Ihor Matsyk

Ihor Matsyk

Auto-generated profile, based on publicly available information

Ihor Matsyk

Lviv Polytechnic National University

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2024 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
SSStanislav O. Sidnei
Stanislav O. Sidnei
OMOleh Myroshnyk
Oleh Myroshnyk
AKAndrii Kovalov
Andrii Kovalov
RVRoman Veselivskyi
Roman Veselivskyi
KHKostiantyn Hryhorenko
Kostiantyn Hryhorenko
IMIhor Matsyk
Ihor Matsyk
The object of this study is the fire resistance of reinforced concrete hollow slabs at the onset of the limit state of loss of integrity. The problem of accurate modeling of the formation and development of cracks in concrete was investigated. The paper reports an analysis of the results of the stress-strain state of a reinforced concrete hollow slab during fire exposure for devising a method for evaluating the fire resistance of such structures upon the onset of the limit state of loss of integrity. According to EN 1992-1-2, the determination of fire resistance of structures is provided by calculation methods, however, there is no such procedure for reinforced concrete hollow slabs. Many scientific works offer refined methods for evaluating only the loss of load-bearing and heat-insulating capabilities, leaving aside the issue of loss of integrity. Thus, this can lead to a biased evaluation of reinforced concrete hollow floor slabs according to the criterion of the limit state of loss of integrity, which in turn can put under a threat to the fire safety of buildings, which threatens the life and health of people. According to the results of the calculation, a parameter has been determined, according to which the onset of the limit state of fire resistance, in particular, the loss of integrity, was established. Summarizing the damage distributions, it was assumed that in the case of reaching the critical plastic deformation of 2.5e-3 in concrete finite elements, they are excluded from the general set of finite elements. Thus, in the case of the formation of through cracks, the removal of finite elements is taken as a parameter to identify the onset of the limit state of loss of integrity. According to the results of the computational experiment, it was established that through cracks in a fragment of a reinforced concrete hollow slab are formed in 44 min. According to the results of the research, the method of evaluating the fire resistance of such structures based on the onset of the limit state of loss of integrity has been substantiated. Such a method could be applied during design, which provides an opportunity to determine the limit of fire resistance in reinforced concrete hollow slabs

30 October 2024 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
SSStanislav O. Sidnei
Stanislav O. Sidnei
SGSerhii Gonchar
Serhii Gonchar
MZMaxim Zhuravskij
Maxim Zhuravskij
IMIhor Matsyk
Ihor Matsyk
INIhor Nozhko
Ihor Nozhko
VVViktor Vykhrystenko
Viktor Vykhrystenko
This paper reports a study aimed at assessing fire resistance of reinforced concrete ribbed slabs at the onset of integrity loss limit state. EN 1992-1-2 lacks calculation methodology for determining the limit of fire resistance of reinforced concrete slabs when the limit state of integrity loss occurs. Scientific works are focused on two limit states of fire resistance: load-bearing capacity and heat-insulating capacity. Experimental tests are criticized because of difficulties in registering signs of the onset of the limit state of loss of integrity, in particular due to the need to control the unheated surface of the ribbed plate during a fire under the action of mechanical load. Therefore, there is no calculation methodology for assessing the fire resistance of reinforced concrete ribbed slabs upon the onset of the limit state of loss of integrity. At the same time, to ensure the safe evacuation of people in the event of a fire, to prevent the spread of fire, as well as to carry out the effective work of rescuers, it is necessary to use building structures with guaranteed fire resistance classes. The paper reports the results of solving thermal engineering and static problems, which relate to the temperature distribution and stress-strain state of the investigated ribbed plate. Conducting research into the fire resistance of reinforced concrete ribbed slabs, taking into account the onset of the limit state of loss of integrity, made it possible to establish the dependence of the fire resistance limit of these structures on the loss of integrity on the level of applied mechanical load. The resulting dependence plot makes it possible to evaluate reinforced concrete ribbed slabs according to the criterion of the onset of the limit state of loss of integrity, which provides an opportunity to determine fire resistance more objectively