Ivan Nunes Santos

Ivan Nunes Santos

Auto-generated profile, based on publicly available information

Ivan Nunes Santos

Universidade Federal de Uberlândia

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
BGBarbara Morais Gianesini
Barbara Morais Gianesini
ISIvan N. Santos
Ivan N. Santos
Paulo F. RibeiroPaulo F. Ribeiro
Paulo F. Ribeiro
The growing use of nonlinear devices has raised the harmonic levels in power systems. A challenging power quality problem is determining how much each installation contributes to the harmonic voltages measured at a point of common coupling so that the costs of mitigation solutions can be fairly divided. Currently, there is still no practical worldwide established method to solve this problem. The IEEE PES Task Force on Harmonic Modeling and Simulation developed a Benchmark Test System to support this line of research. Therefore, this study uses the IEEE PES Benchmark to evaluate and compare harmonic contribution determination (HCD) methods. To do so, this Benchmark Test System was implemented in MATLAB/Simulink and used to test five HCD methods proposed in the literature under different network operating cases, including cases with background distortions and resonance. The methods are the Voltage Harmonic Vector Method, the IEC Method, the Dominant Impedance Method, the Capacitor Switching Method, and the Harmonic Current Injection Method. It has been found that the HCD methods generally led to similar contribution percentages, proving the convergence of the methodologies. In addition, an analysis of the methods' sensitivity to input measurement errors was done.

1 May 2014
Verified
Conference Paper
Closed access
ISIvan Nunes Santos
Ivan Nunes Santos
MBMath Bollen
Math Bollen
Paulo F. RibeiroPaulo F. Ribeiro
Paulo F. Ribeiro
The increasing penetration of distributed generation with non-linear characteristics demands a clear methodology for determining the amount of generation that can be connected to the system without deteriorating the performance. This paper proposes a methodology for determining the hosting capacity regarding harmonic distortions. To exemplify an application of the proposed procedure, a simple case study is performed and analyzed.

1 October 2011
Verified
Conference Paper
Closed access
ISIvan Nunes Santos
Ivan Nunes Santos
JOJosé Carlos De Oliveira
José Carlos De Oliveira
JJJose Rubens Macedo Junior
Jose Rubens Macedo Junior
Considering the guidelines contained in documents such as the IEEE Standard 519 and IEC 61000-3-6 that includes, among other indexes of power quality, the thematic of the harmonic distortion, the mentioned text refers to issues associated with definitions, measuring procedures, reference values, etc. Taking under consideration these determinations, and recognizing that the mitigating solutions for the adequacy of performance indexes involve significant financial costs, the proposition of finding ways to determine the responsibility for possible violations of pre-established limits for harmonic distortion arises. Among the proposals found to detect the contribution portions coming from the supplier and the customer, it is noteworthy that, in general, the methodologies based on principles use the frequency domain harmonized with the superposition of effects. Despite the simplicity of this procedure, it is emphasized that it relies on measuring information and on the previous knowledge of the equivalent harmonic impedances of the utility and customer, whose information are of difficult access. In this context, this paper is focused on a feasibility proposition to solve the above mentioned difficulties in obtaining the percentage of responsibility between the parties.

12 January 2016 in Ciência & Engenharia
Verified
Journal Article
Closed access
ASArthur Costa de Souza
Arthur Costa de Souza
LILaura Elisa Issa
Laura Elisa Issa
FMFernando Cardoso Melo
Fernando Cardoso Melo
LUIZ CARLOS GOMES FREITASLUIZ CARLOS GOMES FREITAS
LUIZ CARLOS GOMES FREITAS
ISIvan Nunes Santos
Ivan Nunes Santos

26 October 2021 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Open access
PDF file
FPFabiana A. Pereira
Fabiana A. Pereira
SSSérgio F. de P. Silva
Sérgio F. de P. Silva
ISIvan N. Santos
Ivan N. Santos
One of the greatest challenges found in power quality has been, and still is, the establishing of a reliable noninvasive method for quantifying the harmonic contributions of an electric utility and a consumer at the point of common coupling (PCC). This difficulty arises from the fact that the harmonic distortions measured on the PCC are unidentifiable mixtures from both parties. Currently, some work has focused on exploring the use of blind source separation (BSS) techniques to promote the sharing of harmonic responsibilities in a noninvasive way. However, the usage of this methodology is very recent and still requires thorough evaluations, not only from the point of view of the BSS techniques available in the literature, but also from the perspective of the electrical power systems and the nature of their loads. Thus, seeking to contribute to the consolidation of the use of BSS techniques in the sharing of harmonic responsibilities, this work aimed to investigate the impact of the variation of harmonic current sources on the accuracy of BSS methods. In addition, three algorithms suitable for complex-valued signals were evaluated computationally and experimentally; the results obtained computationally were compared with the results of the method based on the covariance characteristic of the random vectors, and the experimental results was compared to that obtained through an invasive procedure.

1 January 2021
Verified
Conference Paper
Closed access
GTGiordanni Da Silva Troncha
Giordanni Da Silva Troncha
ISIvan Santos
Ivan Santos
ABArthur Fernando Bonelli
Arthur Fernando Bonelli