X(MT) simulations matched in‐vivo measurements of signal attenuation in white matter in multislice turbo spin‐echo images. Magnetic resonance fingerprinting–style experiments with a bovine serum albumin (MT) phantom showed that the data were not consistent with a single‐pool model, but EPG‐X(MT) could be used to fit the data well. The EPG‐X(BM) simulations of multi‐echo spin‐echo T2 relaxometry suggest that exchange could lead to an underestimation of the myelin‐water fraction.Conclusions: The EPG‐X framework can be used for modeling both steady‐state and transient signal response of systems exhibiting exchange or MT. This may be particularly beneficial for relaxometry approaches that rely on characterizing transient rather than steady‐state sequences. Magn Reson Med 80:767–779, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
14 September 2018 in Magnetic Resonance in Medicine
Purpose: This study demonstrates magnetization transfer (MT) effects directly affect relaxometry measurements and develops a framework that allows single‐pool models to be valid in 2‐pool MT systems.Methods: A theoretical framework is developed in which a 2‐pool MT system effectively behaves as a single‐pool if the RMS RF magnetic field ({\text{B}}_{1}^{{{\text{rms}}}}) is kept fixed across all measurements. A practical method for achieving controlled saturation magnetization transfer (CSMT) using multiband RF pulses is proposed. Numerical, Phantom, and in vivo validations were performed directly comparing steady state (SS) estimation approaches that under correct single‐pool assumptions would be expected to vary in precision but not accuracy.Results: Numerical simulations predict single‐pool estimates obtained from MT model generated data are not consistent for different SS estimation methods, and a systematic underestimation of T2 is expected. Neither effect occurs under the proposed CSMT approach. Both phantom and in vivo experiments corroborate the numerical predictions. Experimental data highlights that even when using the same relaxometry method, different estimates are obtained depending on which combination of flip angles (FAs) and TRs are used if the CSMT approach is not used. Using CSMT, stable measurements of both T1 and T2 are obtained. The measured T1 ) depends on {\text{B}}_{1}^{{{\text{rms}}}}, which is therefore an important parameter to specify.Conclusion: This work demonstrates that conventional single pool relaxometry, which is highly efficient for human studies, results in unreliable parameter estimates in biological tissues because of MT effects. The proposed CSMT framework is shown to allow single‐pool assumptions to be valid, enabling reliable and efficient quantitative imaging to be performed.
1 July 2019 in NeuroImage
JTJacques-Donald Tournier
Multicomponent driven equilibrium steady-state observation of T1 and T2 (mcDESPOT) aims to quantify the Myelin Water Fraction (MWF) using a two-pool microstructural model. The MWF has been used to track neurodevelopment and neurodegeneration and has been histologically correlated to myelin content. mcDESPOT has a clinically feasible acquisition time and high signal-to-noise ratio (SNR) relative to other MWF techniques. However, disagreement exists in the literature between experimental studies that show MWF maps with plausible grey matter-white matter (GM-WM) contrast and theoretical work that questions the accuracy and precision of mcDESPOT. We demonstrate that mcDESPOT parameter estimation is inaccurate and imprecise if intercompartmental exchange is included in the microstructural model, but that significant bias results if exchange is neglected. The source of apparent MWF contrast is likely due to the complex convergence behaviour of the Stochastic Region Contraction (SRC) method commonly used to fit the mcDESPOT model. mcDESPOT-derived parameter estimates are hence not directly relatable to the underlying microstructural model and are only comparable to others using similar acquisition schemes and fitting constraints.
3 January 2020 in Magnetic Resonance in Medicine
JOJonathan O'MUircheartaigh
Jonathan O'MUircheartaigh
Purpose: To enable rigid body motion‐tolerant parallel volumetric magnetic resonance imaging by retrospective head motion correction on a variety of spatiotemporal scales and imaging sequences.Theory and methods: Tolerance against rigid body motion is based on distributed and incoherent sampling orders for boosting a joint retrospective motion estimation and reconstruction framework. Motion resilience stems from the encoding redundancy in the data, as generally provided by the coil array. Hence, it does not require external sensors, navigators or training data, so the methodology is readily applicable to sequences using 3D encodings.Results: Simulations are performed showing full inter‐shot corrections for usual levels of in vivo motion, large number of shots, standard levels of noise and moderate acceleration factors. Feasibility of inter‐ and intra‐shot corrections is shown under controlled motion in vivo. Practical efficacy is illustrated by high‐quality results in most corrupted of 208 volumes from a series of 26 clinical pediatric examinations collected using standard protocols.Conclusions: The proposed framework addresses the rigid motion problem in volumetric anatomical brain scans with sufficient encoding redundancy which has enabled reliable pediatric examinations without sedation.