Methods for calculating the fire resistance of steel-reinforced concrete slabs made using profiled steel sheets under the influence of a standard temperature regime for more than 120 minutes are considered and analyzed. Research has been carried out to determine the heating parameters and the stress-strain state of steel-reinforced concrete slabs made using profiled steel sheets under fire conditions for more than 120 minutes. The results of this study allow to obtain indicators of temperature distribution for assessing the fire resistance of such structures for fire resistance classes above REI 120. Accordingly, the results obtained are a scientific basis for improving the existing method for calculating the fire resistance of steel-reinforced concrete slabs made using profiled steel sheets. The temperature distribution in the cross-section of structures was obtained using a general theoretical approach to solving the problem of heat conduction using the finite element method. Using the obtained temperature distributions, the parameters of the stress-strain state were determined based on the method of limiting states. To carry out the calculations, appropriate mathematical models were created that describe the effect of the standard temperature regime of a fire, to determine the temperature distribution at every minute in the sections of steel-reinforced concrete slabs with profiled steel sheets. A method is proposed for dividing the section into zones to take into account the decrease in the indicators of the mechanical properties of concrete and steel. A simplified method for the design assessment of steel-reinforced concrete slabs made using profiled steel sheets is proposed, which is consistent with the current EU standards and can be effectively used to analyze their fire resistance when establishing their compliance with the fire resistance class REI 120 and higher.
In this work, it is substantiated that it is possible to create a fire installation with parameters that will ensure higher environmental friendliness of the tests compared to large-sized furnaces. At the same time, its configuration will be universal, compact and capable of high reproducibility...
Fire tests of reinforced concrete floor slabs do not allow the detection of the onset of the boundary state due to loss of entirety because blocks are installed on the unheated surface to reproduce the design load. This prevents the formation of cracks through which toxic combustion products, smoke, and temperature spread can penetrate. Determining a building structure’s actual fire resistance limit was fixed at the onset of any fire resistance boundary state. It was proven that calculation methods for fire resistance assessment have significant advantages over experimental methods. To reduce the number of finite elements for a rational calculation of the fire resistance assessment of a reinforced concrete hollow core slab, a geometric model of 1/4 of this structure was built. The possibility of visualizing the studied structure at full scale was realized when obtaining the calculation results. The stress-strain state of the studied structure was evaluated based on the thermal and mechanical loading results applied to the reinforced concrete hollow core slab. Thus, the work’s objective was achieved based on the calculation experiments’ results. A methodology was developed for calculating the destruction of a reinforced concrete hollow core slab while assessing its fire resistance. Scientific fundamentals for determining the onset of the boundary state of loss of entirety were developed. The proposed methodology allowed for a reliable assessment of the fire resistance of such structures.
31 October 2023 in Eastern-European Journal of Enterprise Technologies
The object of research is the fire resistance of reinforced concrete ribbed slabs. The subject of research is the effect of the level of mechanical load on the fire resistance of the studied reinforced concrete ribbed slab under the influence of fire. Currently, the assessment of the fire resistance of such structures using the tabular method is significantly limited by certain geometric parameters of these plates. It is also not considered possible to apply the zone method, since reinforced concrete ribbed slabs consist of components that receive thermal effects according to various scenarios and geometric parameters, which is not taken into account in Eurocode 2. Experimental calculations carried out in the current work using a refined procedure involving the finite element method allow solving the actual scientific and technical problem related to the determination of the dependence of the fire resistance of these structures on the level of load applied. The calculation of the temperature spread over a reinforced concrete ribbed slab under the influence of the standard temperature regime of fire was carried out using convection and radiant heat exchange, which is recommended by Eurocode 2. The iterative implicit Newton-Raphson method was used to solve the mechanical problem. Evaluation of fire resistance of reinforced concrete ribbed slabs was carried out according to the onset of signs of the limit state of fire resistance due to the loss of load-bearing capacity. According to the results, it was established that at 100 % load level of the structure under investigation, the critical deflection of more than 268 mm and the rate of growth of deformation exceeding 18 mm/min were recorded simultaneously on minute 43.9. According to the results of the research, the regularity of the limit of fire resistance of reinforced concrete ribbed slabs from the level of the applied mechanical load was established. This will make it possible to design and build buildings and structures using the specified building structures with guaranteed fire resistance classes, which improves the level of safety for people at the facilities