Albert Shin

Albert Shin

Auto-generated profile, based on publicly available information

Albert Shin

University of Washington

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 February 2025 in bioRxiv
Verified
Preprint
Open access
PDF file
JBJean Berthier
Jean Berthier
JTJodie C. Tokihiro
Jodie C. Tokihiro
AMAnika M McManamen
Anika M McManamen
TCTj Caira
Tj Caira
ASAlbert Shin
Albert Shin
EBErwin Berthier
Erwin Berthier
The Lucas-Washburn-Rideal law is commonly applied to describe capillary flow dynamics in closed or open channels, microporous media, such as paper pads and fiber threads or even granulous soil. It assumes a viscous flow regime where capillary forces are counteracted by friction with the solid structure, a valid assumption given the small flow velocities and device dimensions. However, scenarios exist outside the viscous regime, where inertial effects become significant, meaning capillary and friction forces do not fully balance. One well-documented case is the transient inertial regime at the onset of capillary motion. With the advancement of capillary devices, other configurations also raise the possibility of inertia influencing flow behavior. This study introduces a criterion to identify inertial contributions in capillary-driven flows in spatially varying geometries within open or closed channels and demonstrates how the Bosanquet equation can account for inertial effects in rectangular open-channel configurations.

14 April 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
ALAriel Lin
Ariel Lin
LMLaura A. Milton
Laura A. Milton
DCDamon Wing Hey Chan
Damon Wing Hey Chan
NGNidhi Ghadge
Nidhi Ghadge
JTJodie C. Tokihiro
Jodie C. Tokihiro
ATAshleigh B. Theberge
Ashleigh B. Theberge
Stereolithography (SLA) 3D printing has become increasingly popular for fabricating microfluidic devices, with applications including hydrogel patterning and tissue modeling. In open-channel systems with surface tension-driven flow, 3D-printer-induced discrepancies in channel surface texture can significantly impact fluid flow and device performance. While previous work has focused on comparing different 3D printing methods for microchannel fabrication, the effect of device orientation during SLA printing on microchannel morphology and capillary-driven flow has not been systematically evaluated. Furthermore, there is minimal research elucidating the influence of channel surface texture on the flow of biologically relevant hydrogel precursors commonly used in organ-on-a-chip applications. Herein, we investigated the impact of print orientation on channel morphology, fluid wetting behavior, and fluid flow by comparing laser SLA-based parts where the length of the channel was tilted at 0°, 15°, 45°, or 90° during printing. We demonstrated that channel floor surface texture is greatly affected by print orientation: the highest axial surface roughness was measured in 15° printed channels, and the highest axial surface tortuosity–which describes the real length along the surface–was measured in 45° printed channels. Print angles of 15° and 45° also resulted in asymmetric roughness of the channel floor, which caused asymmetric wetting of glycerol solution. Surface tension-driven flow of glycerol solution, agarose precursor solution, and collagen precursor solution was affected by print orientation, in which the 45° printed flow devices had slowest flow for all test fluids. Root mean square roughness was not a reliable predictor of slower flow; instead, surface tortuosity should be considered. Potential alternatives to better theoretically model how print angle-induced surface texture affects open-channel flow are discussed as well. These findings provide a framework of fabrication considerations for laser SLA printing of open microchannels that can also be applied to other layer-by-layer, vat photopolymerization-based 3D printing technologies.

26 June 2026 in bioRxiv
Verified
Preprint
Open access
TCTj Caira
Tj Caira
JTJodie Tokihiro
Jodie Tokihiro
ASAlya Shaposhnikov
Alya Shaposhnikov
JWJamison M. Whitten
Jamison M. Whitten
XSXiaojing Su
Xiaojing Su
JBJean Berthier
Jean Berthier
Control of fluids is a hallmark of microfluidic systems and fundamental for the successful application of microfluidic devices. Trigger valves use geometric features to autonomously control the release of fluids in microfluidic devices. Our previous work has adapted geometries used in closed trigger valve systems to enable use in open systems, allowing for open microfluidic devices with up to three trigger valves. Here, we focus on the parallel co-flows produced by sequential release of trigger valves and present a model that predicts their layer widths as a function of the geometric characteristics of the different side channels of each trigger valve. We show layered co-flows with widths as low as 50 microns. Additionally, we expand the use of trigger valves in open microfluidic devices by incorporating 1) varied step heights, 2) devices with up to seven trigger valves, and 3) use of varied fluids and plastics including an application with fibroblasts in collagen. To validate the implementation and use of these trigger valves in open systems, we have developed a theoretical framework to compare predicted outcomes (i.e., fluid travel distance, velocity, and layering width) with our experimental values. This theoretical work offers applications in various fields, including hydrogel patterning for 3D cell culture, organ-on-a-chip models, at-home sample preparation, and autonomous microfluidic systems for biosensing.

14 October 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
CPCorinne Pierce
Corinne Pierce
KSKezia Suryoraharjo
Kezia Suryoraharjo
IRIngrid H. Robertson
Ingrid H. Robertson
XSXiaojing Su
Xiaojing Su
DHDaniel B. Hatchett
Daniel B. Hatchett
LSLydia L. Sohn
Lydia L. Sohn
Extracellular vesicles (EVs) are promising biomarkers for disease detection using a ‘liquid biopsy’ approach, in which they are enriched and analyzed directly from biofluids. However, implementing EV biomarker technologies in the clinic remains limited by the need for practical and patient-centric biofluid collection methods that are compatible with downstream EV processing and analysis. While saliva offers a non-invasive source of EVs, its complexity and heterogeneity—cells, debris, and other non-EV proteins—can present hurdles when using traditional analytical platforms. Here, we present the CandyCollect, a lollipop-inspired sampling device with open microfluidic channels, as a patient-friendly approach for rapid salivary EV capture. CandyCollect simplifies sample preparation by effectively pre-concentrating EVs in oxygen-plasma treated open microfluidic channels. In this proof-of-principle study, we show that following a 3-5 minute-oral sampling period, EVs collected by the CandyCollect can be released with high purity within minutes and subsequently quantified and analyzed for cargo content. We observed consistent EV capture across repeated collections within individuals and expected variability across healthy participants. Additionally, single and pooled collections of EVs from a healthy participant resulted in a concordant protein profile. Overall, the CandyCollect is a new platform for rapid, non-invasive salivary EV collection and analysis for clinical diagnostics.