Anton Makarenko

Anton Makarenko

Auto-generated profile, based on publicly available information

Anton Makarenko

Scientific and Technical Complex “E.O. Paton Electric Welding Institute“ of the National Academy of Sciences of Ukraine, Kyiv, Ukraine

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2024 in Nuclear and Radiation Safety
Verified
Journal Article
Open access
PDF file
АMА. Makarenko
А. Makarenko
MCM. Chaikovskyi
M. Chaikovskyi
OMO. Mazurok
O. Mazurok
VZV. Zuyok
V. Zuyok
OMO. Mykhaylenko
O. Mykhaylenko
This paper presents the main results of strength calculations to justify the integrity of structural elements of the control rods and rod cluster control assemblies under static and dynamic loads in various (all possible) operating modes of rod cluster control assemblies, with the mechanical properties of the material after neutron irradiation, in order to lifetime extend their lifetime. The presented results of calculations of the stress-strain state of rod cluster control assembly elements indicate that the strength conditions are met under the operating modes considered in this paper (including the maximum design basis earthquake). The maximum stresses occur in the joint zone of the cladding with the upper end element, and the corresponding minimum value of the strength factor is 1.04. The obtained stress values in the control rods and the rod cluster control assembly spider do not exceed the yield strength of the material (RT0.2 = 245 MPa and RT0.2 = 167 MPa, respectively), which does not result in residual deformations. The results of the cyclic strength calculation show that the requirements for cyclic strength are met, the maximum predicted damage is only 5.82 × 10-02 for the control rods and 4.27 × 10-07 for the spider. Consequently, this guarantees the structural integrity of the control rods and rod cluster control assemblies at their extended lifetime. The safe operation (lifetime) of the rod cluster control assemblies currently loaded in VVER‑1000 reactors at Ukrainian NPPs was extended basing on the above justifications and positive results of strength calculations, assuming that fast neutron fluence (E > 0.1 MeV) does not exceed 3.4 × 1022 n/cm2, which, according to the previously performed neutron calculations, corresponds to the lifetime in the manual and automatic control groups up to 38,000 effective hours, in reactor scram groups – approximately up to 113,500 effective hours.

23 December 2024 in Nuclear and Radiation Safety
Verified
Journal Article
Open access
PDF file
OMO. Mazurok
O. Mazurok
VIV. Ivanov
V. Ivanov
OGO. Godun
O. Godun
VZV. Zuyok
V. Zuyok
AMA. Makarenko
A. Makarenko
The uninterrupted operation of Ukrainian NPPs depends not only on timely delivery of fresh fuel, but also on the supply of a number of other critical core elements. One of these critical elements is control rods, which have their own lifetime and need to be replaced on a regular basis. If the diversification of nuclear fuel suppliers has been ongoing since the early 2000s [1], the diversification of control rods was at the initial stage at the beginning of the full-scale invasion and its completion requires some time to conduct the relevant tests and trial operation in the reactor core. For temporary meeting the NPP need for control rods, it was decided to justify lifetime extension for them by determining the residual lifetime. Control rod lifetime extension is based on the determination of the residual lifetime using an approach that takes into account control rod actual position during all fuel campaigns in which the control rods were operated. Excessive conservatism was laid due to the assumption that the immersion of the 10th working group in the core during all fuel campaigns is 70 %, but the actual position is 85–90 %. To reduce conservatism, it is necessary to take into account the actual position of the emergency control groups during all fuel campaigns in which the control rods were part of the control group that requires a large number of neutronic calculations to determine the neutron fluence and absorbing element burnup (boron-10). The obvious approach to determining the fluence of fast neutrons and boron burnup in absorbing elements is currently the use of the Monte Carlo method, which allows modeling neutron transport without any serious assumptions and approximations of the computational model, and, accordingly, present the most accurate results. The main disadvantage of Monte Carlo codes is that the simulation of complex systems is a long-term computational process, which can become a limiting factor. Considering the need to take into account the actual operation schedule of each control rod, the application of the Monte Carlo method to justify the operability in the lifetime extension for control rods is extremely problematic. The approach to neutronic calculations using the HELIOS code is proposed in the paper in terms of determining the fluence of fast neutrons and burnup of the boron-10 isotope in absorbing elements. The approach is based on the application of the neutron transport solution in two-dimensional geometry based on the method of the first collision probability and the subsequent synthesis of two- and one-dimensional neutron flux density distributions. The implemented approach is characterized by an accuracy comparable to the Monte Carlo method but is much more efficient in terms of computer time spent for calculations, which allows a large amount of calculations to be performed to justify the lifetime extension for each individual control rod, taking into account the real history of operation.

8 December 2025 in East European Journal of Physics
Verified
Journal Article
Open access
VZValeriy Zuyok
Valeriy Zuyok
OMOleksandr Mazurok
Oleksandr Mazurok
VZVolodymyr Zigunov
Volodymyr Zigunov
BLBohdan Lankov
Bohdan Lankov
ADAlbert Dzhamirzoiev
Albert Dzhamirzoiev
OGOleg Godun
Oleg Godun
The specific energy release in the structural materials of the absorber assembly (control part of the accident control assembly – ACA, also known as the shim assembly) has been calculated. It depends on the power of the fixed fuel assemblies (FAs) in adjacent cells. The value of the energy release is 17.5 W/cm3 on the most loaded section of the boron absorber insert for an average Kq=1.28 over sectors. The total energy release in the structural materials of the absorber assembly, in the coolant, and in the connecting bar material is 229 kW for fully inserted controls and 64 kW for controls lifted up by 154.8 cm from the core bottom. The surface temperature distribution in the absorber insert along the absorber assembly height is conservatively calculated based on the total energy release in the absorber insert material and the amount and rate of coolant flow through it. At a coolant temperature around the absorber insert corresponding to the maximum coolant heating in adjacent fixed FAs (46.6 °C), and in the absence of axial heat exchange, the maximum surface temperature of the absorber insert for fully inserted controls will be 312.7 °C (outer surface), and for controls lifted from the core bottom to 154.8 cm – 317.1 °C (inner surface), giving a margin to saturation of 14.3 °C and 9.9 °C, respectively, at a coolant saturation temperature of 327 °C. In the most conservative case considered in this paper, the maximum surface temperature of the absorber insert is lower than the coolant's saturation temperature. This indicates the absence of bulk and surface boiling of the coolant under operation of the most energy-loaded component, i.e., the absorber insert of the absorber assembly, meaning that the structural components of the absorber assembly will be reliably cooled in the VVER-440 reactor core.