1 October 2024 in Indonesian Journal of Electrical Engineering and Computer Science
Electronic devices and loads are very sensitive to the voltage disturbances like voltage sag and voltage swell. Significant financial losses and safety issues may emerge from voltage sags and interruptions, which can be caused by variables such as system breakdowns and load changes. In order to protect against voltage fluctuations and keep vital loads running, dynamic voltage restorers (DVRs) have become more popular. To mitigate the voltage disturbances, an interlined DVR (IDVR) using a Z-source inverter (ZSI) is developed to protect the sensitive devices and loads. Back-to-back DVR connects the distributed feeders with a common direct current (DC) link. The IDVR compensates for the sag voltage and supplies the energy to control the power flow. In addition, proposed a modified synchronous reference frame (MSRF)/direct quadrature theory, hysteresis controller, and proportional integral (PI) controller, which provides the required amount of control signals for a ZSI and voltage source inverter (VSI). MATLAB/Simulink validated the simulation results. The experimental findings show that the suggested system can be implemented successfully and is effective at reducing voltage dips and interruptions, allowing crucial loads to keep operating consistently and without interruption in residential as well as commercial environments.
14 July 2020 in Transactions of the Institute of Measurement and Control
This paper proposes an intelligent technique-based optimal controller for harmonics mitigation to maintain the power quality in renewable energy source (RES)-based distribution systems. The proposed intelligent technique is the joint execution of both the fractional-order proportional integral controller and moth-flame optimization with random decision forest. In the proposed approach, moth-flame optimization optimizes the dataset of fundamental and harmonic loop parameters such as terminal voltage and direct current voltage present in the hybrid shunt active power filter. The dataset is generated based on the linear and nonlinear load variation and parameter variation of the renewable energy sources, subject to the minimum error objective function. Based on the accomplished dataset, random decision forest accurately predicts the parameters and produces optimized control signals. The proposed technique guarantees the system with less complexity for the harmonics mitigation of the power quality event and hence the accuracy of the system is raised. Then, the proposed model is executed in the Matrix Laboratory/Simulink working platform and the execution is assessed with the existing techniques. The simulation analysis of the proposed approach is tested using the six test cases with various combinations of nonlinear loads. In all the test cases, the performance of various system parameters, such as source current with and without filter, source voltage, hybrid shunt active power filter current, load current and voltage, is analysed. Furthermore, the total harmonic distortion at different load ratings is also examined.