19 May 2015 in NMR in Biomedicine
The development of MRI systems operating at or above 7 T has provided researchers with a new window into the human body, yielding improved imaging speed, resolution and signal‐to‐noise ratio. In order to fully realise the potential of ultrahigh‐field MRI, a range of technical hurdles must be overcome. The non‐uniformity of the transmit field is one of such issues, as it leads to non‐uniform images with spatially varying contrast. Parallel transmission (i.e. the use of multiple independent transmission channels) provides previously unavailable degrees of freedom that allow full spatial and temporal control of the radiofrequency (RF) fields. This review discusses the many ways in which these degrees of freedom can be used, ranging from making more uniform transmit fields to the design of subject‐tailored RF pulses for both uniform excitation and spatial selection, and also the control of the specific absorption rate. © 2015 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.
1 August 2013 in Progress in Nuclear Magnetic Resonance Spectroscopy
10 May 2012 in American Journal of Neuroradiology
SUMMARY: Fetal and neonatal MR imaging is increasingly used as a complementary diagnostic tool to sonography. MR imaging is an ideal technique for imaging fetuses and neonates because of the absence of ionizing radiation, the superior contrast of soft tissues compared with sonography, the availability of different contrast options, and the increased FOV. Motion in the normally mobile fetus and the unsettled, sleeping, or sedated neonate during a long acquisition will decrease image quality in the form of motion artifacts, hamper image interpretation, and often necessitate a repeat MR imaging to establish a diagnosis. This article reviews current techniques of motion compensation in fetal and neonatal MR imaging, including the following: 1) motion-prevention strategies (such as adequate patient preparation, patient coaching, and sedation, when required), 2) motion-artifacts minimization methods (such as fast imaging protocols, data undersampling, and motion-resistant sequences), and 3) motion-detection/correction schemes (such as navigators and self-navigated sequences, external motion-tracking devices, and postprocessing approaches) and their application in fetal and neonatal brain MR imaging. Additionally some background on the repertoire of motion of the fetal and neonatal patient and the resulting artifacts will be presented, as well as insights into future developments and emerging techniques of motion compensation.
11 October 2018 in Scientific Reports
The emergence of multiparametric diffusion models combining diffusion and relaxometry measurements provides powerful new ways to explore tissue microstructure, with the potential to provide new insights into tissue structure and function. However, their ability to provide rich analyses and the potential for clinical translation critically depends on the availability of efficient, integrated, multi-dimensional acquisitions. We propose a fully integrated sequence simultaneously sampling the acquisition parameter spaces required for T1 and T2* relaxometry and diffusion MRI. Slice-level interleaved diffusion encoding, multiple spin/gradient echoes and slice-shuffling are combined for higher efficiency, sampling flexibility and enhanced internal consistency. In-vivo data was successfully acquired on healthy adult brains. Obtained parametric maps as well as clustering results demonstrate the potential of the technique to provide eloquent data with an acceleration of roughly 20 compared to conventionally used approaches. The proposed integrated acquisition, which we call ZEBRA, offers significant acceleration and flexibility compared to existing diffusion-relaxometry studies, and thus facilitates wider use of these techniques both for research-driven and clinical applications.
30 May 2017 in Magnetic Resonance in Medicine
Purpose: Advanced diffusion magnetic resonance imaging benefits from collecting as much data as is feasible but is highly sensitive to subject motion and the risk of data loss increases with longer acquisition times. Our purpose was to create a maximally time‐efficient and flexible diffusion acquisition capability with built‐in robustness to partially acquired or interrupted scans. Our framework has been developed for the developing Human Connectome Project, but different application domains are equally possible.Methods: Complete flexibility in the sampling of diffusion space combined with free choice of phase‐encode‐direction and the temporal ordering of the sampling scheme was developed taking into account motion robustness, internal consistency, and hardware limits. A split‐diffusion‐gradient preparation, multiband acceleration, and a restart capacity were added.Results: The framework was used to explore different parameters choices for the desired high angular resolution diffusion imaging diffusion sampling. For the developing Human Connectome Project, a high‐angular resolution, maximally time‐efficient (20 min) multishell protocol with 300 diffusion‐weighted volumes was acquired in >400 neonates. An optimal design of a high‐resolution (1.2 × 1.2 mm2) two‐shell acquisition with 54 diffusion weighted volumes was obtained using a split‐gradient design.Conclusion: The presented framework provides flexibility to generate time‐efficient and motion‐robust diffusion magnetic resonance imaging acquisitions taking into account hardware constraints that might otherwise result in sub‐optimal choices. Magn Reson Med 79:1276–1292, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
12 August 2011 in Magnetic Resonance in Medicine
Brain images acquired at 3T often display central brightening with spatially varying tissue contrast, caused by inhomogeneity in the transmit radiofrequency fields used for excitation. Tailored radiofrequency pulses can provide mitigation of radiofrequency field inhomogeneity, but previous designs have been unsuitable for 3D imaging in rapid pulse sequences. This article presents a nonselective pulse design based on a short (1 ms) 3D spiral k‐space trajectory that covers low spatial frequencies. The resulting excitations are optimized to produce a uniform excitation within a specified volume of interest covering the whole brain. B1 mapping and pulse calculation times were reduced by optimizing in only five slices within the brain. The method has been tested with both single and parallel transmission: in phantom experiments, normalized root‐mean‐square error in excitation was 0.022 for single and 0.020 for parallel transmission. The corresponding results in vivo were 0.066 and 0.055 respectively. A pilot brain imaging study using the proposed pulses for excitation within the Alzheimer's disease neuroimaging initiative magnetization prepared rapid gradient echo (MP‐RAGE) protocol, yielded excellent image quality with improved signal to noise ratio in peripheral brain regions and enhanced uniformity of contrast compared with standard excitation. Greatest performance enhancement was achieved using parallel transmission, but single channel transmission offers significant improvement over standard excitation pulses. Magn Reson Med, 2012.