D. Borozenets

D. Borozenets

Auto-generated profile, based on publicly available information

D. Borozenets

D. Serikbayev East Kazakhstan Technical University

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
ZRZhenisgul Rakhmetullina
Zhenisgul Rakhmetullina
DBDavid Borozenets
David Borozenets
FAFarida Amenova
Farida Amenova
KAKarlygash Alibekkyzy
Karlygash Alibekkyzy
MBMadina Bazarova
Madina Bazarova
TKTalshyn Keribayeva
Talshyn Keribayeva
Reliable clinical information systems require not only correct numerical calculations but also robust input validation, consistent decision logic, and reproducible performance. This study evaluated the Acid–Base Balance Analysis module of Gasometry, a React/TypeScript web platform, using source-code inspection and browser-based testing of a local production build. A set of 160 synthetic scenarios comprised 120 numerical and 40 technical-input cases; additional experiments assessed 300 repeated executions, 20 cross-browser scenario pairs, and 480 load-test operations. The implemented potassium-inclusive anion-gap expression agreed with an independent decimal-arithmetic reference in all 120 numerical cases within 0.01 mmol/L, while decision-branch concordance was 119/120. However, none of 33 invalid inputs met the predefined strict rejection criterion, and varying pH and pCO₂ did not change terminal outcomes when electrolytes were held constant, revealing a control-flow defect. All 300 repeat executions were consistent, and 19/20 cross-browser pairs matched. Median and 95th-percentile interface-transition times were 1.60 and 2.40 ms, respectively. These findings demonstrate numerical reproducibility but identify input-validation and interpretation-logic weaknesses. The results constitute technical rather than clinical validation; software corrections and clinician-reviewed testing are required before clinical deployment.

29 July 2026 in Bulletin of Shakarim University. Technical Sciences
Verified
Journal Article
Open access
PDF file
IUIndira Uvaliyeva
Indira Uvaliyeva
ZRZhenisgul Rakhmetullina
Zhenisgul Rakhmetullina
STSh. Tezekpayeva
Sh. Tezekpayeva
DBDavid Borozenets
David Borozenets
ZNZh. Nurumov
Zh. Nurumov
This article presents a clinical decision support system for diagnosing acid–base balance disorders based on arterial blood gas (ABG) analysis using the Henderson–Hasselbalch equation. Considering the increasing requirements for accuracy and rapid clinical diagnostics, algorithm-based interpretation of ABG parameters has become highly relevant. The study aims to systematize the key blood gas indicators (рН, ???? ???? ???????? 2 , ???????????? 3 − , BE) and analyze their physiological relationships, as well as to develop a logical and mathematical model for automated classification of acid–base disorders. The proposed algorithm enables the identification of metabolic, respiratory, and mixed disturbances, taking compensatory mechanisms into account. The results demonstrate that the implementation of a computerized decision support model enhances diagnostic objectivity, reduces interpretation errors, and improves the quality of clinical decision-making.